City of Corona
EPA’s and California’s records have results for 38 contaminants in its water; 13 were found.
Serves 169,380 people · Surface water bought from another system · Corona, CA · Hardness: hard
- Serves
- 169,380 people
- Connections
- 45,209
- Water source
- Surface water bought from another system
- Based in
- Corona, CA
- County
- Riverside
- Owner
- Local government
- Hardness
- Hard
The short answer
Nitrate averaged above its legal limit’s level in 2022, with no violation recorded. Lithium is above EPA’s health benchmark. No health-based violations on file since 2016.
This is what the records show, not medical advice. Worried about a health effect? Talk to a doctor or your local health department.
What was found
Where these results come from, and when
PFAS and lithium: EPA UCMR 5, samples taken from Sept. 20, 2023 to Sept. 11, 2024.
Lead and copper: EPA SDWIS monitoring periods ending 2005 to 2026.
Copper: EPA’s file records a utility’s copper only when it exceeds the action level. The last here was 1.8 ppm, for the period ending Dec. 31, 1992. None since is on file, so it is not counted as a current finding.
Nitrate, uranium, arsenic, total trihalomethanes (TTHM), haloacetic acids (HAA5), fluoride and chromium (total): California’s own results, samples taken from Jan. 2, 2020 to July 15, 2026, with EPA’s 2012 to 2019 file for earlier years.
What the lines mean
- Legal limit (MCL):
- Enforceable. The most a utility may deliver.
- Action level:
- Triggers action. If more than 10% of homes sampled are above it, the utility must act.
- 90th percentile:
- How a lead or copper result is held against its action level: nine in ten of the homes sampled were at or below it.
- EPA’s new limit:
- Final, but not enforced until April 26, 2029. From then on, the most a utility may deliver.
- Health goal (MCLG):
- Not enforceable. The level with no expected risk, with a margin of safety.
- Health reference level:
- A screening level from EPA’s work on whether to regulate a contaminant, where there is no legal limit or health goal; not enforceable.
PFAS: PFHxS was found, of the six PFAS in EPA’s 2024 drinking water rule; its result is below. Three other PFAS with no federal limit were found, the highest PFBA at 7.6 ppt: see them below.
About PFAS certifications
NSF’s PFAS claims are tested to below 20 ppt. EPA’s limit is 10 ppt, and EPA says no certification yet shows a filter reaching its levels.
In the meantime, EPA says reducing the PFAS in your water is still an effective way to limit your exposure, and a filter does that only while it is maintained as its maker says, cartridges replaced on schedule. Showering, bathing and washing dishes in the water are unlikely to significantly increase your risk, EPA says, since little PFAS gets in through the skin.
Above the limit’s level, no violation recorded, 1 result
Nitrate
Comes from the source
What it means for you. Infants under six months are the ones at risk: EPA says they could become seriously ill. For an infant’s formula or food, use bottled water or ready-to-feed formula. EPA advises against water with more than 10 ppm, and CDC says boiling can’t make water with harmful chemicals safe.
22 ppm
Highest sample; found in 6,586 of 6,935
2026 average: 5.1 ppm
From 2020 to 2022, at least 25 samples were above EPA’s legal limit of 10 ppm, the highest 22 ppm in 2022. The next sample at the same point, within 30 days, kept the average above the limit every time. 10 ppm is also EPA’s health goal. In 2026, the latest year on file, its 555 samples averaged below the limit. EPA recorded no violation for nitrate at this utility since 2020.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest sample of 58.8 ppm, in 2015.
What handles it
- NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
- NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”
Above EPA’s health benchmark, 1 result
Lithium
Comes from the source
55.1 ppb
Highest sample, Dec. 14, 2023; found in 24 of 54
The highest sample was 55.1 ppb, about 5.5 times EPA’s health reference level of 10 ppb. That is a screening level, not an enforceable limit.
What handles it
No filter certification covers lithium yet, and EPA’s 2023 fact sheet says boiling doesn’t remove it. Because it was found, your utility has to report its lithium results in its annual water quality report, where newer ones will appear.
How to read your utility’s reportBelow EPA’s limits, 8 results
Uranium, arsenic and lead have a health goal of zero: the level with no known or expected risk. Any amount found is above it, but the goal isn’t a limit.
- Legal limit (MCL):
- Enforceable. The most a utility may deliver.
- Action level:
- Triggers action. If more than 10% of homes sampled are above it, the utility must act.
- 90th percentile:
- How a lead or copper result is held against its action level: nine in ten of the homes sampled were at or below it.
- EPA’s new limit:
- Final, but not enforced until April 26, 2029. From then on, the most a utility may deliver.
