Huston Twp Muni Auth
What EPA’s and Pennsylvania’s records show in this utility’s water: nitrate, arsenic and other regulated chemicals; lead and copper; and violations since 2016, with the certification that handles each result.
- Serves
- 960 people
- Connections
- 320
- Water source
- Surface water bought from another system
- Based in
- Penfield, PA
- County
- Clearfield
- Owner
- Local government
The ZIP code it serves
The short answer
1 result is above EPA’s legal limit. The worst: Lead, above the action level. No health-based violations on file since 2016.
What handles itWhat was found
Lead and copper: EPA SDWIS monitoring periods ending 1993 to 2016.
Total trihalomethanes (TTHM) and haloacetic acids (HAA5): Pennsylvania’s own results, samples taken from Jan. 15, 2020 to July 16, 2026, with EPA’s 2012 to 2019 file for earlier years.
Above the legal limit1
Lead
Comes from pipes, often your own
43.7ppb
90th percentile, 2016
In the latest period, 9 in 10 homes sampled were at or below 43.7 ppb, above EPA’s action level of 15 ppb. The action level drops to 10 ppb on Nov. 1, 2027, and this result is at or above that. EPA’s health goal for lead is zero.
What handles it
- NSF/ANSI 53 look for “Lead Reduction”
- NSF/ANSI 58 look for “Lead Reduction”
Below EPA’s limits2
Total trihalomethanes (TTHM)
Forms or is added in treatment
65.3ppb
Highest yearly average, 2020 to 2026
2026 average: 63.5 ppb
Averaged by year, the highest was 65.3 ppb, in 2025, below EPA’s legal limit of 80 ppb. Its highest single sample was 103 ppb. In 2026, the latest year on file, its three samples averaged 63.5 ppb. EPA recorded no violation for total trihalomethanes (TTHM) at this utility since 2020. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 53.9 ppb, in 2017.
What handles it
- NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
- NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”
Haloacetic acids (HAA5)
Forms or is added in treatment
16.2ppb
Highest yearly average, 2020 to 2026
Averaged by year, the highest was 16.2 ppb, in 2026, below EPA’s legal limit of 60 ppb. Its highest single sample was 44.5 ppb. That was also the latest year on file. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 150 ppb, in 2019.
What handles it
No certification claim covers this compound yet.
What handles it
A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box. Wording varies a little: NSF writes “Lead Reduction,” WQA just “Lead.”
- NSF/ANSI 53
Claim: Lead Reduction
For: Lead
- NSF/ANSI 58
Claim: Lead Reduction
For: Lead
At the tap, or for the whole house?
Lead and copper usually come from pipes and fixtures inside or near your home. A whole-house system sits where water enters, so it cannot catch what your own plumbing adds after it. For those, the filter that counts is the one at the tap. How whole-house systems compare.
Filters with those claims on a certifier’s listing
Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money
Brita Tahoe Pitcher with Elite Filter (OB60, OB06)
Pitcher
- WQA listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 401checked Oct. 13, 2026
- IAPMO listing:NSF/ANSI 53checked Oct. 13, 2026
Certified for: Lead
Brita Everyday Pitcher with Elite Filter (OB46, OB06)
Pitcher
- WQA listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 401checked Oct. 13, 2026
Certified for: Lead
PUR PLUS 11-Cup Pitcher (PPT111W)
Pitcher
- NSF listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 401checked Oct. 4, 2026
- WQA listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 401checked Oct. 4, 2026
- IAPMO listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 401checked Oct. 4, 2026
Certified for: Lead
ZeroWater 10 Cup Pitcher (ZP-010)
Pitcher
- IAPMO listing:NSF/ANSI 42NSF/ANSI 53checked Oct. 4, 2026
Certified for: Lead
Culligan 10-Cup Pitcher with ZeroWater Technology (ZEROP10)
Pitcher
- IAPMO listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 401checked Oct. 9, 2026
Certified for: Lead
Violations since 2016
No health-based violations on file with EPA since 2016. There are 34 monitoring or reporting violations: a sample missed, late or not reported.
What this report can’t tell you
Everything else. Total trihalomethanes (TTHM) and haloacetic acids (HAA5) results here are Pennsylvania’s own from 2020 on, with EPA’s national file for 2012 to 2019. Huston Twp Muni Auth’s own annual report, which it must send you every year, has the contaminants this page does not show.
Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.
What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.
Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; Pennsylvania’s results run from Jan. 15, 2020 to July 16, 2026.
Testing your own tap
The 3 labs Pennsylvania certifies closest to the area Huston Twp Muni Auth serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.
Pace Analytical Services, LLC - Dubois
Dubois, PA · about 8 miles
Certified for bacteria, nitrate
White Oak Laboratory LLC
Ridgway, PA · about 19 miles
Certified for bacteria, nitrate, minerals and other inorganics
G & C Coal Analysis Lab Inc
Summerville, PA · about 32 miles
Penn State Agricultural Analytical Services Laboratory: Drinking water test kits from many county Extension offices, mailed back to the lab overnight with payment. Packages cover bacteria and basic chemistry, with add-ons for nitrate, metals, lead, and mining or gas drilling concerns. The standard package of bacteria, pH and total dissolved solids is $60, or $70 with nitrate; bacteria alone is $40, nitrate $15 and lead $25. Drinking Water Testing, Penn State Agricultural Analytical Services Lab.
All 108 certified labs for PennsylvaniaSources
- EPA UCMR 5 occurrence data, file of Oct. 15, 2026
- EPA SDWA bulk download (SDWIS federal data), 2026 Q3
- Pennsylvania Department of Environmental Protection, Drinking Water Reporting System, results from Jan. 2, 2020 to Oct. 8, 2026, read Oct. 17, 2026
- EPA Six-Year Review 4 compliance monitoring data, 2012 to 2019, file of Feb. 5, 2024
- Certified labs: Pennsylvania DEP Laboratory Accreditation Program, accredited labs for drinking water, read Oct. 11, 2026; distances from the Census 2020 ZIP code tabulation area gazetteer
- Limits and goals: each contaminant’s page, with its EPA source.
- How this page is built: methodology.
PWSID PA6170024. Rebuilt from EPA data on Oct. 18, 2026.
What to do next
- Read up on LeadWhat each one does to health, where it comes from, and the certification claim that addresses it.About Lead
- Get the utility’s own reportHuston Twp Muni Auth must send you a water quality report every year. It covers contaminants this page does not show.How to read it
- Test your own tap for leadYour service line, solder and fixtures decide the lead at your faucet, not the utility’s average.Lead in your water: what to do
- Compare certified filtersWhat the filters certified for these results cost over five years, cartridges included.Compare five-year costs