Mountain View - Edgewood Water Co
EPA’s and Washington’s records have results for 35 contaminants in its water; 4 were found.
Serves 9,680 people · Groundwater · Edgewood, WA · Hardness: moderately hard
- Serves
- 9,680 people
- Connections
- 3,962
- Water source
- Groundwater
- Based in
- Edgewood, WA
- County
- Pierce
- Owner
- Private
- Hardness
- Moderately hard
The short answer
None of the results here is above a limit in force today. That covers PFAS and lithium; nitrate, arsenic and other regulated chemicals; and lead and copper, not everything. No health-based violations on file since 2016.
What was found
Where these results come from, and when
PFAS and lithium: EPA UCMR 5, samples taken from Jan. 23, 2024 to March 24, 2025.
Lead and copper: EPA SDWIS monitoring periods ending 2003 to 2024.
Copper: EPA’s file records a utility’s copper only when it exceeds the action level. The last here was 1.5 ppm, for the period ending Dec. 31, 1992. None since is on file, so it is not counted as a current finding.
Nitrate, arsenic, chromium (total) and fluoride: Washington’s own results, samples taken from June 25, 2020 to Sept. 14, 2026, with EPA’s 2012 to 2019 file for earlier years.
What the lines mean
- Legal limit (MCL):
- Enforceable. The most a utility may deliver.
- Action level:
- Triggers action. If more than 10% of homes sampled are above it, the utility must act.
- 90th percentile:
- How a lead or copper result is held against its action level: nine in ten of the homes sampled were at or below it.
- Health goal (MCLG):
- Not enforceable. The level with no expected risk, with a margin of safety.
- Health benchmark:
- A screening level EPA uses where there is no legal limit or health goal, not an enforceable limit.
PFAS: PFBS was found, of the six PFAS in EPA’s 2024 drinking water rule; its result is below. None of the other 23 PFAS tested for was found.
Below EPA’s limits, 4 results
Lead and arsenic have a health goal of zero: the level with no known or expected risk. Any amount found is above it, but the goal isn’t a limit.
- Legal limit (MCL):
- Enforceable. The most a utility may deliver.
- Action level:
- Triggers action. If more than 10% of homes sampled are above it, the utility must act.
- 90th percentile:
- How a lead or copper result is held against its action level: nine in ten of the homes sampled were at or below it.
- Health benchmark:
- A screening level EPA uses where there is no legal limit or health goal, not an enforceable limit.
Nitrate, Legal limit 10 ppm; highest 3.5 ppm
Highest sample; found in 41 of 45 · 2026 average: 1.9 ppm · Comes from the source
The highest sample, in 2023, was 3.5 ppm, below EPA’s legal limit of 10 ppm. In 2026, the latest year on file, its seven samples averaged below the limit.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest sample of 3.5 ppm, in 2017.
What handles it
- NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
- NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”
Lead, Action level 15 ppb · health goal zero; 90th percentile 4.0 ppb
90th percentile, 2022 to 2024 · Comes from pipes, often your own
In the latest period, 9 in 10 homes sampled were at or below 4.0 ppb, below EPA’s action level of 15 ppb. The action level drops to 10 ppb on Nov. 1, 2027. EPA’s health goal for lead is zero.
What handles it
- NSF/ANSI 53 look for “Lead Reduction”
- NSF/ANSI 58 look for “Lead Reduction”
Arsenic, Legal limit 10 ppb · health goal zero; highest yearly average 1.2 ppb
Highest yearly average, 2024 to 2025 · 2025, one sample: 1.1 ppb · Comes from the source
Averaged by year, the highest was 1.2 ppb, in 2024, below EPA’s legal limit of 10 ppb. Its health goal is zero, so any amount found is above it; the goal isn’t a limit. In 2025, the latest year on file, its one sample was below the limit.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest yearly average of 3.0 ppb, in 2013.
What handles it
- NSF/ANSI 58 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
- NSF/ANSI 53 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
PFBS, Health benchmark 2,000 ppt; highest 3.6 ppt
Highest sample, July 22, 2024; found in 2 of 12 · Comes from the source
The highest sample was 3.6 ppt, below EPA’s health benchmark of 2,000 ppt. PFBS has no legal limit or health goal of its own.