Uranium, Legal limit 30 ppb · health goal zero; highest yearly average 19.1 ppb
Highest yearly average, 2020 to 2026 · 2026 average: 9.2 ppb · Comes from the source
Averaged by year, the highest was 19.1 ppb, in 2022, below EPA’s legal limit of 30 ppb. Its health goal is zero, so any amount found is above it; the goal isn’t a limit. Its highest single sample was 34.3 ppb. In 2026, the latest year on file, its three samples averaged below the limit. EPA recorded no violation for uranium at this utility since 2020.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest yearly average of 22.1 ppb, in 2019.
What handles it
- NSF/ANSI 58 look for “Uranium”
PFHxS, EPA’s 2029 limit 10 ppt; highest 3.3 ppt
Highest sample, Sept. 20, 2023; found in 1 of 54 · Comes from the source
The highest sample was 3.3 ppt, below EPA’s new limit of 10 ppt, which takes effect in 2029.
What handles it
- NSF/ANSI 53 look for “Total PFAS Reduction”
Arsenic, Legal limit 10 ppb · health goal zero; highest yearly average 2.7 ppb
Highest yearly average, 2020 to 2026 · 2026 average: 2.5 ppb · Comes from the source
Averaged by year, the highest was 2.7 ppb, in 2025, below EPA’s legal limit of 10 ppb. Its health goal is zero, so any amount found is above it; the goal isn’t a limit. Its highest single sample was 13 ppb. In 2026, the latest year on file, its 15 samples averaged below the limit. EPA recorded no violation for arsenic at this utility since 2020.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest yearly average of 2.1 ppb, in 2018.
What handles it
- NSF/ANSI 58 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
- NSF/ANSI 53 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
Total trihalomethanes (TTHM), Legal limit 80 ppb; highest yearly average 15.9 ppb
Highest yearly average, 2020 to 2026 · 2026 average: 11.1 ppb · Forms or is added in treatment
Averaged by year, the highest was 15.9 ppb, in 2025, below EPA’s legal limit of 80 ppb. Its highest single sample was 63 ppb. In 2026, the latest year on file, its 31 samples averaged below the limit.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest yearly average of 16.3 ppb, in 2012.
What handles it
- NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
- NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”
Lead, Action level 15 ppb · health goal zero; 90th percentile 1.8 ppb
90th percentile, 2024 to 2026 · Comes from pipes, often your own
In the latest period, 9 in 10 homes sampled were at or below 1.8 ppb, below EPA’s action level of 15 ppb. The action level drops to 10 ppb on Nov. 1, 2027. EPA’s health goal for lead is zero.
What handles it
- NSF/ANSI 53 look for “Lead Reduction”
- NSF/ANSI 58 look for “Lead Reduction”
Haloacetic acids (HAA5), Legal limit 60 ppb; highest yearly average 7.0 ppb
Highest yearly average, 2020 to 2026 · Forms or is added in treatment
Averaged by year, the highest was 7.0 ppb, in 2026, below EPA’s legal limit of 60 ppb. Its highest single sample was 12 ppb. That was also the latest year on file.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest yearly average of 8.3 ppb, in 2012.
What handles it
No certification claim covers this compound yet.
Fluoride, Legal limit 4.0 ppm; highest yearly average 0.29 ppm
Highest yearly average, 2020 to 2026 · 2026 average: 0.28 ppm · Forms or is added in treatment
Averaged by year, the highest was 0.29 ppm, in 2021, below EPA’s legal limit of 4.0 ppm. Its highest single sample was 2.3 ppm. In 2026, the latest year on file, its 102 samples averaged below the limit.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest yearly average of 0.48 ppm, in 2013.
What handles it
- NSF/ANSI 58 look for “Fluoride Reduction”
- NSF/ANSI 53 look for “Fluoride”
Chromium (total), Legal limit 100 ppb; highest yearly average 1.1 ppb
Highest yearly average, 2020 to 2026 · 2026 average: 0.42 ppb · Comes from the source
Averaged by year, the highest was 1.1 ppb, in 2025, below EPA’s legal limit of 100 ppb. Its highest single sample was 6.8 ppb. In 2026, the latest year on file, its 15 samples averaged below the limit.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest yearly average of 0.43 ppb, in 2013.
