Pinckneyville
EPA’s and Illinois’s records have results for 37 contaminants in its water; 5 were found.
Serves 5,804 people · Surface water · Pinckneyville, IL · Hardness: hard
- Serves
- 5,804 people
- Connections
- 1,786
- Water source
- Surface water
- Based in
- Pinckneyville, IL
- County
- Perry
- Owner
- Local government
- Hardness
- Hard
The ZIP code it serves
The short answer
EPA recorded a violation of the legal limit for total trihalomethanes (TTHM) here in 2025. In 2026, the latest year on file, it averaged 75.9 ppb, below the limit. 10 health-based violations since 2016, all resolved in EPA’s file.
This is what the records show, not medical advice. Worried about a health effect? Talk to a doctor or your local health department.
What handles itThe 10 violationsGot a notice? What it means
What was found
Where these results come from, and when
PFAS and lithium: EPA UCMR 5, samples taken from March 5 to Dec. 2, 2025.
Total trihalomethanes (TTHM), haloacetic acids (HAA5), nitrate, fluoride, arsenic and chromium (total): Illinois’s own results, samples taken from Jan. 15, 2020 to June 23, 2026, with EPA’s 2012 to 2019 file for earlier years.
What the lines mean
- Legal limit (MCL):
- Enforceable. The most a utility may deliver.
- Health goal (MCLG):
- Not enforceable. The level with no expected risk, with a margin of safety.
PFAS: None of the six PFAS in EPA’s 2024 drinking water rule was found in this utility’s samples. None of the other 23 PFAS tested for was found either.
A legal-limit violation on record, below the limit in the latest year, 1 result
Total trihalomethanes (TTHM)
Forms or is added in treatment
What it means for you. EPA’s concern is long-term exposure, years of drinking it, not an immediate risk to health. A violation like this calls for a notice to customers within 30 days. A filter certified for it, at the tap you drink from, reduces it.
75.9 ppb
Highest yearly average, 2020 to 2026
Averaged by year, the highest was 75.9 ppb, in 2026, below EPA’s legal limit of 80 ppb. Its highest single sample was 114 ppb. That was also the latest year on file. EPA recorded a violation for total trihalomethanes (TTHM) at this utility in 2025.
How it’s judged
EPA judges this limit at each sampling point, so a violation can be on record in a year whose average is below it.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest yearly average of 82.9 ppb, in 2018, and EPA recorded violations in 2018 and 2019.
What handles it
- NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
- NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”
Below EPA’s limits, 4 results
Arsenic has a health goal of zero: the level with no known or expected risk. Any amount found is above it, but the goal isn’t a limit.
- Legal limit (MCL):
- Enforceable. The most a utility may deliver.
Haloacetic acids (HAA5), Legal limit 60 ppb; highest yearly average 34.1 ppb
Highest yearly average, 2020 to 2026 · 2026 average: 32.6 ppb · Forms or is added in treatment
Averaged by year, the highest was 34.1 ppb, in 2024, below EPA’s legal limit of 60 ppb. Its highest single sample was 51.4 ppb. In 2026, the latest year on file, its six samples averaged below the limit.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest yearly average of 55.7 ppb, in 2015.
What handles it
No certification claim covers this compound yet.
Nitrate, Legal limit 10 ppm; highest 2.8 ppm
Highest sample; found in 7 of 7 · 2026, one sample: 0.29 ppm · Comes from the source
The highest sample, in 2021, was 2.8 ppm, below EPA’s legal limit of 10 ppm. In 2026, the latest year on file, its one sample was below the limit.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest sample of 0.19 ppm, in 2018.
What handles it
- NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
- NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”
Fluoride, Legal limit 4.0 ppm; highest yearly average 0.84 ppm
Highest yearly average, 2020 to 2026 · 2026, one sample: 0.75 ppm · Forms or is added in treatment
Averaged by year, the highest was 0.84 ppm, in 2021, below EPA’s legal limit of 4.0 ppm. In 2026, the latest year on file, its one sample was below the limit.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest yearly average of 1.0 ppm, in 2015.
What handles it
- NSF/ANSI 58 look for “Fluoride Reduction”
- NSF/ANSI 53 look for “Fluoride”
Arsenic, Legal limit 10 ppb · health goal zero; highest yearly average 0.75 ppb
Highest yearly average, 2020 to 2026 · Comes from the source
Averaged by year, the highest was 0.75 ppb, in 2026, below EPA’s legal limit of 10 ppb. Its health goal is zero, so any amount found is above it; the goal isn’t a limit. That was also the latest year on file.
What handles it
- NSF/ANSI 58 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
- NSF/ANSI 53 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
32 compounds tested and not foundIncluding all six PFAS in EPA’s 2024 rule. Below the reporting level in every sample. Not found is not the same as zero.
