Skip to content
TapBuff

Long Beach Utilities Department

EPA’s and California’s records have results for 38 contaminants in its water; 9 were found.

Serves 466,772 people · Surface water bought from another system · Long Beach, CA · Hardness: varies by source

Serves
466,772 people
Connections
89,497
Water source
Surface water bought from another system
Based in
Long Beach, CA
County
Los Angeles
Owner
Local government
Hardness
Varies by source
The 15 ZIP codes it serves

90801, 90802, 90803, 90804, 90805, 90806, 90807, 90808, 90810, 90813, 90814, 90815, 90822, 90831, 90833

The short answer

None of the results here is above a limit in force today. Lithium is above EPA’s health benchmark. No health-based violations on file since 2016.

This is what the records show, not medical advice. Worried about a health effect? Talk to a doctor or your local health department.

Filters for arsenic, lead and uranium, if you want them lower⁠

What was found

Where these results come from, and when

PFAS and lithium: EPA UCMR 5, samples taken from April 20, 2023 to Jan. 18, 2024.

Lead and copper: EPA SDWIS monitoring periods ending 2004 to 2025.

Arsenic, total trihalomethanes (TTHM), haloacetic acids (HAA5), fluoride, nitrate, uranium and chromium (total): California’s own results, samples taken from Feb. 17, 2020 to June 29, 2026, with EPA’s 2012 to 2019 file for earlier years.

What the lines mean
Legal limit (MCL):
Enforceable. The most a utility may deliver.
Action level:
Triggers action. If more than 10% of homes sampled are above it, the utility must act.
90th percentile:
How a lead or copper result is held against its action level: nine in ten of the homes sampled were at or below it.
Health goal (MCLG):
Not enforceable. The level with no expected risk, with a margin of safety.
Health reference level:
A screening level from EPA’s work on whether to regulate a contaminant, where there is no legal limit or health goal; not enforceable.

PFAS: None of the six PFAS in EPA’s 2024 drinking water rule was found in this utility’s samples. None of the other 23 PFAS tested for was found either.

Above EPA’s health benchmark, 1 result

Lithium

Comes from the source

Above EPA’s health benchmark

54 ppb

Highest sample, Jan. 18, 2024; found in 6 of 8

The highest sample was 54 ppb, about 5.4 times EPA’s health reference level of 10 ppb. That is a screening level, not an enforceable limit.

What handles it

No filter certification covers lithium yet, and EPA’s 2023 fact sheet says boiling doesn’t remove it. Because it was found, your utility has to report its lithium results in its annual water quality report, where newer ones will appear.

How to read your utility’s report

Below EPA’s limits, 8 results

Arsenic, lead and uranium have a health goal of zero: the level with no known or expected risk. Any amount found is above it, but the goal isn’t a limit.

Legal limit (MCL):
Enforceable. The most a utility may deliver.
Action level:
Triggers action. If more than 10% of homes sampled are above it, the utility must act.
90th percentile:
How a lead or copper result is held against its action level: nine in ten of the homes sampled were at or below it.
Arsenic, Legal limit 10 ppb · health goal zero; highest yearly average 4.7 ppb

Highest yearly average, 2022 to 2026 · 2026 average: 2.0 ppb · Comes from the source

Averaged by year, the highest was 4.7 ppb, in 2023, below EPA’s legal limit of 10 ppb. Its health goal is zero, so any amount found is above it; the goal isn’t a limit. Its highest single sample was 17 ppb. In 2026, the latest year on file, its 54 samples averaged below the limit. EPA recorded no violation for arsenic at this utility since 2020.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 4.5 ppb, in 2013.

What handles it

  • NSF/ANSI 58 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
  • NSF/ANSI 53 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
About arsenic
Total trihalomethanes (TTHM), Legal limit 80 ppb; highest yearly average 33.5 ppb

Highest yearly average, 2020 to 2026 · Forms or is added in treatment

Averaged by year, the highest was 33.5 ppb, in 2026, below EPA’s legal limit of 80 ppb. Its highest single sample was 59 ppb. That was also the latest year on file.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 52.1 ppb, in 2012.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”
About total trihalomethanes (TTHM)
Haloacetic acids (HAA5), Legal limit 60 ppb; highest yearly average 13.2 ppb

Highest yearly average, 2020 to 2026 · 2026 average: 8.3 ppb · Forms or is added in treatment

Averaged by year, the highest was 13.2 ppb, in 2023, below EPA’s legal limit of 60 ppb. Its highest single sample was 20 ppb. In 2026, the latest year on file, its 24 samples averaged below the limit.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 19.9 ppb, in 2017.

