Hatfield Water Dept
EPA’s and Massachusetts’s records have results for 37 contaminants in its water; 12 were found.
Serves 3,164 people · Surface water · Hatfield, MA · Hardness: varies by source
- Serves
- 3,164 people
- Connections
- 1,346
- Water source
- Surface water
- Based in
- Hatfield, MA
- County
- Hampshire
- Owner
- Local government
- Hardness
- Varies by source
The short answer
None of the results here is above a limit in force today. That covers PFAS and lithium; nitrate, arsenic and other regulated chemicals; and lead and copper, not everything. No health-based violations on file since 2016.
What was found
Where these results come from, and when
PFAS and lithium: EPA UCMR 5, samples taken from Feb. 5 to Nov. 4, 2024.
Lead and copper: EPA SDWIS monitoring periods ending 2019 to 2025.
Total trihalomethanes (TTHM), haloacetic acids (HAA5), nitrate, arsenic, fluoride and chromium (total): Massachusetts’s own results, samples taken from Feb. 20, 2020 to Aug. 19, 2026, with EPA’s 2012 to 2019 file for earlier years.
What the lines mean
- Legal limit (MCL):
- Enforceable. The most a utility may deliver.
- Action level:
- Triggers action. If more than 10% of homes sampled are above it, the utility must act.
- 90th percentile:
- How a lead or copper result is held against its action level: nine in ten of the homes sampled were at or below it.
- Health goal (MCLG):
- Not enforceable. The level with no expected risk, with a margin of safety.
- Health benchmark:
- A screening level EPA uses where there is no legal limit or health goal, not an enforceable limit.
- Health reference level:
- A screening level from EPA’s work on whether to regulate a contaminant, where there is no legal limit or health goal; not enforceable.
PFAS: PFBS was found, of the six PFAS in EPA’s 2024 drinking water rule; its result is below. Three other PFAS with no federal limit were found, the highest PFHxA at 60.8 ppt: see them below.
Below EPA’s limits, 9 results
Lead and arsenic have a health goal of zero: the level with no known or expected risk. Any amount found is above it, but the goal isn’t a limit.
- Legal limit (MCL):
- Enforceable. The most a utility may deliver.
- Action level:
- Triggers action. If more than 10% of homes sampled are above it, the utility must act.
- 90th percentile:
- How a lead or copper result is held against its action level: nine in ten of the homes sampled were at or below it.
- Health benchmark:
- A screening level EPA uses where there is no legal limit or health goal, not an enforceable limit.
- Health reference level:
- A screening level from EPA’s work on whether to regulate a contaminant, where there is no legal limit or health goal; not enforceable.
Lithium, Health reference level 10 ppbAt EPA’s benchmark, as EPA rounds; highest 11.4 ppb
Highest sample, Aug. 5, 2024; found in 2 of 8 · Comes from the source
The highest sample was 11.4 ppb. As EPA rounds results, that is at EPA’s health reference level of 10 ppb, not above it: EPA counts a result as above it from 15 ppb.
What handles it
No filter certification covers lithium yet, and EPA’s 2023 fact sheet says boiling doesn’t remove it. Because it was found, your utility has to report its lithium results in its annual water quality report, where newer ones will appear.
How to read your utility’s reportTotal trihalomethanes (TTHM), Legal limit 80 ppb; highest yearly average 41.5 ppb
Highest yearly average, 2020 to 2026 · 2026 average: 31.7 ppb · Forms or is added in treatment
Averaged by year, the highest was 41.5 ppb, in 2021, below EPA’s legal limit of 80 ppb. Its highest single sample was 62.1 ppb. In 2026, the latest year on file, its six samples averaged below the limit.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest yearly average of 43.7 ppb, in 2018.
