La Valle Waterworks
What EPA’s and Wisconsin’s records show in this utility’s water: nitrate, arsenic and other regulated chemicals; lead and copper; and violations since 2016, with the certification that handles each result.
- Serves
- 365 people
- Connections
- 135
- Water source
- Groundwater
- Based in
- La Valle, WI
- County
- Sauk
- Owner
- Local government
- Hardness
- Hard
The ZIP code it serves
The short answer
2 results are above the health goal. The worst: Lead, above the health goal. 6 health-based violations since 2016.
What handles itWhat was found
Lead and copper: EPA SDWIS monitoring periods ending 2002 to 2023.
Nitrate, fluoride, haloacetic acids (HAA5), total trihalomethanes (TTHM), arsenic and chromium (total): Wisconsin’s own results, samples taken from Jan. 21, 2020 to Aug. 10, 2026, with EPA’s 2012 to 2019 file for earlier years.
Uranium: EPA’s compliance monitoring file, samples taken from March 22, 2017 to July 15, 2019. Newer results are in the utility’s annual water quality report.
Above the health goal2
Lead
Comes from pipes, often your own
1.8ppb
90th percentile, 2023
In the latest period, 9 in 10 homes sampled were at or below 1.8 ppb, below EPA’s action level of 15 ppb. The action level drops to 10 ppb on Nov. 1, 2027. EPA’s health goal for lead is zero.
What handles it
- NSF/ANSI 53 look for “Lead Reduction”
- NSF/ANSI 58 look for “Lead Reduction”
Uranium
Comes from the source
0.09ppb
Highest yearly average, 2017 to 2019
2019, one sample: 0.08 ppb
Averaged by year, the highest was 0.09 ppb, in 2018: below EPA’s legal limit of 30 ppb, but above its health goal of zero. In 2019, the latest year on file, its one sample was 0.08 ppb.
What handles it
- NSF/ANSI 58 look for “Uranium”
Below EPA’s limits4
Nitrate
Comes from the source
5.0ppm
Highest sample; found in 24 of 24
2026, one sample: 1.1 ppm
The highest sample, in 2020, was 5.0 ppm, below EPA’s legal limit of 10 ppm. In 2026, the latest year on file, its one sample was 1.1 ppm. Earlier, from 2012 to 2019, EPA’s file shows a highest sample of 6.4 ppm, in 2019.
What handles it
- NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
- NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”
Fluoride
Forms or is added in treatment
0.85ppm
Highest yearly average, 2020 to 2026
2026, one sample: 0.11 ppm
Averaged by year, the highest was 0.85 ppm, in 2020, below EPA’s legal limit of 4.0 ppm. Its highest single sample was 3.4 ppm. In 2026, the latest year on file, its one sample was 0.11 ppm. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 0.39 ppm, in 2014.
What handles it
- NSF/ANSI 58 look for “Fluoride Reduction”
- NSF/ANSI 53 look for “Fluoride”
Haloacetic acids (HAA5)
Forms or is added in treatment
9.4ppb
Highest yearly average, 2020 to 2026
Averaged by year, the highest was 9.4 ppb, in 2026, below EPA’s legal limit of 60 ppb. That was also the latest year on file. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 5.0 ppb, in 2017.
What handles it
No certification claim covers this compound yet.
Total trihalomethanes (TTHM)
Forms or is added in treatment
8.3ppb
Highest yearly average, 2020 to 2026
Averaged by year, the highest was 8.3 ppb, in 2026, below EPA’s legal limit of 80 ppb. That was also the latest year on file. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 4.5 ppb, in 2014.
What handles it
- NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
- NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”
2 compounds tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
- Arsenic
- Chromium (total)
What handles it
A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box. Wording varies a little: NSF writes “Lead Reduction,” WQA just “Lead.”
- NSF/ANSI 53
Claim: Lead Reduction
For: Lead
- NSF/ANSI 58
Claims: Lead Reduction, Uranium
For: Lead, Uranium
At the tap, or for the whole house?
Lead and copper usually come from pipes and fixtures inside or near your home. A whole-house system sits where water enters, so it cannot catch what your own plumbing adds after it. For those, the filter that counts is the one at the tap. How whole-house systems compare.
Filters with those claims on a certifier’s listing
Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money
Brita Tahoe Pitcher with Elite Filter (OB60, OB06)
Pitcher
- WQA listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 401checked Oct. 13, 2026
- IAPMO listing:NSF/ANSI 53checked Oct. 13, 2026
Certified for: Lead
Brita Everyday Pitcher with Elite Filter (OB46, OB06)
Pitcher
- WQA listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 401checked Oct. 13, 2026
Certified for: Lead
PUR PLUS 11-Cup Pitcher (PPT111W)
Pitcher
- NSF listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 401checked Oct. 4, 2026
- WQA listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 401checked Oct. 4, 2026
- IAPMO listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 401checked Oct. 4, 2026
Certified for: Lead
ZeroWater 10 Cup Pitcher (ZP-010)
Pitcher
- IAPMO listing:NSF/ANSI 42NSF/ANSI 53checked Oct. 4, 2026
Certified for: Lead
Culligan 10-Cup Pitcher with ZeroWater Technology (ZEROP10)
Pitcher
- IAPMO listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 401checked Oct. 9, 2026
Certified for: Lead
Hardness
Hard, typically 143 mg/L (8.3 grains per gallon), across 2 sampling points, 2017 to 2026.