What handles it

No certification claim covers this compound yet.

About haloacetic acids (HAA5)
Fluoride, Legal limit 4.0 ppm; highest yearly average 0.61 ppm

Highest yearly average, 2022 to 2026 · 2026 average: 0.6 ppm · Forms or is added in treatment

Averaged by year, the highest was 0.61 ppm, in 2024, below EPA’s legal limit of 4.0 ppm. Its highest single sample was 0.8 ppm. In 2026, the latest year on file, its 148 samples averaged below the limit.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 0.49 ppm, in 2019.

What handles it

About fluoride
Lead, Action level 15 ppb · health goal zero; 90th percentile 0.97 ppb

90th percentile, 2023 to 2025 · Comes from pipes, often your own

In the latest period, 9 in 10 homes sampled were at or below 0.97 ppb, below EPA’s action level of 15 ppb. The action level drops to 10 ppb on Nov. 1, 2027. EPA’s health goal for lead is zero.

What handles it

About lead
Nitrate, Legal limit 10 ppm; highest 0.32 ppm

Highest sample; found in 3 of 167 · 2026: not found · Comes from the source

The highest sample, in 2025, was 0.32 ppm, below EPA’s legal limit of 10 ppm. In 2026, the latest year on file, it wasn’t found in any of its 25 samples.

What handles it

  • NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
  • NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”
About nitrate
Uranium, Legal limit 30 ppb · health goal zero; highest yearly average 0.79 ppb

Highest yearly average, 2021 to 2026 · 2026: not found · Comes from the source

Averaged by year, the highest was 0.79 ppb, in 2022, below EPA’s legal limit of 30 ppb. Its health goal is zero, so any amount found is above it; the goal isn’t a limit. Its highest single sample was 4.0 ppb. In 2026, the latest year on file, it wasn’t found in any of its four samples.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 0.21 ppb, in 2016.

What handles it

About uranium
Chromium (total), Legal limit 100 ppb; highest yearly average 0.88 ppb

Highest yearly average, 2022 to 2026 · 2026 average: 0.43 ppb · Comes from the source

Averaged by year, the highest was 0.88 ppb, in 2025, below EPA’s legal limit of 100 ppb. Its highest single sample was 3.2 ppb. In 2026, the latest year on file, its 23 samples averaged below the limit.

What handles it

About chromium (total)
California utilities above EPA’s PFAS limits⁠
29 compounds tested and not foundIncluding all six PFAS in EPA’s 2024 rule. Below the reporting level in every sample. Not found is not the same as zero.
  • 11Cl-PF3OUdS
  • 4:2 FTS
  • 6:2 FTS
  • 8:2 FTS
  • 9Cl-PF3ONS
  • ADONA
  • HFPO-DA (GenX)
  • NEtFOSAA
  • NFDHA
  • NMeFOSAA
  • PFBA
  • PFBS
  • PFDA
  • PFDoA
  • PFEESA
  • PFHpA
  • PFHpS
  • PFHxA
  • PFHxS
  • PFMBA
  • PFMPA
  • PFNA
  • PFOA
  • PFOS
  • PFPeA
  • PFPeS
  • PFTA
  • PFTrDA
  • PFUnA

Violations since 2016

No health-based violations on file with EPA since 2016. There is 1 monitoring or reporting violation: a sample missed, late or not reported. EPA’s file runs to 2026 Q3, so a notice your utility sent since then may not be here yet.

Skip past the filters

What handles it

A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box.

  • NSF/ANSI 53

    Claims: Arsenic (Pentavalent)<=50 ppb Reduction, Lead Reduction

    For: Arsenic, Lead

    Other claims that cover it: Arsenic (III) (50 ppb influent level)

  • NSF/ANSI 58

    Claims: Arsenic (Pentavalent)<=50 ppb Reduction, Lead Reduction, Uranium

    For: Arsenic, Lead, Uranium

    Other claims that cover it: Arsenic (Pentavalent)<=300 ppb Reduction; Arsenic (V) (300 ppb influent level)

At the tap, or for the whole house?

