Skip to content
TapBuff

Vera Water & Power

EPA’s and Washington’s records have results for 37 contaminants in its water; 5 were found.

Serves 24,692 people · Groundwater · Spokane Valley, WA · Hardness: moderately hard

Serves
24,692 people
Connections
12,078
Water source
Groundwater
Based in
Spokane Valley, WA
County
Spokane
Owner
Local government
Hardness
Moderately hard
The 4 ZIP codes it serves

99016, 99023, 99037, 99216

The short answer

Lead is above the action level in the latest monitoring period, ending Dec. 31, 2025. No health-based violations on file since 2016.

This is what the records show, not medical advice. Worried about a health effect? Talk to a doctor or your local health department.

What handles it⁠

What was found

Where these results come from, and when

PFAS and lithium: EPA UCMR 5, samples taken from Aug. 24, 2023 to Feb. 29, 2024.

Lead and copper: EPA SDWIS monitoring periods ending 2003 to 2025.

Arsenic, nitrate, total trihalomethanes (TTHM), haloacetic acids (HAA5), chromium (total) and fluoride: Washington’s own results, samples taken from Aug. 17, 2020 to July 29, 2026, with EPA’s 2012 to 2019 file for earlier years.

What the lines mean
Legal limit (MCL):
Enforceable. The most a utility may deliver.
Action level:
Triggers action. If more than 10% of homes sampled are above it, the utility must act.
90th percentile:
How a lead or copper result is held against its action level: nine in ten of the homes sampled were at or below it.
Health goal (MCLG):
Not enforceable. The level with no expected risk, with a margin of safety.

PFAS: None of the six PFAS in EPA’s 2024 drinking water rule was found in this utility’s samples. None of the other 23 PFAS tested for was found either.

Above the legal limit, 1 result

Lead

Comes from pipes, often your own

Above the action level

What it means for you. EPA’s health goal for lead is zero: it can harm health even at low exposure. A utility over the action level must now tell its customers within 24 hours. Meanwhile, use only cold water for drinking, cooking and formula, run the tap after water has sat, and a filter certified for lead, at the tap you drink from, reduces it.

20.8 ppb

90th percentile, 2023 to 2025

In the latest period, 9 in 10 homes sampled were at or below 20.8 ppb, above EPA’s action level of 15 ppb. The action level drops to 10 ppb on Nov. 1, 2027, and this result is at or above that. EPA’s health goal for lead is zero.

What handles it

Below EPA’s limits, 4 results

Arsenic has a health goal of zero: the level with no known or expected risk. Any amount found is above it, but the goal isn’t a limit.

Legal limit (MCL):
Enforceable. The most a utility may deliver.
Arsenic, Legal limit 10 ppb · health goal zero; highest yearly average 3.8 ppb

Highest yearly average, 2020 to 2025 · 2025 average: 1.5 ppb · Comes from the source

Averaged by year, the highest was 3.8 ppb, in 2022, below EPA’s legal limit of 10 ppb. Its health goal is zero, so any amount found is above it; the goal isn’t a limit. Its highest single sample was 4.0 ppb. In 2025, the latest year on file, its two samples averaged below the limit.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 4.4 ppb, in 2019.

What handles it

  • NSF/ANSI 58 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
  • NSF/ANSI 53 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
About arsenic
Nitrate, Legal limit 10 ppm; highest 2.9 ppm

Highest sample; found in 54 of 62 · 2026 average: 0.92 ppm · Comes from the source

The highest sample, in 2021, was 2.9 ppm, below EPA’s legal limit of 10 ppm. In 2026, the latest year on file, its nine samples averaged below the limit.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest sample of 2.8 ppm, in 2015.

What handles it

  • NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
  • NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”
About nitrate
Total trihalomethanes (TTHM), Legal limit 80 ppb; highest yearly average 2.8 ppb

Highest yearly average, 2020 to 2025 · Forms or is added in treatment

Averaged by year, the highest was 2.8 ppb, in 2025, below EPA’s legal limit of 80 ppb. Its highest single sample was 5.7 ppb. That was also the latest year on file.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 4.3 ppb, in 2016.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”
About total trihalomethanes (TTHM)
Haloacetic acids (HAA5), Legal limit 60 ppb; highest yearly average 0.26 ppb

Highest yearly average, 2020 to 2025 · 2025: not found · Forms or is added in treatment

Averaged by year, the highest was 0.26 ppb, in 2024, below EPA’s legal limit of 60 ppb. Its highest single sample was 1.0 ppb. In 2025, the latest year on file, it wasn’t found in any of its four samples.

What handles it

No certification claim covers this compound yet.

About haloacetic acids (HAA5)
Washington utilities above EPA’s PFAS limits⁠
32 compounds tested and not foundIncluding all six PFAS in EPA’s 2024 rule. Below the reporting level in every sample. Not found is not the same as zero.