What handles it
- NSF/ANSI 53 look for “Total PFAS Reduction”
EPA’s 2024 PFAS rule, compound by compoundAll six, found or not, and the Hazard Index, against the rule’s limits.
| PFAS | EPA’s limit | Result |
|---|---|---|
| PFOA | 4.0 ppt | Not foundNot found in any of 12 samples, below 4 ppt |
| PFOS | 4.0 ppt | Not foundNot found in any of 12 samples, below 4 ppt |
| PFHxS | 10 ppt | Not foundNot found in any of 12 samples, below 3 ppt |
| PFNA | 10 ppt | Not foundNot found in any of 12 samples, below 4 ppt |
| HFPO-DA (GenX) | 10 ppt | Not foundNot found in any of 12 samples, below 5 ppt |
| PFBS | Index only | Below EPA’s limits3.6 ppt highest, found in 2 of 12 samples. Details |
| Hazard IndexPFHxS, PFNA, HFPO-DA and PFBS together | 1 | Doesn’t applyDoesn’t apply: no sampling location found two or more of the four |
| Results from EPA’s UCMR 5 sampling. “Below” is the lab’s reporting level: a result under it reads as not found, which is not the same as zero. The limits are EPA’s 2024 rule, with compliance due from 2029; EPA has since proposed changes to some of them, explained on each compound’s page. PFBS has no limit of its own and counts only toward the Hazard Index, which adds up the four, each against EPA’s health-based level, from each sampling location’s average, as EPA’s UCMR 5 summary does. It counts only where two or more of the four were found, and is above the limit from 1.5. | ||
31 compounds tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
From routine monitoring
- Chromium (total)
- Fluoride
PFAS and lithium, from EPA’s UCMR 5 sampling
- 11Cl-PF3OUdS
- 4:2 FTS
- 6:2 FTS
- 8:2 FTS
- 9Cl-PF3ONS
- ADONA
- HFPO-DA (GenX)
- Lithium
- NEtFOSAA
- NFDHA
- NMeFOSAA
- PFBA
- PFDA
- PFDoA
- PFEESA
- PFHpA
- PFHpS
- PFHxA
- PFHxS
- PFMBA
- PFMPA
- PFNA
- PFOA
- PFOS
- PFPeA
- PFPeS
- PFTA
- PFTrDA
- PFUnA
Violations since 2016
No health-based violations on file with EPA since 2016. EPA’s file runs to 2026 Q3, so a notice your utility sent since then may not be here yet.
What handles it
A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box.
- NSF/ANSI 53
Claims: Lead Reduction, Arsenic (Pentavalent)<=50 ppb Reduction
For: Lead, Arsenic
Other claims that cover it: Arsenic (III) (50 ppb influent level)
- NSF/ANSI 58
Claims: Lead Reduction, Arsenic (Pentavalent)<=50 ppb Reduction
For: Lead, Arsenic
Other claims that cover it: Arsenic (Pentavalent)<=300 ppb Reduction; Arsenic (V) (300 ppb influent level)
At the tap, or for the whole house?
These come with the water itself, so a whole-house system certified for the same claims treats every tap and shower. A filter at the tap treats drinking water for much less. How whole-house systems compare.
Filters with those claims on a certifier’s listing
Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money
Under-sink reverse osmosis
Five years: $549, household of 3, cartridges included
WQA listing: NSF/ANSI 58, checked Oct. 9, 2026
Certified for: Lead, Arsenic
Countertop reverse osmosis
Five years: $1,344, household of 3, cartridges included
Certified for: Lead, Arsenic
Brondell Capella RC250 Reverse Osmosis System
Under-sink reverse osmosis
Five years: $1,950, household of 3, cartridges included
Certified for: Lead, Arsenic
2 more filters
Aquasana SmartFlow Reverse Osmosis (AQ-SFRO2)
Under-sink reverse osmosis
Five years: $2,917, household of 3, cartridges included
Certified for: Lead, Arsenic
Express Water StreamLine Direct Connect System (USC001)
Under-sink carbon
Five years: $527, household of 3, cartridges included
Certified for: Lead
Every filter for these, those that cover both first
Hardness
Moderately hard, typically 102 mg/L (6 grains per gallon), across 2 sampling points, 2024 to 2025.
