San Fernando - City, Water Dept.
EPA’s and California’s records have results for 38 contaminants in its water; 7 were found.
Serves 23,364 people · Groundwater · San Fernando, CA · Hardness: very hard
- Serves
- 23,364 people
- Connections
- 5,421
- Water source
- Groundwater
- Based in
- San Fernando, CA
- County
- Los Angeles
- Owner
- Local government
- Hardness
- Very hard
The ZIP code it serves
The short answer
Nitrate averaged above its legal limit’s level in 2022, with no violation recorded. No health-based violations on file since 2016.
This is what the records show, not medical advice. Worried about a health effect? Talk to a doctor or your local health department.
What was found
Where these results come from, and when
PFAS and lithium: EPA UCMR 5, samples taken from Aug. 14, 2024 to Feb. 12, 2025.
Nitrate, total trihalomethanes (TTHM), fluoride, uranium, haloacetic acids (HAA5), chromium (total) and arsenic: California’s own results, samples taken from Jan. 2, 2020 to July 15, 2026, with EPA’s 2012 to 2019 file for earlier years.
What the lines mean
- Legal limit (MCL):
- Enforceable. The most a utility may deliver.
- Health goal (MCLG):
- Not enforceable. The level with no expected risk, with a margin of safety.
PFAS: None of the six PFAS in EPA’s 2024 drinking water rule was found in this utility’s samples. None of the other 23 PFAS tested for was found either.
Above the limit’s level, no violation recorded, 1 result
Nitrate
Comes from the source
What it means for you. Infants under six months are the ones at risk: EPA says they could become seriously ill. For an infant’s formula or food, use bottled water or ready-to-feed formula. EPA advises against water with more than 10 ppm, and CDC says boiling can’t make water with harmful chemicals safe.
12 ppm
Highest sample; found in 986 of 986
2026 average: 6.5 ppm
From 2020 to 2026, at least 25 samples were above EPA’s legal limit of 10 ppm, the highest 12 ppm in 2022. The next sample at the same point, within 30 days, kept the average above the limit for 19; six have no follow-up sample on file within 30 days. 10 ppm is also EPA’s health goal. In 2026, the latest year on file, its 130 samples averaged below the limit. EPA recorded no violation for nitrate at this utility since 2020.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest sample of 15 ppm, in 2016.
What handles it
- NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
- NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”
Below EPA’s limits, 6 results
Uranium and arsenic have a health goal of zero: the level with no known or expected risk. Any amount found is above it, but the goal isn’t a limit.
- Legal limit (MCL):
- Enforceable. The most a utility may deliver.
Total trihalomethanes (TTHM), Legal limit 80 ppb; highest yearly average 27.5 ppb
Highest yearly average, 2020 to 2026 · 2026 average: 3.8 ppb · Forms or is added in treatment
Averaged by year, the highest was 27.5 ppb, in 2023, below EPA’s legal limit of 80 ppb. Its highest single sample was 71 ppb. In 2026, the latest year on file, its 15 samples averaged below the limit.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest yearly average of 8.9 ppb, in 2016.
What handles it
- NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
- NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”
Fluoride, Legal limit 4.0 ppm; highest yearly average 0.33 ppm
Highest yearly average, 2020 to 2026 · Forms or is added in treatment
Averaged by year, the highest was 0.33 ppm, in 2026, below EPA’s legal limit of 4.0 ppm. Its highest single sample was 0.39 ppm. That was also the latest year on file.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest yearly average of 0.32 ppm, in 2014.
What handles it
- NSF/ANSI 58 look for “Fluoride Reduction”
- NSF/ANSI 53 look for “Fluoride”
Uranium, Legal limit 30 ppb · health goal zero; highest yearly average 2.1 ppb
Highest yearly average, 2020 to 2025 · Comes from the source
Averaged by year, the highest was 2.1 ppb, in 2025, below EPA’s legal limit of 30 ppb. Its health goal is zero, so any amount found is above it; the goal isn’t a limit. Its highest single sample was 3.0 ppb. That was also the latest year on file.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest yearly average of 1.5 ppb, in 2018.
What handles it
- NSF/ANSI 58 look for “Uranium”
Haloacetic acids (HAA5), Legal limit 60 ppb; highest yearly average 4.0 ppb
Highest yearly average, 2020 to 2026 · 2026: not found · Forms or is added in treatment
Averaged by year, the highest was 4.0 ppb, in 2023, below EPA’s legal limit of 60 ppb. Its highest single sample was 18 ppb. In 2026, the latest year on file, it wasn’t found in any of its 12 samples.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest yearly average of 0.67 ppb, in 2019.