What handles it
- NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
- NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”
Haloacetic acids (HAA5), Legal limit 60 ppb; highest yearly average 28.3 ppb
Highest yearly average, 2020 to 2026 · 2026 average: 20.6 ppb · Forms or is added in treatment
Averaged by year, the highest was 28.3 ppb, in 2025, below EPA’s legal limit of 60 ppb. Its highest single sample was 60.2 ppb. In 2026, the latest year on file, its six samples averaged below the limit. EPA recorded no violation for haloacetic acids (HAA5) at this utility since 2020.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest yearly average of 26.2 ppb, in 2018.
What handles it
No certification claim covers this compound yet.
Lead, Action level 15 ppb · health goal zero; 90th percentile 3.0 ppb
90th percentile, 2025 · Comes from pipes, often your own
In the latest period, 9 in 10 homes sampled were at or below 3.0 ppb, below EPA’s action level of 15 ppb. The action level drops to 10 ppb on Nov. 1, 2027. EPA’s health goal for lead is zero.
What handles it
- NSF/ANSI 53 look for “Lead Reduction”
- NSF/ANSI 58 look for “Lead Reduction”
Nitrate, Legal limit 10 ppm; highest 1.4 ppm
Highest sample; found in 19 of 21 · 2026 average: 0.76 ppm · Comes from the source
The highest sample, in 2022, was 1.4 ppm, below EPA’s legal limit of 10 ppm. In 2026, the latest year on file, its three samples averaged below the limit.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest sample of 1.7 ppm, in 2013.
What handles it
- NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
- NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”
Arsenic, Legal limit 10 ppb · health goal zero; highest yearly average 0.67 ppb
Highest yearly average, 2020 to 2026 · Comes from the source
Averaged by year, the highest was 0.67 ppb, in 2026, below EPA’s legal limit of 10 ppb. Its health goal is zero, so any amount found is above it; the goal isn’t a limit. Its highest single sample was 2.0 ppb. That was also the latest year on file.
What handles it
- NSF/ANSI 58 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
- NSF/ANSI 53 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
Fluoride, Legal limit 4.0 ppm; highest yearly average 0.047 ppm
Highest yearly average, 2020 to 2026 · Forms or is added in treatment
Averaged by year, the highest was 0.047 ppm, in 2026, below EPA’s legal limit of 4.0 ppm. Its highest single sample was 0.14 ppm. That was also the latest year on file.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest yearly average of 0.06 ppm, in 2012.
What handles it
- NSF/ANSI 58 look for “Fluoride Reduction”
- NSF/ANSI 53 look for “Fluoride”
PFBS, Health benchmark 2,000 ppt; highest 11.5 ppt
Highest sample, Nov. 4, 2024; found in 4 of 8 · Comes from the source
The highest sample was 11.5 ppt, below EPA’s health benchmark of 2,000 ppt. PFBS has no legal limit or health goal of its own.
What handles it
- NSF/ANSI 53 look for “Total PFAS Reduction”
Chromium (total), Legal limit 100 ppb; highest yearly average 0.37 ppb
Highest yearly average, 2020 to 2026 · Comes from the source
Averaged by year, the highest was 0.37 ppb, in 2026, below EPA’s legal limit of 100 ppb. Its highest single sample was 1.1 ppb. That was also the latest year on file.
What handles it
- NSF/ANSI 58 look for “Chromium (Hexavalent) Reduction”
- NSF/ANSI 53 look for “Chromium Reduction”
EPA’s 2024 PFAS rule, compound by compoundAll six, found or not, and the Hazard Index, against the rule’s limits.