These come with the water itself, so a whole-house system certified for the same claims treats every tap and shower. A filter at the tap treats drinking water for much less. How whole-house systems compare.

Filters with those claims on a certifier’s listing

Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money

2 more filters
Compare five-year costs

Every filter for these, those that cover all 3 first⁠

The best reverse osmosis systems, ranked⁠

The best water filters for lead, ranked⁠

Hardness

Soft to very hard depending on the source, 11 to 280 mg/L (0.6 to 16.4 grains per gallon), across 29 sampling points, 2019 to 2026.

Hardness is calcium and magnesium. EPA sets no limit for it: it shows up as scale on fixtures and in water heaters, and as soap that won’t lather. USGS calls water above 60 mg/L moderately hard, above 120 hard and above 180 very hard.

Disinfectant

Long Beach Utilities Department reported adding chloramine before water enters its pipes, at all 2 of its sampling points, in its 2023 to 2024 sampling for EPA. It also reported hydrogen peroxide and ozone.

What that means

Chloramine is chlorine combined with ammonia. It lasts longer in the pipes, and unlike chlorine, it doesn’t leave water that sits out. A filter’s chlorine claim doesn’t cover it: look for the separate chloramine claim under NSF/ANSI 42. No shower filter can carry one: NSF/ANSI 177, the shower filter standard, covers free chlorine only. Fish, turtles and frogs need it removed from their water. This utility buys its water from another system, so what it reported may leave out treatment done before the water reaches it. This is what the utility reported for that sampling. Its annual water quality report says what it uses now.

What this report can’t tell you

  • Everything else. Arsenic, total trihalomethanes (TTHM), haloacetic acids (HAA5), fluoride, nitrate, uranium and chromium (total) results here are California’s own from 2020 on, with EPA’s national file for 2012 to 2019. Long Beach Utilities Department’s own annual report, which it must send you every year, has the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 samples are from April 20, 2023 to Jan. 18, 2024; California’s results run from Feb. 17, 2020 to June 29, 2026.

Testing your own tap

Long Beach Utilities Department’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab California certifies.

What to test for at your tap

  • Lead and copper. Both come mostly from a building’s own service line, solder and faucets, so a utility’s numbers can’t tell you yours. Long Beach Utilities Department’s latest lead sampling in EPA’s records, 2023 to 2025, had a 90th percentile of 0.97 ppb: 9 in 10 of the homes it sampled were at or below that. The action level is 15 ppb, dropping to 10 ppb in November 2027, and EPA’s health goal for lead is zero. About lead.
  • What Long Beach Utilities Department’s results flag: lithium. It is in the water the utility sends out, so a test of your tap mostly confirms it. Include it if you want a number for your own home.
The 3 labs California certifies closest to the area Long Beach Utilities Department serves, or a kit by mail

The 3 labs California certifies closest to the area Long Beach Utilities Department serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

  • Long Beach Public Health Laboratory

    Long Beach, CA · about 1 mile

    Certified for bacteria

    (562) 570-4080

  • Alpha Analytical Laboratories, Inc. - Los Angeles

    Signal Hill, CA · about 1 mile

    Certified for bacteria, nitrate, minerals and other inorganics

    (424) 267-5032

  • Applied Microbiological Services (AMS)

    Long Beach, CA · about 3 miles

    Certified for bacteria

    (562) 495-9500

All 145 certified labs for California⁠

Or test by mail

Tap Score sells lab tests as kits you fill at your tap and mail back. The sample goes to Tap Score’s lab, not one near you, so check that California certifies it for the test you want.

  • Tap Score

    Return shipping included.

    Tap Score says each kit ships to “an accredited laboratory” but doesn’t name it, so TapBuff can’t check it against California’s list.

Prices from Tap Score’s own store on Oct. 22, 2026.

What to do now

Sources

PWSID CA1910065. Rebuilt from EPA data on Oct. 25, 2026.