Skip to content
TapBuff

Hca Hazleton Division

EPA’s and Pennsylvania’s records have results for 38 contaminants in its water; 4 were found.

Serves 45,000 people · Surface water · Hazleton, PA · Hardness: soft

Serves
45,000 people
Connections
15,152
Water source
Surface water
Based in
Hazleton, PA
County
Luzerne
Owner
Local government
Hardness
Soft
The 11 ZIP codes it serves

18201, 18202, 18216, 18221, 18223, 18224, 18225, 18230, 18234, 18239, 18255

The short answer

None of the results here is above a limit in force today. That covers PFAS and lithium; nitrate, arsenic and other regulated chemicals; and lead and copper, not everything. No health-based violations on file since 2016.

What was found

Where these results come from, and when

PFAS: Pennsylvania’s own results under its PFAS rule, entry point samples taken from Jan. 19, 2024 to March 17, 2026, with EPA’s UCMR 5 samples, 2024, as the earlier record.

Lithium, and PFAS Pennsylvania didn’t test: EPA UCMR 5, samples taken from Jan. 19 to Oct. 18, 2024.

Haloacetic acids (HAA5), total trihalomethanes (TTHM), fluoride, nitrate, arsenic, chromium (total) and uranium: Pennsylvania’s own results, samples taken from Feb. 20, 2020 to Aug. 20, 2026, with EPA’s 2012 to 2019 file for earlier years.

What the lines mean
Legal limit (MCL):
Enforceable. The most a utility may deliver.
Health goal (MCLG):
Not enforceable. The level with no expected risk, with a margin of safety.

PFAS: None of the six PFAS in EPA’s 2024 drinking water rule was found in this utility’s samples. None of the other 23 PFAS tested for was found either.

Below EPA’s limits, 4 results

Legal limit (MCL):
Enforceable. The most a utility may deliver.
Haloacetic acids (HAA5), Legal limit 60 ppb; highest yearly average 45.4 ppb

Highest yearly average, 2020 to 2026 · 2026 average: 22.9 ppb · Forms or is added in treatment

Averaged by year, the highest was 45.4 ppb, in 2024, below EPA’s legal limit of 60 ppb. Its highest single sample was 101 ppb. In 2026, the latest year on file, its 12 samples averaged below the limit. EPA recorded no violation for haloacetic acids (HAA5) at this utility since 2020.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 48.7 ppb, in 2018.

What handles it

No certification claim covers this compound yet.

About haloacetic acids (HAA5)
Total trihalomethanes (TTHM), Legal limit 80 ppb; highest yearly average 43.1 ppb

Highest yearly average, 2020 to 2026 · 2026 average: 29.4 ppb · Forms or is added in treatment

Averaged by year, the highest was 43.1 ppb, in 2024, below EPA’s legal limit of 80 ppb. Its highest single sample was 79.5 ppb. In 2026, the latest year on file, its 12 samples averaged below the limit.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 53.7 ppb, in 2018.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”
About total trihalomethanes (TTHM)
Fluoride, Legal limit 4.0 ppm; highest yearly average 0.31 ppm

Highest yearly average, 2020 to 2026 · 2026: not found · Forms or is added in treatment

Averaged by year, the highest was 0.31 ppm, in 2024, below EPA’s legal limit of 4.0 ppm. Its highest single sample was 0.61 ppm. In 2026, the latest year on file, it wasn’t found in any of its three samples.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 0.4 ppm, in 2019.

What handles it

About fluoride
Nitrate, Legal limit 10 ppm; highest 0.48 ppm

Highest sample; found in 16 of 27 · 2026 average: 0.16 ppm · Comes from the source

The highest sample, in 2026, was 0.48 ppm, below EPA’s legal limit of 10 ppm. That was also the latest year on file, and its three samples averaged below the limit.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest sample of 0.26 ppm, in 2019.

What handles it

  • NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
  • NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”
About nitrate
Pennsylvania utilities above EPA’s PFAS limits⁠
34 compounds tested and not foundIncluding all six PFAS in EPA’s 2024 rule. Below the reporting level in every sample. Not found is not the same as zero.

