Skip to content
TapBuff

Spv Water Company

What EPA’s and California’s records show in this utility’s water: nitrate, arsenic and other regulated chemicals; lead and copper; and violations since 2016, with the certification that handles each result.

Serves
211 people
Connections
73
Water source
Groundwater
Based in
Valencia, CA
County
Los Angeles
Owner
Private
Hardness
Very hard
The ZIP code it serves

91390

The short answer

1 result is above the health goal. The worst: Uranium, above the health goal. No health-based violations on file since 2016.

What handles it

What was found

Uranium, nitrate, fluoride, chromium (total), arsenic, haloacetic acids (HAA5) and total trihalomethanes (TTHM): California’s own results, samples taken from Jan. 8, 2020 to April 8, 2026, with EPA’s 2012 to 2019 file for earlier years.

Above the health goal1

Uranium

Comes from the source

Above the health goal

5.6ppb

Highest yearly average, 2021 to 2026

2026 average: 5.1 ppb

Averaged by year, the highest was 5.6 ppb, in 2024: below EPA’s legal limit of 30 ppb, but above its health goal of zero. Its highest single sample was 10.9 ppb. In 2026, the latest year on file, its four samples averaged 5.1 ppb. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 7.3 ppb, in 2014.

What handles it

Below EPA’s limits3

Nitrate

Comes from the source

Below EPA’s limits

8.8ppm

Highest sample; found in 76 of 76

2026 average: 6.6 ppm

The highest sample, in 2022, was 8.8 ppm, below EPA’s legal limit of 10 ppm. In 2026, the latest year on file, its eight samples averaged 6.6 ppm. Earlier, from 2012 to 2019, EPA’s file shows a highest sample of 10.0 ppm, in 2012.

What handles it

  • NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
  • NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”

Fluoride

Forms or is added in treatment

Below EPA’s limits

0.57ppm

Highest yearly average, 2021 to 2024

Averaged by year, the highest was 0.57 ppm, in 2024, below EPA’s legal limit of 4.0 ppm. Its highest single sample was 0.7 ppm. That was also the latest year on file. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 3.1 ppm, in 2018.

What handles it

Chromium (total)

Comes from the source

Below EPA’s limits

14ppb

Highest yearly average, 2021 to 2024

Averaged by year, the highest was 14 ppb, in 2024, below EPA’s legal limit of 100 ppb. That was also the latest year on file.

What handles it

4 compounds tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
  • Arsenic
  • Haloacetic acids (HAA5)
  • Lead
  • Total trihalomethanes (TTHM)

What handles it

A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box. Wording varies a little: NSF writes “Lead Reduction,” WQA just “Lead.”

At the tap, or for the whole house?

These come with the water itself, so a whole-house system certified for the same claims treats every tap and shower. A filter at the tap treats drinking water for much less. How whole-house systems compare.

Filters with those claims on a certifier’s listing

None of the filters TapBuff has checked so far carry these claims. Search the certifier listings for the claim above.

Compare five-year costs

Hardness

Very hard, typically 342 mg/L (20 grains per gallon), across 4 sampling points, 2021 to 2024.

Hardness is calcium and magnesium. EPA sets no limit for it: it shows up as scale on fixtures and in water heaters, and as soap that won’t lather. USGS calls water above 60 mg/L moderately hard, above 120 hard and above 180 very hard.

Violations since 2016

No health-based violations on file with EPA since 2016.

What this report can’t tell you

  • Everything else. Uranium, nitrate, fluoride, chromium (total), arsenic, haloacetic acids (HAA5) and total trihalomethanes (TTHM) results here are California’s own from 2020 on, with EPA’s national file for 2012 to 2019. Spv Water Company’s own annual report, which it must send you every year, has the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; California’s results run from Jan. 8, 2020 to April 8, 2026.

Testing your own tap

Spv Water Company’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab California certifies.

The 3 labs California certifies closest to the area Spv Water Company serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

  • Pat-Chem Laboratories

    San Fernando, CA · about 18 miles

    Certified for bacteria, nitrate, lead and copper, metals, minerals and other inorganics, organic chemicals, disinfection byproducts, radioactivity

    (800) 400-5227

  • EMSL Analytical, Inc. (LA Testing)

    South Pasadena, CA · about 33 miles

    Certified for bacteria, asbestos

    (323) 254-9960

  • Positive Lab Service

    Los Angeles, CA · about 37 miles

    Certified for bacteria, nitrate, lead and copper, metals, minerals and other inorganics, organic chemicals, disinfection byproducts

    (213) 745-5312

All 145 certified labs for California

Sources

PWSID CA1907028. Rebuilt from EPA data on Oct. 18, 2026.