| PFAS | EPA’s limit | Result |
|---|---|---|
| PFOA | 4.0 ppt | Not foundNot found in any of 8 samples, below 4 ppt |
| PFOS | 4.0 ppt | Not foundNot found in any of 8 samples, below 4 ppt |
| PFHxS | 10 ppt | Not foundNot found in any of 8 samples, below 3 ppt |
| PFNA | 10 ppt | Not foundNot found in any of 8 samples, below 4 ppt |
| HFPO-DA (GenX) | 10 ppt | Not foundNot found in any of 8 samples, below 5 ppt |
| PFBS | Index only | Below EPA’s limits11.5 ppt highest, found in 4 of 8 samples. Details |
| Hazard IndexPFHxS, PFNA, HFPO-DA and PFBS together | 1 | Doesn’t applyDoesn’t apply: no sampling location found two or more of the four |
| Results from EPA’s UCMR 5 sampling. “Below” is the lab’s reporting level: a result under it reads as not found, which is not the same as zero. The limits are EPA’s 2024 rule, with compliance due from 2029; EPA has since proposed changes to some of them, explained on each compound’s page. PFBS has no limit of its own and counts only toward the Hazard Index, which adds up the four, each against EPA’s health-based level, from each sampling location’s average, as EPA’s UCMR 5 summary does. It counts only where two or more of the four were found, and is above the limit from 1.5. | ||
Also found, with no federal limit
EPA measured these PFAS to learn how often they occur. None has a legal limit or a health goal yet.
| Compound | Highest sample | Found in | Certification claim |
|---|---|---|---|
| PFHxA | 60.8 ppt | 4 of 8 | None covers it |
| PFPeA | 58.1 ppt | 4 of 8 | None covers it |
| PFBA | 13.6 ppt | 3 of 8 | None covers it |
25 compounds tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
- 11Cl-PF3OUdS
- 4:2 FTS
- 6:2 FTS
- 8:2 FTS
- 9Cl-PF3ONS
- ADONA
- HFPO-DA (GenX)
- NEtFOSAA
- NFDHA
- NMeFOSAA
- PFDA
- PFDoA
- PFEESA
- PFHpA
- PFHpS
- PFHxS
- PFMBA
- PFMPA
- PFNA
- PFOA
- PFOS
- PFPeS
- PFTA
- PFTrDA
- PFUnA
Violations since 2016
No health-based violations on file with EPA since 2016. There is 1 monitoring or reporting violation: a sample missed, late or not reported. EPA’s file runs to 2026 Q3, so a notice your utility sent since then may not be here yet.
What handles it
A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box.
- NSF/ANSI 53
Claims: Lead Reduction, Arsenic (Pentavalent)<=50 ppb Reduction
For: Lead, Arsenic
Other claims that cover it: Arsenic (III) (50 ppb influent level)
- NSF/ANSI 58
Claims: Lead Reduction, Arsenic (Pentavalent)<=50 ppb Reduction
For: Lead, Arsenic
Other claims that cover it: Arsenic (Pentavalent)<=300 ppb Reduction; Arsenic (V) (300 ppb influent level)
At the tap, or for the whole house?
These come with the water itself, so a whole-house system certified for the same claims treats every tap and shower. A filter at the tap treats drinking water for much less. How whole-house systems compare.
Filters with those claims on a certifier’s listing
Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money
Under-sink reverse osmosis
Five years: $549, household of 3, cartridges included
WQA listing: NSF/ANSI 58, checked Oct. 9, 2026
Certified for: Lead, Arsenic
Countertop reverse osmosis
Five years: $1,344, household of 3, cartridges included
Certified for: Lead, Arsenic
Brondell Capella RC250 Reverse Osmosis System
Under-sink reverse osmosis
Five years: $1,950, household of 3, cartridges included
Certified for: Lead, Arsenic
2 more filters
Aquasana SmartFlow Reverse Osmosis (AQ-SFRO2)
Under-sink reverse osmosis
Five years: $2,917, household of 3, cartridges included
Certified for: Lead, Arsenic
Express Water StreamLine Direct Connect System (USC001)
Under-sink carbon
Five years: $527, household of 3, cartridges included
Certified for: Lead
Every filter for these, those that cover both first
Hardness
Soft to moderately hard depending on the source, 27 to 97 mg/L (1.6 to 5.7 grains per gallon), across 3 sampling points, 2015 to 2026.
Hardness is calcium and magnesium. EPA sets no limit for it: it shows up as scale on fixtures and in water heaters, and as soap that won’t lather. USGS calls water above 60 mg/L moderately hard, above 120 hard and above 180 very hard.