What handles it
- NSF/ANSI 58 look for “Chromium (Hexavalent) Reduction”
- NSF/ANSI 53 look for “Chromium Reduction”
EPA’s 2024 PFAS rule, compound by compoundAll six, found or not, and the Hazard Index, against the rule’s limits.
| PFAS | EPA’s limit | Result |
|---|---|---|
| PFOA | 4.0 ppt | Not foundNot found in any of 54 samples, below 4 ppt |
| PFOS | 4.0 ppt | Not foundNot found in any of 54 samples, below 4 ppt |
| PFHxS | 10 ppt | Below EPA’s limits3.3 ppt highest, found in 1 of 54 samples. Details |
| PFNA | 10 ppt | Not foundNot found in any of 54 samples, below 4 ppt |
| HFPO-DA (GenX) | 10 ppt | Not foundNot found in any of 54 samples, below 5 ppt |
| PFBS | Index only | Not foundNot found in any of 54 samples, below 3 ppt |
| Hazard IndexPFHxS, PFNA, HFPO-DA and PFBS together | 1 | Doesn’t applyDoesn’t apply: no sampling location found two or more of the four |
| Results from EPA’s UCMR 5 sampling. “Below” is the lab’s reporting level: a result under it reads as not found, which is not the same as zero. The limits are EPA’s 2024 rule, with compliance due from 2029; EPA has since proposed changes to some of them, explained on each compound’s page. PFBS has no limit of its own and counts only toward the Hazard Index, which adds up the four, each against EPA’s health-based level, from each sampling location’s average, as EPA’s UCMR 5 summary does. It counts only where two or more of the four were found, and is above the limit from 1.5. | ||
Also found, with no federal limit
EPA measured these PFAS to learn how often they occur. None has a legal limit or a health goal yet.
| Compound | Highest sample | Found in | Certification claim |
|---|---|---|---|
| PFBA | 7.6 ppt | 2 of 54 | None covers it |
| PFPeA | 6.1 ppt | 4 of 54 | None covers it |
| PFHxA | 3.8 ppt | 1 of 54 | None covers it |
25 compounds tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
- 11Cl-PF3OUdS
- 4:2 FTS
- 6:2 FTS
- 8:2 FTS
- 9Cl-PF3ONS
- ADONA
- HFPO-DA (GenX)
- NEtFOSAA
- NFDHA
- NMeFOSAA
- PFBS
- PFDA
- PFDoA
- PFEESA
- PFHpA
- PFHpS
- PFMBA
- PFMPA
- PFNA
- PFOA
- PFOS
- PFPeS
- PFTA
- PFTrDA
- PFUnA
What handles it
A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box.
- NSF/ANSI 53
Claims: Nitrate/Nitrite (30 ppm challenge), Arsenic (Pentavalent)<=50 ppb Reduction, Lead Reduction
For: Nitrate, Arsenic, Lead
Other claims that cover it: Arsenic (III) (50 ppb influent level)
- NSF/ANSI 58
Claims: Nitrate/Nitrite Reduction, Uranium, Arsenic (Pentavalent)<=50 ppb Reduction, Lead Reduction
For: Nitrate, Uranium, Arsenic, Lead
Other claims that cover it: Nitrate; Arsenic (Pentavalent)<=300 ppb Reduction; Arsenic (V) (300 ppb influent level)
At the tap, or for the whole house?
These come with the water itself, so a whole-house system certified for the same claims treats every tap and shower. A filter at the tap treats drinking water for much less. How whole-house systems compare.
Filters with those claims on a certifier’s listing
Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money
Countertop reverse osmosis
Five years: $1,344, household of 3, cartridges included
Certified for: Nitrate; also arsenic and lead, found below their limits
Aquasana SmartFlow Reverse Osmosis (AQ-SFRO2)
Under-sink reverse osmosis
Five years: $2,917, household of 3, cartridges included
Certified for: Nitrate; also arsenic and lead, found below their limits
Culligan 10-Cup Pitcher with ZeroWater Technology (ZEROP10)
Pitcher
Five years: $5,103, household of 3, cartridges included
Certified for: Nitrate; also lead, found below its limits
2 more filters
Express Water StreamLine Direct Connect System (USC001)
Under-sink carbon
Five years: $527, household of 3, cartridges included
Certified for lead only, found below its limits
Under-sink reverse osmosis
Five years: $549, household of 3, cartridges included
WQA listing: NSF/ANSI 58, checked Oct. 9, 2026
Certified for arsenic and lead only, found below their limits
Every filter certified for it
Hardness
Hard on average, 146 mg/L (8.5 grains per gallon), ranging from 7.2 to 290 mg/L, in its 2026 water quality report.
Hardness is calcium and magnesium. EPA sets no limit for it: it shows up as scale on fixtures and in water heaters, and as soap that won’t lather. USGS calls water above 60 mg/L moderately hard, above 120 hard and above 180 very hard.