Hardness is calcium and magnesium. EPA sets no limit for it: it shows up as scale on fixtures and in water heaters, and as soap that won’t lather. USGS calls water above 60 mg/L moderately hard, above 120 hard and above 180 very hard.
Disinfectant
Mountain View - Edgewood Water Co reported adding no disinfectant at all 6 of its sampling points, in its 2024 to 2025 sampling for EPA.
What that means
Most utilities add chlorine or chloramine. CDC says some that draw groundwater don’t need a disinfectant, because testing shows the water doesn’t carry enough germs to make people sick. This is what the utility reported for that sampling. Its annual water quality report says what it uses now.
What this report can’t tell you
Everything else. Nitrate, arsenic, chromium (total) and fluoride results here are Washington’s own from 2020 on, with EPA’s national file for 2012 to 2019. Mountain View - Edgewood Water Co’s own annual report, which it must send you every year, has the contaminants this page does not show.
Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.
What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.
Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 samples are from Jan. 23, 2024 to March 24, 2025; Washington’s results run from June 25, 2020 to Sept. 14, 2026.
Testing your own tap
What to test for at your tap
- Lead and copper. Both come mostly from a building’s own service line, solder and faucets, so a utility’s numbers can’t tell you yours. Mountain View - Edgewood Water Co’s latest lead sampling in EPA’s records, 2022 to 2024, had a 90th percentile of 4.0 ppb: 9 in 10 of the homes it sampled were at or below that. The action level is 15 ppb, dropping to 10 ppb in November 2027, and EPA’s health goal for lead is zero. About lead.
The 3 labs Washington certifies closest to the area Mountain View - Edgewood Water Co serves, or a kit by mail
The 3 labs Washington certifies closest to the area Mountain View - Edgewood Water Co serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.
Water Management Laboratories, Inc.
Tacoma, WA · about 6 miles
Certified for bacteria, nitrate, lead and copper, metals, minerals and other inorganics, organic chemicals, disinfection byproducts, radioactivity
AmTest Laboratories
Renton, WA · about 19 miles
Certified for bacteria, nitrate, lead and copper, metals, minerals and other inorganics, disinfection byproducts
Analytical Resources, LLC
Tukwila, WA · about 20 miles
Certified for nitrate, lead and copper, metals, minerals and other inorganics
Or test by mail
Tap Score sells lab tests as kits you fill at your tap and mail back. The sample goes to Tap Score’s lab, not one near you, so check that Washington certifies it for the test you want.
Tap Score
- Lead and Copper Water Test, with a pH test strip: $55
- Essential City Water Test, 25 metals, 4 minerals, nitrate, fluoride, hardness and pH: $189
Return shipping included.
Tap Score says each kit ships to “an accredited laboratory” but doesn’t name it, so TapBuff can’t check it against Washington’s list.
Prices from Tap Score’s own store on Oct. 22, 2026.
What to do now
- Nothing here is above an EPA limit or health benchmarkIn EPA’s and Washington’s records for this utility. They don’t cover everything, which is why the next step matters.Every contaminant TapBuff tracks
- Get the utility’s own reportMountain View - Edgewood Water Co must send you a water quality report every year. It covers contaminants this page does not show.How to read it
- Test your own tap for leadYour service line, solder and fixtures decide the lead at your faucet, not the utility’s average.Lead in your water: what to do
Sources
- EPA UCMR 5 occurrence data, file of Oct. 15, 2026
- EPA SDWA bulk download (SDWIS federal data), 2026 Q3
- Washington State Department of Health, Office of Drinking Water, results from Jan. 1, 2020 to Sept. 29, 2026, read Oct. 8, 2026
- EPA Six-Year Review 4 compliance monitoring data, 2012 to 2019, file of Feb. 5, 2024
- Disinfectant: EPA UCMR 5 occurrence data, additional data elements, file of Oct. 15, 2026
- Certified labs: Washington State Department of Ecology, Lab Accreditation Program, environmental laboratories accredited for drinking water analyses, read Oct. 10, 2026; distances from the Census 2020 ZIP code tabulation area gazetteer
- Hardness: Washington State Department of Health, Office of Drinking Water, results from Sept. 9, 2024 to June 30, 2025, read Oct. 10, 2026
- Limits and goals: each contaminant’s page, with its EPA source.
- How this page is built: methodology.
PWSID WA5356820. Rebuilt from EPA data on Oct. 25, 2026.