Disinfectant
Hatfield Water Dept reported chlorine, not chloramine, at 1 of its 3 sampling points, and no disinfectant at 2, in its 2024 sampling for EPA. It also reported chlorine dioxide.
What that means
Chlorine leaves water that sits out for a few days, CDC says. A filter certified for it carries a chlorine claim under NSF/ANSI 42; a shower filter, a free chlorine claim under NSF/ANSI 177. This is what the utility reported for that sampling. Its annual water quality report says what it uses now.
What this report can’t tell you
Everything else. Total trihalomethanes (TTHM), haloacetic acids (HAA5), nitrate, arsenic, fluoride and chromium (total) results here are Massachusetts’s own from 2020 on, with EPA’s national file for 2012 to 2019. Hatfield Water Dept’s own annual report, which it must send you every year, has the contaminants this page does not show.
Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.
What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.
Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 samples are from Feb. 5 to Nov. 4, 2024; Massachusetts’s results run from Feb. 20, 2020 to Aug. 19, 2026.
Testing your own tap
What to test for at your tap
- Lead and copper. Both come mostly from a building’s own service line, solder and faucets, so a utility’s numbers can’t tell you yours. Hatfield Water Dept’s latest lead sampling in EPA’s records, 2025, had a 90th percentile of 3.0 ppb: 9 in 10 of the homes it sampled were at or below that. The action level is 15 ppb, dropping to 10 ppb in November 2027, and EPA’s health goal for lead is zero. About lead.
The 3 labs Massachusetts certifies closest to the area Hatfield Water Dept serves, or a kit by mail
The 3 labs Massachusetts certifies closest to the area Hatfield Water Dept serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.
Howard Laboratories LLC
South Deerfield, MA · about 6 miles
Certified for bacteria
Quabbin Analytical Laboratory
Belchertown, MA · about 14 miles
Certified for bacteria
Vallid Labs Inc.
Agawam, MA · about 23 miles
Certified for bacteria
Or test by mail
Tap Score sells lab tests as kits you fill at your tap and mail back. The sample goes to Tap Score’s lab, not one near you, so check that Massachusetts certifies it for the test you want.
Tap Score
- Lead and Copper Water Test, with a pH test strip: $55
- Essential City Water Test, 25 metals, 4 minerals, nitrate, fluoride, hardness and pH: $189
Return shipping included.
Tap Score says each kit ships to “an accredited laboratory” but doesn’t name it, so TapBuff can’t check it against Massachusetts’s list.
Prices from Tap Score’s own store on Oct. 22, 2026.
What to do now
- Nothing here is above an EPA limit or health benchmarkIn EPA’s and Massachusetts’s records for this utility. They don’t cover everything, which is why the next step matters.Every contaminant TapBuff tracks
- Get the utility’s own reportHatfield Water Dept must send you a water quality report every year. It covers contaminants this page does not show.How to read it
- Test your own tap for leadYour service line, solder and fixtures decide the lead at your faucet, not the utility’s average.Lead in your water: what to do
Sources
- EPA UCMR 5 occurrence data, file of Oct. 15, 2026
- EPA SDWA bulk download (SDWIS federal data), 2026 Q3
- Massachusetts Department of Environmental Protection, Drinking Water Program, results from Jan. 2, 2020 to Oct. 5, 2026, read Oct. 8, 2026
- EPA Six-Year Review 4 compliance monitoring data, 2012 to 2019, file of Feb. 5, 2024
- Disinfectant: EPA UCMR 5 occurrence data, additional data elements, file of Oct. 15, 2026
- Certified labs: MassDEP Online Searchable Laboratory Certification Listing, potable water, read Oct. 16, 2026; distances from the Census 2020 ZIP code tabulation area gazetteer
- Hardness: Massachusetts Department of Environmental Protection, Drinking Water Program, results from April 14, 2015 to May 21, 2026, read Oct. 10, 2026
- Limits and goals: each contaminant’s page, with its EPA source.
- How this page is built: methodology.
PWSID MA1127000. Rebuilt from EPA data on Oct. 25, 2026.