Disinfectant
City of Corona reported chloramine at 12 of its 15 sampling points and chlorine without chloramine at 3, in its 2023 to 2024 sampling for EPA. Which one reaches your tap can depend on where you live.
What that means
Chloramine is chlorine combined with ammonia. It lasts longer in the pipes, and unlike chlorine, it doesn’t leave water that sits out. A filter’s chlorine claim doesn’t cover it: look for the separate chloramine claim under NSF/ANSI 42. No shower filter can carry one: NSF/ANSI 177, the shower filter standard, covers free chlorine only. Fish, turtles and frogs need it removed from their water. This utility buys its water from another system, so what it reported may leave out treatment done before the water reaches it. This is what the utility reported for that sampling. Its annual water quality report says what it uses now.
Violations since 2016
No health-based violations on file with EPA since 2016. There are 68 monitoring or reporting violations: a sample missed, late or not reported. EPA’s file runs to 2026 Q3, so a notice your utility sent since then may not be here yet.
What this report can’t tell you
Everything else. Nitrate, uranium, arsenic, total trihalomethanes (TTHM), haloacetic acids (HAA5), fluoride and chromium (total) results here are California’s own from 2020 on, with EPA’s national file for 2012 to 2019. City of Corona’s own annual report, which it must send you every year, has the contaminants this page does not show.
Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.
What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.
Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 samples are from Sept. 20, 2023 to Sept. 11, 2024; California’s results run from Jan. 2, 2020 to July 15, 2026.
Testing your own tap
What to test for at your tap
- Lead and copper. Both come mostly from a building’s own service line, solder and faucets, so a utility’s numbers can’t tell you yours. City of Corona’s latest lead sampling in EPA’s records, 2024 to 2026, had a 90th percentile of 1.8 ppb: 9 in 10 of the homes it sampled were at or below that. The action level is 15 ppb, dropping to 10 ppb in November 2027, and EPA’s health goal for lead is zero. About lead.
- What City of Corona’s results flag: nitrate and lithium. These are in the water the utility sends out, so a test of your tap mostly confirms them. Include them if you want a number for your own home.
The 3 labs California certifies closest to the area City of Corona serves, or a kit by mail
The 3 labs California certifies closest to the area City of Corona serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.
Western Analytical Laboratories, Inc.
Chino, CA · about 14 miles
Certified for bacteria, minerals and other inorganics
A & R Laboratories, Inc.
Ontario, CA · about 14 miles
Certified for bacteria
Babcock Laboratories, Inc.
Riverside, CA · about 16 miles
Certified for bacteria, nitrate, lead and copper, metals, minerals and other inorganics, organic chemicals, disinfection byproducts, PFAS, radioactivity
Or test by mail
Tap Score sells lab tests as kits you fill at your tap and mail back. The sample goes to Tap Score’s lab, not one near you, so check that California certifies it for the test you want.
Tap Score
- Lead and Copper Water Test, with a pH test strip: $55
- Essential City Water Test, 25 metals, 4 minerals, nitrate, fluoride, hardness and pH: $189
Return shipping included.
Tap Score says each kit ships to “an accredited laboratory” but doesn’t name it, so TapBuff can’t check it against California’s list.
Prices from Tap Score’s own store on Oct. 22, 2026.
What to do now
- Read up on these 2 resultsWhat each one does to health, where it comes from, and the certification claim that addresses it.Start with nitrate
- Get the utility’s own reportCity of Corona must send you a water quality report every year. It covers contaminants this page does not show.How to read it
- Test your own tap for leadYour service line, solder and fixtures decide the lead at your faucet, not the utility’s average.Lead in your water: what to do
Sources
- EPA UCMR 5 occurrence data, file of Oct. 15, 2026
- EPA SDWA bulk download (SDWIS federal data), 2026 Q3
- California State Water Resources Control Board, Division of Drinking Water, results from Jan. 1, 2020 to July 17, 2026, read Oct. 8, 2026
- EPA Six-Year Review 4 compliance monitoring data, 2012 to 2019, file of Feb. 5, 2024
- Disinfectant: EPA UCMR 5 occurrence data, additional data elements, file of Oct. 15, 2026
- Hardness: 2026 Consumer Confidence Report, read Oct. 10, 2026
- Certified labs: California State Water Resources Control Board, ELAP accredited laboratories and their fields of accreditation, read Oct. 17, 2026; distances from the Census 2020 ZIP code tabulation area gazetteer
- Limits and goals: each contaminant’s page, with its EPA source.
- How this page is built: methodology.
PWSID CA3310037. Rebuilt from EPA data on Oct. 25, 2026.