North Tazewell PWD
EPA’s and Illinois’s records have results for 38 contaminants in its water; 8 were found.
Serves 7,625 people · Groundwater · East Peoria, IL · Hardness: very hard
- Serves
- 7,625 people
- Connections
- 3,050
- Water source
- Groundwater
- Based in
- East Peoria, IL
- County
- Tazewell
- Owner
- Local government
- Hardness
- Very hard
The short answer
EPA recorded a violation of the legal limit for total trihalomethanes (TTHM) here in 2020. In 2026, the latest year on file, it averaged 11.5 ppb, below the limit. EPA recorded a violation of the legal limit for haloacetic acids (HAA5) here in 2020. In 2026, the latest year on file, it averaged 7.1 ppb, below the limit. Copper is above the action level in the latest monitoring period, ending June 30, 2026. Arsenic averaged above its legal limit’s level in 2021, with no violation recorded. 13 health-based violations since 2016, all resolved in EPA’s file.
This is what the records show, not medical advice. Worried about a health effect? Talk to a doctor or your local health department.
What handles itThe 13 violationsGot a notice? What it means
What was found
Where these results come from, and when
PFAS and lithium: EPA UCMR 5, samples taken from June 3 to Dec. 3, 2025.
Lead and copper: EPA SDWIS monitoring periods ending 1992 to 2026.
Total trihalomethanes (TTHM), haloacetic acids (HAA5), arsenic, fluoride, nitrate and chromium (total): Illinois’s own results, samples taken from March 24, 2020 to Sept. 14, 2026, with EPA’s 2012 to 2019 file for earlier years.
What the lines mean
- Legal limit (MCL):
- Enforceable. The most a utility may deliver.
- Action level:
- Triggers action. If more than 10% of homes sampled are above it, the utility must act.
- 90th percentile:
- How a lead or copper result is held against its action level: nine in ten of the homes sampled were at or below it.
- Health goal (MCLG):
- Not enforceable. The level with no expected risk, with a margin of safety.
- Health reference level:
- A screening level from EPA’s work on whether to regulate a contaminant, where there is no legal limit or health goal; not enforceable.
PFAS: None of the six PFAS in EPA’s 2024 drinking water rule was found in this utility’s samples. None of the other 23 PFAS tested for was found either.
Above the legal limit, 1 result
Copper
Comes from pipes, often your own
What it means for you. EPA’s concern is stomach and intestinal distress from short-term exposure, and liver or kidney damage over years. A filter certified for it, at the tap you drink from, reduces it.
1.4 ppm
90th percentile, 2026
In the latest period, 9 in 10 homes sampled were at or below 1.4 ppm, above EPA’s action level of 1.3 ppm.
What handles it
- NSF/ANSI 53 look for “Copper Reduction”
- NSF/ANSI 58 look for “Copper Reduction”
A legal-limit violation on record, below the limit in the latest year, 2 results
Total trihalomethanes (TTHM)
Forms or is added in treatment
What it means for you. EPA’s concern is long-term exposure, years of drinking it, not an immediate risk to health. A violation like this calls for a notice to customers within 30 days. A filter certified for it, at the tap you drink from, reduces it.
76.6 ppb
Highest yearly average, 2020 to 2026
2026 average: 11.5 ppb
Averaged by year, the highest was 76.6 ppb, in 2020, below EPA’s legal limit of 80 ppb. Its highest single sample was 113 ppb. In 2026, the latest year on file, its two samples averaged below the limit. EPA recorded a violation for total trihalomethanes (TTHM) at this utility in 2020.
How it’s judged
EPA judges this limit at each sampling point, so a violation can be on record in a year whose average is below it.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest yearly average of 103 ppb, in 2015, and EPA recorded a violation in 2016.
What handles it
- NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
- NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”
Haloacetic acids (HAA5)
Forms or is added in treatment
What it means for you. EPA’s concern is long-term exposure, years of drinking it, not an immediate risk to health. A violation like this calls for a notice to customers within 30 days.
46.4 ppb
Highest yearly average, 2020 to 2026
2026 average: 7.1 ppb
Averaged by year, the highest was 46.4 ppb, in 2020, below EPA’s legal limit of 60 ppb. Its highest single sample was 79.7 ppb. In 2026, the latest year on file, its two samples averaged below the limit. EPA recorded a violation for haloacetic acids (HAA5) at this utility in 2020.
How it’s judged
EPA judges this limit at each sampling point, so a violation can be on record in a year whose average is below it.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest yearly average of 59.8 ppb, in 2015, and EPA recorded violations in 2016 and 2019.