From routine monitoring

  • Arsenic
  • Chromium (total)
  • Lead
  • Uranium

PFAS, from Pennsylvania’s own monitoring

  • HFPO-DA (GenX)
  • PFBS
  • PFHxS
  • PFNA
  • PFOA
  • PFOS

From EPA’s UCMR 5 sampling

  • 11Cl-PF3OUdS
  • 4:2 FTS
  • 6:2 FTS
  • 8:2 FTS
  • 9Cl-PF3ONS
  • ADONA
  • Lithium
  • NEtFOSAA
  • NFDHA
  • NMeFOSAA
  • PFBA
  • PFDA
  • PFDoA
  • PFEESA
  • PFHpA
  • PFHpS
  • PFHxA
  • PFMBA
  • PFMPA
  • PFPeA
  • PFPeS
  • PFTA
  • PFTrDA
  • PFUnA

Violations since 2016

No health-based violations on file with EPA since 2016. There are 47 monitoring or reporting violations: a sample missed, late or not reported. EPA’s file runs to 2026 Q3, so a notice your utility sent since then may not be here yet.

Hardness

Soft, 16 mg/L (0.9 grains per gallon), at its one sampling point, 2020 to 2023.

Hardness is calcium and magnesium. EPA sets no limit for it: it shows up as scale on fixtures and in water heaters, and as soap that won’t lather. USGS calls water above 60 mg/L moderately hard, above 120 hard and above 180 very hard.

Disinfectant

Hca Hazleton Division reported disinfecting with chlorine, not chloramine, at its one sampling point, in its 2024 sampling for EPA. It also reported chlorine dioxide.

What that means

Chlorine leaves water that sits out for a few days, CDC says. A filter certified for it carries a chlorine claim under NSF/ANSI 42; a shower filter, a free chlorine claim under NSF/ANSI 177. This is what the utility reported for that sampling. Its annual water quality report says what it uses now.

What this report can’t tell you

  • Everything else. Haloacetic acids (HAA5), total trihalomethanes (TTHM), fluoride, nitrate, arsenic, chromium (total) and uranium results here are Pennsylvania’s own from 2020 on, with EPA’s national file for 2012 to 2019. Hca Hazleton Division’s own annual report, which it must send you every year, has the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 samples are from Jan. 19 to Oct. 18, 2024; Pennsylvania’s results run from Feb. 20, 2020 to Aug. 20, 2026; Pennsylvania’s PFAS results run from Jan. 19, 2024 to March 17, 2026.

Testing your own tap

Hca Hazleton Division’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab Pennsylvania certifies.

What to test for at your tap

  • Lead and copper. Both come mostly from a building’s own service line, solder and faucets, so a utility’s numbers can’t tell you yours. Hca Hazleton Division’s latest lead sampling in EPA’s records, 2025, had a 90th percentile of 0 ppb across the homes it sampled. The action level is 15 ppb, dropping to 10 ppb in November 2027, and EPA’s health goal for lead is zero. About lead.
The 3 labs Pennsylvania certifies closest to the area Hca Hazleton Division serves, or a kit by mail

The 3 labs Pennsylvania certifies closest to the area Hca Hazleton Division serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

  • HawkMtn Labs Inc

    Hazle Township, PA · about 6 miles

    Certified for bacteria, nitrate, lead and copper, metals, minerals and other inorganics, organic chemicals, disinfection byproducts, radioactivity

    (570) 455-6011

  • A E Kirby Memorial Health Center

    Wilkes-Barre, PA · about 19 miles

    Certified for bacteria, nitrate, lead and copper, metals, minerals and other inorganics

    (570) 822-4278

  • Microbac Laboratories, Inc. - Pittston

    Pittston, PA · about 25 miles

    Certified for bacteria, nitrate, lead and copper, metals, minerals and other inorganics, organic chemicals, disinfection byproducts

    (570) 348-0775

All 108 certified labs for Pennsylvania⁠

Or test by mail

Tap Score sells lab tests as kits you fill at your tap and mail back. The sample goes to Tap Score’s lab, not one near you, so check that Pennsylvania certifies it for the test you want.

  • Tap Score

    Return shipping included.

    Tap Score says each kit ships to “an accredited laboratory” but doesn’t name it, so TapBuff can’t check it against Pennsylvania’s list.

Prices from Tap Score’s own store on Oct. 22, 2026.

What to do now

Sources

PWSID PA2408001. Rebuilt from EPA data on Oct. 25, 2026.