From routine monitoring

  • Chromium (total)
  • Fluoride

PFAS and lithium, from EPA’s UCMR 5 sampling

  • 11Cl-PF3OUdS
  • 4:2 FTS
  • 6:2 FTS
  • 8:2 FTS
  • 9Cl-PF3ONS
  • ADONA
  • HFPO-DA (GenX)
  • Lithium
  • NEtFOSAA
  • NFDHA
  • NMeFOSAA
  • PFBA
  • PFBS
  • PFDA
  • PFDoA
  • PFEESA
  • PFHpA
  • PFHpS
  • PFHxA
  • PFHxS
  • PFMBA
  • PFMPA
  • PFNA
  • PFOA
  • PFOS
  • PFPeA
  • PFPeS
  • PFTA
  • PFTrDA
  • PFUnA
Skip past the filters

What handles it

A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box.

  • NSF/ANSI 53

    Claims: Lead Reduction, Arsenic (Pentavalent)<=50 ppb Reduction

    For: Lead, Arsenic

    Other claims that cover it: Arsenic (III) (50 ppb influent level)

  • NSF/ANSI 58

    Claims: Lead Reduction, Arsenic (Pentavalent)<=50 ppb Reduction

    For: Lead, Arsenic

    Other claims that cover it: Arsenic (Pentavalent)<=300 ppb Reduction; Arsenic (V) (300 ppb influent level)

At the tap, or for the whole house?

Lead and copper usually come from pipes and fixtures inside or near your home. A whole-house system sits where water enters, so it cannot catch what your own plumbing adds after it. For those, the filter that counts is the one at the tap. How whole-house systems compare.

Filters with those claims on a certifier’s listing

Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money

2 more filters
Compare five-year costs

Every filter certified for it⁠

The best water filters for lead, ranked⁠

The best reverse osmosis systems, ranked⁠

Hardness

Moderately hard, typically 84 mg/L (4.9 grains per gallon), across 2 sampling points, 2020 to 2025.

Hardness is calcium and magnesium. EPA sets no limit for it: it shows up as scale on fixtures and in water heaters, and as soap that won’t lather. USGS calls water above 60 mg/L moderately hard, above 120 hard and above 180 very hard.

Disinfectant

Vera Water & Power reported another disinfectant but neither chlorine nor chloramine, in its 2023 to 2024 sampling for EPA.

What that means

Most utilities add chlorine or chloramine, CDC says. This is what the utility reported for that sampling. Its annual water quality report says what it uses now.

Violations since 2016

No health-based violations on file with EPA since 2016. There are 4 monitoring or reporting violations: a sample missed, late or not reported. EPA’s file runs to 2026 Q3, so a notice your utility sent since then may not be here yet.

What this report can’t tell you

  • Everything else. Arsenic, nitrate, total trihalomethanes (TTHM), haloacetic acids (HAA5), chromium (total) and fluoride results here are Washington’s own from 2020 on, with EPA’s national file for 2012 to 2019. Vera Water & Power’s own annual report, which it must send you every year, has the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 samples are from Aug. 24, 2023 to Feb. 29, 2024; Washington’s results run from Aug. 17, 2020 to July 29, 2026.

Testing your own tap

Vera Water & Power’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab Washington certifies.

What to test for at your tap

  • Lead and copper. Both come mostly from a building’s own service line, solder and faucets, so a utility’s numbers can’t tell you yours. Vera Water & Power’s latest lead sampling in EPA’s records, 2023 to 2025, had a 90th percentile of 20.8 ppb: 9 in 10 of the homes it sampled were at or below that. The action level is 15 ppb, dropping to 10 ppb in November 2027, and EPA’s health goal for lead is zero. About lead.
The 3 labs Washington certifies closest to the area Vera Water & Power serves, or a kit by mail

The 3 labs Washington certifies closest to the area Vera Water & Power serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

  • Eurofins Spokane

    Spokane Valley, WA · about 4 miles

    Certified for bacteria, nitrate, minerals and other inorganics

    (509) 924-9200

  • Tshimakain Creek Laboratories

    Spokane Valley, WA · about 7 miles

    Certified for bacteria, nitrate, minerals and other inorganics

    (509) 928-3577

  • Anatek Labs, Inc - Spokane

    Spokane, WA · about 10 miles

    Certified for bacteria, nitrate, lead and copper, metals, minerals and other inorganics, organic chemicals, disinfection byproducts, radioactivity

    (509) 838-3999

All 84 certified labs for Washington⁠

Or test by mail

Tap Score sells lab tests as kits you fill at your tap and mail back. The sample goes to Tap Score’s lab, not one near you, so check that Washington certifies it for the test you want.

  • Tap Score

    Return shipping included.

    Tap Score says each kit ships to “an accredited laboratory” but doesn’t name it, so TapBuff can’t check it against Washington’s list.

Prices from Tap Score’s own store on Oct. 22, 2026.

What to do now

Sources

PWSID WA5391450. Rebuilt from EPA data on Oct. 25, 2026.