What handles it
No certification claim covers this compound yet.
Above the limit’s level, no violation recorded, 1 result
Arsenic
Comes from the source
What it means for you. EPA’s concern is long-term exposure, years of drinking it, not an immediate risk to health. A filter certified for it, at the tap you drink from, reduces it.
15.9 ppb
Highest yearly average, 2021 to 2026
2026 average: 12.3 ppb
Averaged by year, the highest was 15.9 ppb, in 2021, above EPA’s legal limit of 10 ppb. Its highest single sample was 29 ppb. In 2026, the latest year on file, its nine samples averaged above the limit. EPA recorded no violation for arsenic at this utility since 2020.
How it’s judged
EPA judges this limit on running averages at each sampling point. Results like these with no violation often include water sampled before treatment or blending; the utility’s annual report says what reaches the tap.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest yearly average of 2.5 ppb, in 2012.
What handles it
- NSF/ANSI 58 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
- NSF/ANSI 53 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
Below EPA’s limits, 4 results
Lead has a health goal of zero: the level with no known or expected risk. Any amount found is above it, but the goal isn’t a limit.
- Legal limit (MCL):
- Enforceable. The most a utility may deliver.
- Action level:
- Triggers action. If more than 10% of homes sampled are above it, the utility must act.
- 90th percentile:
- How a lead or copper result is held against its action level: nine in ten of the homes sampled were at or below it.
- Health reference level:
- A screening level from EPA’s work on whether to regulate a contaminant, where there is no legal limit or health goal; not enforceable.
Lithium, Health reference level 10 ppb; highest 9.4 ppb
Highest sample, Dec. 3, 2025; found in 1 of 2 · Comes from the source
The highest sample was 9.4 ppb, below EPA’s health reference level of 10 ppb. Lithium has no legal limit or health goal of its own.
What handles it
No filter certification covers lithium yet, and EPA’s 2023 fact sheet says boiling doesn’t remove it. Because it was found, your utility has to report its lithium results in its annual water quality report, where newer ones will appear.
How to read your utility’s reportLead, Action level 15 ppb · health goal zero; 90th percentile 5.1 ppb
90th percentile, 2026 · Comes from pipes, often your own
In the latest period, 9 in 10 homes sampled were at or below 5.1 ppb, below EPA’s action level of 15 ppb. The action level drops to 10 ppb on Nov. 1, 2027. EPA’s health goal for lead is zero.
What handles it
- NSF/ANSI 53 look for “Lead Reduction”
- NSF/ANSI 58 look for “Lead Reduction”
Fluoride, Legal limit 4.0 ppm; highest yearly average 0.8 ppm
Highest yearly average, 2021 to 2024 · 2024, one sample: 0.3 ppm · Forms or is added in treatment
Averaged by year, the highest was 0.8 ppm, in 2021, below EPA’s legal limit of 4.0 ppm. In 2024, the latest year on file, its one sample was below the limit.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest yearly average of 1.0 ppm, in 2015.
What handles it
- NSF/ANSI 58 look for “Fluoride Reduction”
- NSF/ANSI 53 look for “Fluoride”
Nitrate, Legal limit 10 ppm; highest 1.0 ppm
Highest sample; found in 7 of 7 · 2026, one sample: 0.62 ppm · Comes from the source
The highest sample, in 2025, was 1.0 ppm, below EPA’s legal limit of 10 ppm. In 2026, the latest year on file, its one sample was below the limit.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest sample of 0.77 ppm, in 2018.
What handles it
- NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
- NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”
30 compounds tested and not foundIncluding all six PFAS in EPA’s 2024 rule. Below the reporting level in every sample. Not found is not the same as zero.
From routine monitoring
- Chromium (total)
PFAS and lithium, from EPA’s UCMR 5 sampling
- 11Cl-PF3OUdS
- 4:2 FTS
- 6:2 FTS
- 8:2 FTS
- 9Cl-PF3ONS
- ADONA
- HFPO-DA (GenX)
- NEtFOSAA
- NFDHA
- NMeFOSAA
- PFBA
- PFBS
- PFDA
- PFDoA
- PFEESA
- PFHpA
- PFHpS
- PFHxA
- PFHxS
- PFMBA
- PFMPA
- PFNA
- PFOA
- PFOS
- PFPeA
- PFPeS
- PFTA
- PFTrDA
- PFUnA
What handles it
A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box.