What handles it
No certification claim covers this compound yet.
Chromium (total), Legal limit 100 ppb; highest yearly average 5.0 ppb
Highest yearly average, 2021 to 2025 · 2025 average: 3.7 ppb · Comes from the source
Averaged by year, the highest was 5.0 ppb, in 2023, below EPA’s legal limit of 100 ppb. Its highest single sample was 5.0 ppb. In 2025, the latest year on file, its nine samples averaged below the limit.
What handles it
- NSF/ANSI 58 look for “Chromium (Hexavalent) Reduction”
- NSF/ANSI 53 look for “Chromium Reduction”
Arsenic, Legal limit 10 ppb · health goal zero; highest yearly average 0.37 ppb
Highest yearly average, 2021 to 2025 · Comes from the source
Averaged by year, the highest was 0.37 ppb, in 2025, below EPA’s legal limit of 10 ppb. Its health goal is zero, so any amount found is above it; the goal isn’t a limit. Its highest single sample was 1.1 ppb. That was also the latest year on file.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest yearly average of 0.5 ppb, in 2018.
What handles it
- NSF/ANSI 58 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
- NSF/ANSI 53 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
31 compounds tested and not foundIncluding all six PFAS in EPA’s 2024 rule. Below the reporting level in every sample. Not found is not the same as zero.
From routine monitoring
- Lead
PFAS and lithium, from EPA’s UCMR 5 sampling
- 11Cl-PF3OUdS
- 4:2 FTS
- 6:2 FTS
- 8:2 FTS
- 9Cl-PF3ONS
- ADONA
- HFPO-DA (GenX)
- Lithium
- NEtFOSAA
- NFDHA
- NMeFOSAA
- PFBA
- PFBS
- PFDA
- PFDoA
- PFEESA
- PFHpA
- PFHpS
- PFHxA
- PFHxS
- PFMBA
- PFMPA
- PFNA
- PFOA
- PFOS
- PFPeA
- PFPeS
- PFTA
- PFTrDA
- PFUnA
What handles it
A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box.
- NSF/ANSI 53
Claims: Nitrate/Nitrite (30 ppm challenge), Arsenic (Pentavalent)<=50 ppb Reduction
For: Nitrate, Arsenic
Other claims that cover it: Arsenic (III) (50 ppb influent level)
- NSF/ANSI 58
Claims: Nitrate/Nitrite Reduction, Uranium, Arsenic (Pentavalent)<=50 ppb Reduction
For: Nitrate, Uranium, Arsenic
Other claims that cover it: Nitrate; Arsenic (Pentavalent)<=300 ppb Reduction; Arsenic (V) (300 ppb influent level)
At the tap, or for the whole house?
These come with the water itself, so a whole-house system certified for the same claims treats every tap and shower. A filter at the tap treats drinking water for much less. How whole-house systems compare.
Filters with those claims on a certifier’s listing
Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money
Countertop reverse osmosis
Five years: $1,344, household of 3, cartridges included
Certified for: Nitrate; also arsenic, found below its limits
Aquasana SmartFlow Reverse Osmosis (AQ-SFRO2)
Under-sink reverse osmosis
Five years: $2,917, household of 3, cartridges included
Certified for: Nitrate; also arsenic, found below its limits
Culligan 10-Cup Pitcher with ZeroWater Technology (ZEROP10)
Pitcher
Five years: $5,103, household of 3, cartridges included
Certified for: Nitrate
2 more filters
Under-sink reverse osmosis
Five years: $549, household of 3, cartridges included
WQA listing: NSF/ANSI 58, checked Oct. 9, 2026
Certified for arsenic only, found below its limits
Brondell Capella RC250 Reverse Osmosis System
Under-sink reverse osmosis
Five years: $1,950, household of 3, cartridges included
Certified for arsenic only, found below its limits
Hardness
Very hard, typically 268 mg/L (15.7 grains per gallon), across 4 sampling points, 2021 to 2025.
Hardness is calcium and magnesium. EPA sets no limit for it: it shows up as scale on fixtures and in water heaters, and as soap that won’t lather. USGS calls water above 60 mg/L moderately hard, above 120 hard and above 180 very hard.