From routine monitoring
- Chromium (total)
- Lead
PFAS and lithium, from EPA’s UCMR 5 sampling
- 11Cl-PF3OUdS
- 4:2 FTS
- 6:2 FTS
- 8:2 FTS
- 9Cl-PF3ONS
- ADONA
- HFPO-DA (GenX)
- Lithium
- NEtFOSAA
- NFDHA
- NMeFOSAA
- PFBA
- PFBS
- PFDA
- PFDoA
- PFEESA
- PFHpA
- PFHpS
- PFHxA
- PFHxS
- PFMBA
- PFMPA
- PFNA
- PFOA
- PFOS
- PFPeA
- PFPeS
- PFTA
- PFTrDA
- PFUnA
What handles it
A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box.
- NSF/ANSI 53
Claims: Trihalomethanes (TTHM) Reduction, Arsenic (Pentavalent)<=50 ppb Reduction
For: Total trihalomethanes (TTHM), Arsenic
Other claims that cover it: VOC Reduction; Arsenic (III) (50 ppb influent level)
- NSF/ANSI 58
Claims: Trihalomethanes (TTHM) Reduction, Arsenic (Pentavalent)<=50 ppb Reduction
For: Total trihalomethanes (TTHM), Arsenic
Other claims that cover it: Arsenic (Pentavalent)<=300 ppb Reduction; Arsenic (V) (300 ppb influent level)
At the tap, or for the whole house?
These come with the water itself, so a whole-house system certified for the same claims treats every tap and shower. A filter at the tap treats drinking water for much less. How whole-house systems compare.
Filters with those claims on a certifier’s listing
Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money
Brondell Coral UC300 Under Sink Water Filtration System
Under-sink carbon
Five years: $900, household of 3, cartridges included
Certified for: Total trihalomethanes (TTHM)
A.O. Smith 2-Stage Under Sink Water Filter (AO-US-200)
Under-sink carbon
Five years: $980, household of 3, cartridges included
Certified for: Total trihalomethanes (TTHM)
Aquasana Claryum 2-Stage (AQ-6200)
Under-sink carbon
Five years: $990, household of 3, cartridges included
Certified for: Total trihalomethanes (TTHM)
2 more filters
Brita Elite Water Filter Faucet System (SAFF-100/FF-100)
Faucet mount
Five years: $1,004, household of 3, cartridges included
Certified for: Total trihalomethanes (TTHM)
Aquasana Clean Water Machine (AQ-CWM2)
Countertop
Five years: $1,061, household of 3, cartridges included
Certified for: Total trihalomethanes (TTHM)
Every filter certified for it
Hardness
Hard, 130 mg/L (7.6 grains per gallon), at its one sampling point, 2017 to 2026.
Hardness is calcium and magnesium. EPA sets no limit for it: it shows up as scale on fixtures and in water heaters, and as soap that won’t lather. USGS calls water above 60 mg/L moderately hard, above 120 hard and above 180 very hard.
Disinfectant
Pinckneyville reported adding chloramine before water enters its pipes, at its one sampling point, in its 2025 sampling for EPA.
What that means
Chloramine is chlorine combined with ammonia. It lasts longer in the pipes, and unlike chlorine, it doesn’t leave water that sits out. A filter’s chlorine claim doesn’t cover it: look for the separate chloramine claim under NSF/ANSI 42. No shower filter can carry one: NSF/ANSI 177, the shower filter standard, covers free chlorine only. Fish, turtles and frogs need it removed from their water. This is what the utility reported for that sampling. Its annual water quality report says what it uses now.
Violations since 2016
10 health-based violations since 2016, 5 for the Interim Enhanced Surface Water Treatment Rule and 5 for TTHM. The latest began June 1, 2025.
- Resolved:
- EPA’s file records a resolving action. The utility came back into compliance, the rule no longer applied, or no further action was needed.
- No fix on record:
- It records none. EPA’s own word for these is archived, addressed or unaddressed, shown beside each (EPA’s definitions, updated Oct. 9, 2026).
EPA’s file runs to 2026 Q3, so a notice your utility sent since then may not be here yet.