- NSF/ANSI 53
Claims: Copper Reduction, Trihalomethanes (TTHM) Reduction, Arsenic (Pentavalent)<=50 ppb Reduction, Lead Reduction
For: Copper, Total trihalomethanes (TTHM), Arsenic, Lead
Other claims that cover it: VOC Reduction; Arsenic (III) (50 ppb influent level)
- NSF/ANSI 58
Claims: Copper Reduction, Trihalomethanes (TTHM) Reduction, Arsenic (Pentavalent)<=50 ppb Reduction, Lead Reduction
For: Copper, Total trihalomethanes (TTHM), Arsenic, Lead
Other claims that cover it: Arsenic (Pentavalent)<=300 ppb Reduction; Arsenic (V) (300 ppb influent level)
At the tap, or for the whole house?
Lead and copper usually come from pipes and fixtures inside or near your home. A whole-house system sits where water enters, so it cannot catch what your own plumbing adds after it. For those, the filter that counts is the one at the tap. How whole-house systems compare.
Filters with those claims on a certifier’s listing
Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money
Countertop reverse osmosis
Five years: $1,344, household of 3, cartridges included
Certified for: Copper, Total trihalomethanes (TTHM), Arsenic; also lead, found below its limits
Brondell Capella RC250 Reverse Osmosis System
Under-sink reverse osmosis
Five years: $1,950, household of 3, cartridges included
Certified for: Copper, Total trihalomethanes (TTHM), Arsenic; also lead, found below its limits
Aquasana SmartFlow Reverse Osmosis (AQ-SFRO2)
Under-sink reverse osmosis
Five years: $2,917, household of 3, cartridges included
Certified for: Copper, Total trihalomethanes (TTHM), Arsenic; also lead, found below its limits
2 more filters
Under-sink reverse osmosis
Five years: $549, household of 3, cartridges included
WQA listing: NSF/ANSI 58, checked Oct. 9, 2026
Certified for: Copper, Arsenic; also lead, found below its limits
Brondell Coral UC300 Under Sink Water Filtration System
Under-sink carbon
Five years: $900, household of 3, cartridges included
Certified for: Total trihalomethanes (TTHM); also lead, found below its limits
Every filter for these, those that cover all 3 first
The best water filters for TTHM, ranked
Hardness
Very hard, 360 mg/L (21.1 grains per gallon), at its one sampling point, 2018 to 2024.
Hardness is calcium and magnesium. EPA sets no limit for it: it shows up as scale on fixtures and in water heaters, and as soap that won’t lather. USGS calls water above 60 mg/L moderately hard, above 120 hard and above 180 very hard.
Disinfectant
North Tazewell PWD reported disinfecting with chlorine, not chloramine, at its one sampling point, in its 2025 sampling for EPA.
What that means
Chlorine leaves water that sits out for a few days, CDC says. A filter certified for it carries a chlorine claim under NSF/ANSI 42; a shower filter, a free chlorine claim under NSF/ANSI 177. This is what the utility reported for that sampling. Its annual water quality report says what it uses now.
Violations since 2016
13 health-based violations since 2016, 7 for total Haloacetic Acids (HAA5), 5 for TTHM and 1 for the Lead and Copper Rule. The latest began July 1, 2022.
- Resolved:
- EPA’s file records a resolving action. The utility came back into compliance, the rule no longer applied, or no further action was needed.
- No fix on record:
- It records none. EPA’s own word for these is archived, addressed or unaddressed, shown beside each (EPA’s definitions, updated Oct. 9, 2026).
EPA’s file runs to 2026 Q3, so a notice your utility sent since then may not be here yet.
Got a notice about one? What it means and what to do| Contaminant or rule | What happened | Period, and what was measured | Status |
|---|---|---|---|
| Lead and Copper Rule | A required study or plan for corrosion control was not done on time.EPA: OCCT/SOWT Study/Recommendation | July 1, 2022 | Resolved |
| TTHM | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | Oct. 1, 2020 to Dec. 31, 2020, 87 ppb | Resolved |
| Total Haloacetic Acids (HAA5) | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | July 1, 2020 to Sept. 30, 2020, 71 ppb | Resolved |
| TTHM | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | July 1, 2020 to Sept. 30, 2020, 99 ppb | Resolved |
| Total Haloacetic Acids (HAA5) | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | April 1, 2020 to June 30, 2020, 67 ppb | Resolved |
The other 8, back to 2016
| Contaminant or rule | What happened | Period, and what was measured | Status |
|---|---|---|---|
| Total Haloacetic Acids (HAA5) | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | Jan. 1, 2020 to March 31, 2020, 65 ppb | Resolved |
| Oct. 1, 2019 to Dec. 31, 2019, 61 ppb | Resolved | ||
| July 1, 2016 to Sept. 30, 2016, 68 ppb | Resolved | ||
| TTHM | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | July 1, 2016 to Sept. 30, 2016, 97 ppb | Resolved |
| April 1, 2016 to June 30, 2016, 109 ppb | Resolved | ||
| Total Haloacetic Acids (HAA5) | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | April 1, 2016 to June 30, 2016, 72 ppb | Resolved |
| Jan. 1, 2016 to March 31, 2016, 68 ppb | Resolved | ||
| TTHM | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | Jan. 1, 2016 to March 31, 2016, 98 ppb | Resolved |
Health-based violations only. 3 monitoring or reporting violations not shown.