Disinfectant
San Fernando - City, Water Dept. reported adding no disinfectant at all 4 of its sampling points, in its 2024 to 2025 sampling for EPA.
What that means
Most utilities add chlorine or chloramine. CDC says some that draw groundwater don’t need a disinfectant, because testing shows the water doesn’t carry enough germs to make people sick. This is what the utility reported for that sampling. Its annual water quality report says what it uses now.
Violations since 2016
No health-based violations on file with EPA since 2016. EPA’s file runs to 2026 Q3, so a notice your utility sent since then may not be here yet.
What this report can’t tell you
Everything else. Nitrate, total trihalomethanes (TTHM), fluoride, uranium, haloacetic acids (HAA5), chromium (total) and arsenic results here are California’s own from 2020 on, with EPA’s national file for 2012 to 2019. San Fernando - City, Water Dept.’s own annual report, which it must send you every year, has the contaminants this page does not show.
Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.
What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.
Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 samples are from Aug. 14, 2024 to Feb. 12, 2025; California’s results run from Jan. 2, 2020 to July 15, 2026.
Testing your own tap
What to test for at your tap
- Lead and copper. Both come mostly from a building’s own service line, solder and faucets, so a utility’s numbers can’t tell you yours. San Fernando - City, Water Dept.’s latest lead sampling in EPA’s records, 2021 to 2023, had a 90th percentile of 0 ppb across the homes it sampled. The action level is 15 ppb, dropping to 10 ppb in November 2027, and EPA’s health goal for lead is zero. About lead.
- What San Fernando - City, Water Dept.’s results flag: nitrate. It is in the water the utility sends out, so a test of your tap mostly confirms it. Include it if you want a number for your own home.
The 3 labs California certifies closest to the area San Fernando - City, Water Dept. serves, or a kit by mail
The 3 labs California certifies closest to the area San Fernando - City, Water Dept. serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.
Pat-Chem Laboratories
San Fernando, CA · about 1 mile
Certified for bacteria, nitrate, lead and copper, metals, minerals and other inorganics, organic chemicals, disinfection byproducts, radioactivity
EMSL Analytical, Inc. (LA Testing)
South Pasadena, CA · about 19 miles
Certified for bacteria, asbestos
Positive Lab Service
Los Angeles, CA · about 21 miles
Certified for bacteria, nitrate, lead and copper, metals, minerals and other inorganics, organic chemicals, disinfection byproducts
Or test by mail
Tap Score sells lab tests as kits you fill at your tap and mail back. The sample goes to Tap Score’s lab, not one near you, so check that California certifies it for the test you want.
Tap Score
- Lead and Copper Water Test, with a pH test strip: $55
- Essential City Water Test, 25 metals, 4 minerals, nitrate, fluoride, hardness and pH: $189
Return shipping included.
Tap Score says each kit ships to “an accredited laboratory” but doesn’t name it, so TapBuff can’t check it against California’s list.
Prices from Tap Score’s own store on Oct. 22, 2026.
What to do now
- Read up on nitrateWhat it does to health, where it comes from, and the certification claim that addresses it.About nitrate
- Get the utility’s own reportSan Fernando - City, Water Dept. must send you a water quality report every year. It covers contaminants this page does not show.How to read it
- Test your own tap for leadIts latest lead sampling found none at the 90th percentile, but your own service line, solder and fixtures decide the lead at your faucet.Lead in your water: what to do
Sources
- EPA UCMR 5 occurrence data, file of Oct. 15, 2026
- EPA SDWA bulk download (SDWIS federal data), 2026 Q3
- California State Water Resources Control Board, Division of Drinking Water, results from Jan. 1, 2020 to July 17, 2026, read Oct. 8, 2026
- EPA Six-Year Review 4 compliance monitoring data, 2012 to 2019, file of Feb. 5, 2024
- Disinfectant: EPA UCMR 5 occurrence data, additional data elements, file of Oct. 15, 2026
- Certified labs: California State Water Resources Control Board, ELAP accredited laboratories and their fields of accreditation, read Oct. 17, 2026; distances from the Census 2020 ZIP code tabulation area gazetteer
- Hardness: California State Water Resources Control Board, Division of Drinking Water, results from Feb. 3, 2021 to Dec. 31, 2025, read Oct. 10, 2026
- Limits and goals: each contaminant’s page, with its EPA source.
- How this page is built: methodology.
PWSID CA1910143. Rebuilt from EPA data on Oct. 25, 2026.