Got a notice about one? What it means and what to do| Contaminant or rule | What happened | Period, and what was measured | Status |
|---|---|---|---|
| Interim Enhanced Surface Water Treatment Rule | One cloudiness reading was above the maximum allowed.EPA: Single Turbidity Exceed (Enhanced SWTR) | June 1, 2025 to June 30, 2025 | Resolved |
| TTHM | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | Jan. 1, 2025 to March 31, 2025, 81 ppb | Resolved |
| Interim Enhanced Surface Water Treatment Rule | Too many readings in a month showed cloudiness above the filtration standard.EPA: Monthly Turbidity Exceed (Enhanced SWTR) | July 1, 2024 to July 31, 2024 | Resolved |
| June 1, 2024 to June 30, 2024 | Resolved | ||
| TTHM | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | Jan. 1, 2019 to March 31, 2019, 87 ppb | Resolved |
The other 5, back to 2016
| Contaminant or rule | What happened | Period, and what was measured | Status |
|---|---|---|---|
| TTHM | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | Oct. 1, 2018 to Dec. 31, 2018, 83 ppb | Resolved |
| Oct. 1, 2018 to Dec. 31, 2018, 86 ppb | Resolved | ||
| July 1, 2018 to Sept. 30, 2018, 82 ppb | Resolved | ||
| Interim Enhanced Surface Water Treatment Rule | Too many readings in a month showed cloudiness above the filtration standard.EPA: Monthly Turbidity Exceed (Enhanced SWTR) | June 1, 2016 to June 30, 2016 | Resolved |
| Interim Enhanced Surface Water Treatment Rule | One cloudiness reading was above the maximum allowed.EPA: Single Turbidity Exceed (Enhanced SWTR) | June 1, 2016 to June 30, 2016 | Resolved |
Health-based violations only. 13 monitoring or reporting violations not shown.
What this report can’t tell you
Everything else. Total trihalomethanes (TTHM), haloacetic acids (HAA5), nitrate, fluoride, arsenic and chromium (total) results here are Illinois’s own from 2020 on, with EPA’s national file for 2012 to 2019. Pinckneyville’s own annual report, which it must send you every year, has the contaminants this page does not show.
Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.
What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.
Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 samples are from March 5 to Dec. 2, 2025; Illinois’s results run from Jan. 15, 2020 to June 23, 2026.
Testing your own tap
What to test for at your tap
- Lead and copper. Both come mostly from a building’s own service line, solder and faucets, so a utility’s numbers can’t tell you yours. Pinckneyville’s latest lead sampling in EPA’s records, 2025, had a 90th percentile of 0 ppb across the homes it sampled. The action level is 15 ppb, dropping to 10 ppb in November 2027, and EPA’s health goal for lead is zero. About lead.
- What Pinckneyville’s results flag: total trihalomethanes (TTHM). It is in the water the utility sends out, so a test of your tap mostly confirms it. Include it if you want a number for your own home.
The 3 labs Illinois certifies closest to the area Pinckneyville serves, or a kit by mail
The 3 labs Illinois certifies closest to the area Pinckneyville serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.
Precision Water Lab
Centralia, IL · about 32 miles
Certified for bacteria
Teklab, Inc.
Collinsville, IL · about 51 miles
Certified for bacteria
BAR Laboratory / Brown & Roberts, Inc.
Harrisburg, IL · about 55 miles
Certified for bacteria
Or test by mail
Tap Score sells lab tests as kits you fill at your tap and mail back. The sample goes to Tap Score’s lab, not one near you, so check that Illinois certifies it for the test you want.
Tap Score
- Lead and Copper Water Test, with a pH test strip: $55
- Essential City Water Test, 25 metals, 4 minerals, nitrate, fluoride, hardness and pH: $189
Return shipping included.
Tap Score says each kit ships to “an accredited laboratory” but doesn’t name it, so TapBuff can’t check it against Illinois’s list.
Prices from Tap Score’s own store on Oct. 22, 2026.
What to do now
- Read up on total trihalomethanes (TTHM)What it does to health, where it comes from, and the certification claim that addresses it.About total trihalomethanes (TTHM)
- Get the utility’s own reportPinckneyville must send you a water quality report every year. It covers contaminants this page does not show.How to read it
- Test your own tap for leadIts latest lead sampling found none at the 90th percentile, but your own service line, solder and fixtures decide the lead at your faucet.Lead in your water: what to do
Sources
- EPA UCMR 5 occurrence data, file of Oct. 15, 2026
- EPA SDWA bulk download (SDWIS federal data), 2026 Q3
- Illinois Environmental Protection Agency, Bureau of Water, results from Jan. 2, 2020 to Oct. 13, 2026, read Oct. 17, 2026
- EPA Six-Year Review 4 compliance monitoring data, 2012 to 2019, file of Feb. 5, 2024
- Disinfectant: EPA UCMR 5 occurrence data, additional data elements, file of Oct. 15, 2026
- Certified labs: Illinois Department of Public Health, certified water microbiology laboratories, read Oct. 10, 2026; distances from the Census 2020 ZIP code tabulation area gazetteer
- Hardness: Illinois Environmental Protection Agency, Bureau of Water, results from Jan. 3, 2017 to Jan. 27, 2026, read Oct. 17, 2026
- Limits and goals: each contaminant’s page, with its EPA source.
- How this page is built: methodology.
PWSID IL1450150. Rebuilt from EPA data on Oct. 25, 2026.