TapBuff
Menu

Cutler PUDwater quality report, rewritten

Serves
6,200
Connections
1,234
Water source
Groundwater
Based in
Cutler, CA
County
Tulare
Owner
Local government

ZIP codes served: 93615

PWSID CA54100012026 edition · EPA data

Read this first

Nothing in the federal data for this utility is above a health goal. That covers PFAS, lithium, lead and copper; it does not cover everything, so read what this report cannot tell you below.

5 health-based violations since 2016. Details are below.

What was found

Highlighted: above the health goal. Circled: above the legal limit in at least one sample. Every scale puts the legal line at its middle.

None of the contaminants in the federal data below were found at or above EPA’s reporting levels.

Tested and not found

Below EPA’s minimum reporting level in every sample taken from April 10, 2024 to Nov. 19, 2024. Not found means not measured above that level, which is not the same as zero.

  • 11Cl-PF3OUdS
  • 4:2 FTS
  • 6:2 FTS
  • 8:2 FTS
  • 9Cl-PF3ONS
  • ADONA
  • HFPO-DA (GenX)
  • Lead
  • Lithium
  • NEtFOSAA
  • NFDHA
  • NMeFOSAA
  • PFBA
  • PFBS
  • PFDA
  • PFDoA
  • PFEESA
  • PFHpA
  • PFHpS
  • PFHxA
  • PFHxS
  • PFMBA
  • PFMPA
  • PFNA
  • PFOA
  • PFOS
  • PFPeA
  • PFPeS
  • PFTA
  • PFTrDA
  • PFUnA

Violations since 2016

Contaminant or ruleTypePeriodMeasuredStatus
NitrateMaximum Contaminant Level Violation, Single SampleJan. 1, 2025 to March 31, 202511 MG/LArchived
LEAD AND COPPER RULE REVISIONSLSL InventoryOct. 17, 2024—Addressed
NitrateMaximum Contaminant Level Violation, Single SampleApril 1, 2024 to June 30, 202411 MG/LArchived
NitrateMaximum Contaminant Level Violation, Single SampleJan. 1, 2024 to March 31, 202411 MG/LArchived
NitrateMaximum Contaminant Level Violation, Single SampleJuly 1, 2023 to Sept. 30, 202310.5 MG/LArchived
Health-based violations only. Resolved and archived mean the utility returned to compliance or the state closed the record. 1 monitoring or reporting violation not shown.

What this report cannot tell you

  • Levels of everything else. Federal bulk data carries results for PFAS, lithium, lead and copper, and violations for the rest. Nitrate, arsenic, disinfection byproducts and other levels are in Cutler PUD’s own annual report, which it must send you every year.
  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.
  • Anything after the latest data. SDWIS data is from 2026 Q2; UCMR 5 samples are from April 10, 2024 to Nov. 19, 2024.