What this report can’t tell you
Everything else. Total trihalomethanes (TTHM), haloacetic acids (HAA5), arsenic, fluoride, nitrate and chromium (total) results here are Illinois’s own from 2020 on, with EPA’s national file for 2012 to 2019. North Tazewell PWD’s own annual report, which it must send you every year, has the contaminants this page does not show.
Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.
What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.
Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 samples are from June 3 to Dec. 3, 2025; Illinois’s results run from March 24, 2020 to Sept. 14, 2026.
Testing your own tap
What to test for at your tap
- Lead and copper. Both come mostly from a building’s own service line, solder and faucets, so a utility’s numbers can’t tell you yours. North Tazewell PWD’s latest lead sampling in EPA’s records, 2026, had a 90th percentile of 5.1 ppb: 9 in 10 of the homes it sampled were at or below that. The action level is 15 ppb, dropping to 10 ppb in November 2027, and EPA’s health goal for lead is zero. About lead.
- What North Tazewell PWD’s results flag: total trihalomethanes (TTHM), haloacetic acids (HAA5) and arsenic. These are in the water the utility sends out, so a test of your tap mostly confirms them. Include them if you want a number for your own home.
The 3 labs Illinois certifies closest to the area North Tazewell PWD serves, or a kit by mail
The 3 labs Illinois certifies closest to the area North Tazewell PWD serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.
Daily Laboratories
Peoria, IL · about 11 miles
Certified for bacteria
Pace Analytical Services, LLC - Peoria
Peoria, IL · about 11 miles
Certified for bacteria
Test, Inc.
Peru, IL · about 46 miles
Certified for bacteria
Or test by mail
Tap Score sells lab tests as kits you fill at your tap and mail back. The sample goes to Tap Score’s lab, not one near you, so check that Illinois certifies it for the test you want.
Tap Score
- Lead and Copper Water Test, with a pH test strip: $55
- Essential City Water Test, 25 metals, 4 minerals, nitrate, fluoride, hardness and pH: $189
Return shipping included.
Tap Score says each kit ships to “an accredited laboratory” but doesn’t name it, so TapBuff can’t check it against Illinois’s list.
Prices from Tap Score’s own store on Oct. 22, 2026.
What to do now
- Read up on these 4 resultsWhat each one does to health, where it comes from, and the certification claim that addresses it.Start with copper
- Get the utility’s own reportNorth Tazewell PWD must send you a water quality report every year. It covers contaminants this page does not show.How to read it
- Test your own tap for leadYour service line, solder and fixtures decide the lead at your faucet, not the utility’s average.Lead in your water: what to do
Sources
- EPA UCMR 5 occurrence data, file of Oct. 15, 2026
- EPA SDWA bulk download (SDWIS federal data), 2026 Q3
- Illinois Environmental Protection Agency, Bureau of Water, results from Jan. 2, 2020 to Oct. 13, 2026, read Oct. 17, 2026
- EPA Six-Year Review 4 compliance monitoring data, 2012 to 2019, file of Feb. 5, 2024
- Disinfectant: EPA UCMR 5 occurrence data, additional data elements, file of Oct. 15, 2026
- Certified labs: Illinois Department of Public Health, certified water microbiology laboratories, read Oct. 10, 2026; distances from the Census 2020 ZIP code tabulation area gazetteer
- Hardness: Illinois Environmental Protection Agency, Bureau of Water, results from July 12, 2018 to July 31, 2024, read Oct. 17, 2026
- Limits and goals: each contaminant’s page, with its EPA source.
- How this page is built: methodology.
PWSID IL1795780. Rebuilt from EPA data on Oct. 25, 2026.