Hardness is calcium and magnesium. EPA sets no limit for it: it shows up as scale on fixtures and in water heaters, and as soap that won’t lather. USGS calls water above 60 mg/L moderately hard, above 120 hard and above 180 very hard.
Violations since 2016
| Contaminant or rule | Type | Period | Measured | Status |
|---|---|---|---|---|
| Benzene | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | Jan. 1, 2021 to March 31, 2021 | 23.4 UG/L | Resolved |
| Benzene | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | Oct. 1, 2020 to Dec. 31, 2020 | 55.7 UG/L | Resolved |
| Benzene | A sample was above the legal limit, for a contaminant judged one sample at a time.EPA: Maximum Contaminant Level Violation, Single Sample | Oct. 1, 2020 to Dec. 31, 2020 | 112 UG/L | Resolved |
| Benzene | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | July 1, 2020 to Sept. 30, 2020 | 37.7 UG/L | Resolved |
| Benzene | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | April 1, 2020 to June 30, 2020 | 20.6 UG/L | Resolved |
| Benzene | A sample was above the legal limit, for a contaminant judged one sample at a time.EPA: Maximum Contaminant Level Violation, Single Sample | Jan. 1, 2020 to March 31, 2020 | 37.3 UG/L | Resolved |
| Health-based violations only. Resolved and archived mean the utility returned to compliance or the state closed the record. 1 monitoring or reporting violation not shown. | ||||
What this report can’t tell you
Everything else. Nitrate, fluoride, haloacetic acids (HAA5), total trihalomethanes (TTHM), arsenic and chromium (total) results here are Wisconsin’s own from 2020 on, with EPA’s national file for 2012 to 2019. Uranium comes from EPA’s file alone, which ends in 2019. La Valle Waterworks’s own annual report, which it must send you every year, has newer results for those and the contaminants this page does not show.
Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.
What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.
Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; Wisconsin’s results run from Jan. 21, 2020 to Aug. 10, 2026; EPA’s compliance samples are from March 22, 2017 to July 15, 2019.
Testing your own tap
The 3 labs Wisconsin certifies closest to the area La Valle Waterworks serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.
Pure Water Labs, LLC
Reedsburg, WI · about 8 miles
Certified for bacteria
Pure Water Labs, LLC
Lodi, WI · about 8 miles
Certified for bacteria
CT Laboratories
Baraboo, WI · about 22 miles
Certified for bacteria, nitrate, lead and copper, metals, minerals and other inorganics, organic chemicals, disinfection byproducts
Wisconsin State Laboratory of Hygiene: Well water test kits ordered by phone and shipped free; you pay to mail the sample back, and the lab bills you after testing. Tests run from bacteria alone to a homeowner package covering bacteria, nitrate, fluoride, metals, hardness, volatile organic compounds and atrazine. Bacteria is $35, nitrate $35, lead $38, and the homeowner package $450, as of July 1, 2026. Public Environmental and Water Testing Prices, Wisconsin State Laboratory of Hygiene.
All 156 certified labs for WisconsinSources
- EPA UCMR 5 occurrence data, file of Oct. 15, 2026
- EPA SDWA bulk download (SDWIS federal data), 2026 Q3
- Wisconsin Department of Natural Resources, Drinking Water Program, results from Jan. 2, 2020 to Oct. 5, 2026, read Oct. 8, 2026
- EPA Six-Year Review 4 compliance monitoring data, 2012 to 2019, file of Feb. 5, 2024
- Certified labs: Wisconsin DNR and DATCP, certified and approved drinking water laboratories, read Oct. 10, 2026; distances from the Census 2020 ZIP code tabulation area gazetteer
- Hardness: Wisconsin Department of Natural Resources, Drinking Water Program, results from March 22, 2017 to May 11, 2026, read Oct. 10, 2026
- Limits and goals: each contaminant’s page, with its EPA source.
- How this page is built: methodology.
PWSID WI1570113. Rebuilt from EPA data on Oct. 18, 2026.
What to do next
- Read up on the 2 results above a lineWhat each one does to health, where it comes from, and the certification claim that addresses it.Start with Lead
- Get the utility’s own reportLa Valle Waterworks must send you a water quality report every year. It covers contaminants this page does not show, and has newer results than EPA’s national file for the ones here that come from it.How to read it
- Test your own tap for leadYour service line, solder and fixtures decide the lead at your faucet, not the utility’s average.Lead in your water: what to do
- Compare certified filtersWhat the filters certified for these results cost over five years, cartridges included.Compare five-year costs