IL American - Clarendon
What EPA’s and Illinois’s records show in this utility’s water: PFAS and lithium; nitrate, arsenic and other regulated chemicals; lead and copper; and violations since 2016, with the certification that handles each result.
- Serves
- 625 people
- Connections
- 249
- Water source
- Groundwater
- Based in
- Godfrey, IL
- County
- Dupage
- Owner
- Private
- Hardness
- Very hard
The ZIP code it serves
The short answer
1 result is above the health goal, and 1 more is above EPA’s health benchmark. The worst: Lithium, above EPA’s health benchmark. 1 health-based violation since 2016.
What handles itWhat was found
PFAS and lithium: EPA UCMR 5, samples taken from June 4, 2024 to Dec. 3, 2024.
Arsenic, total trihalomethanes (TTHM), fluoride, haloacetic acids (HAA5), nitrate and chromium (total): Illinois’s own results, samples taken from Aug. 13, 2020 to Sept. 1, 2026, with EPA’s 2012 to 2019 file for earlier years.
PFAS: None of the six PFAS in EPA’s 2024 drinking water rule was found in this utility’s samples. None of the other 23 PFAS tested for was found either.
EPA’s 2024 PFAS rule, compound by compound
| PFAS | EPA’s limit | Result |
|---|---|---|
| PFOA | 4.0 ppt | Not foundNot found in any of 2 samples, below 4 ppt |
| PFOS | 4.0 ppt | Not foundNot found in any of 2 samples, below 4 ppt |
| PFHxS | 10 ppt | Not foundNot found in any of 2 samples, below 3 ppt |
| PFNA | 10 ppt | Not foundNot found in any of 2 samples, below 4 ppt |
| HFPO-DA (GenX) | 10 ppt | Not foundNot found in any of 2 samples, below 5 ppt |
| PFBS | Index only | Not foundNot found in any of 2 samples, below 3 ppt |
| Hazard IndexPFHxS, PFNA, HFPO-DA and PFBS together | 1 | Doesn’t applyDoesn’t apply: no sampling location found two or more of the four |
| Results from EPA’s UCMR 5 sampling. “Below” is the lab’s reporting level: a result under it reads as not found, which is not the same as zero. The limits are EPA’s 2024 rule, with compliance due from 2029; EPA has since proposed changes to some of them, explained on each compound’s page. PFBS has no limit of its own and counts only toward the Hazard Index, which adds up the four, each against EPA’s health-based level, from each sampling location’s average, as EPA’s UCMR 5 summary does. It counts only where two or more of the four were found, and is above the limit from 1.5. | ||
Above the health goal1
Arsenic
Comes from the source
2.1ppb
Highest yearly average, 2021 to 2024
2024, one sample: 1.9 ppb
Averaged by year, the highest was 2.1 ppb, in 2021: below EPA’s legal limit of 10 ppb, but above its health goal of zero. In 2024, the latest year on file, its one sample was 1.9 ppb. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 2.6 ppb, in 2012.
What handles it
- NSF/ANSI 58 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
- NSF/ANSI 53 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
Above EPA’s health benchmark1
Lithium
Comes from the source
42ppb
Highest sample, Dec. 3, 2024; found in 2 of 2
The highest sample was 42 ppb, about 4.2 times EPA’s health reference level of 10 ppb. That is a screening level, not an enforceable limit.
What handles it
No certification claim covers this compound yet.
Below EPA’s limits4
Total trihalomethanes (TTHM)
Forms or is added in treatment
31ppb
Highest yearly average, 2020 to 2026
2026 average: 23.5 ppb
Averaged by year, the highest was 31 ppb, in 2025, below EPA’s legal limit of 80 ppb. Its highest single sample was 40.1 ppb. In 2026, the latest year on file, its two samples averaged 23.5 ppb. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 11.6 ppb, in 2019.
What handles it
- NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
- NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”
Fluoride
Forms or is added in treatment
0.81ppm
Highest yearly average, 2021 to 2024
2024, one sample: 0.81 ppm
Averaged by year, the highest was 0.81 ppm, in 2021, below EPA’s legal limit of 4.0 ppm. In 2024, the latest year on file, its one sample was 0.81 ppm. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 1.4 ppm, in 2015.
What handles it
- NSF/ANSI 58 look for “Fluoride Reduction”
- NSF/ANSI 53 look for “Fluoride”
Haloacetic acids (HAA5)
Forms or is added in treatment
11.2ppb
Highest yearly average, 2020 to 2026
2026 average: 4.6 ppb
Averaged by year, the highest was 11.2 ppb, in 2023, below EPA’s legal limit of 60 ppb. In 2026, the latest year on file, its two samples averaged 4.6 ppb. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 4.4 ppb, in 2019.
What handles it
No certification claim covers this compound yet.
Nitrate
Comes from the source
0.13ppm
Highest sample; found in 1 of 7
2026: not found
The highest sample, in 2021, was 0.13 ppm, below EPA’s legal limit of 10 ppm. In 2026, the latest year on file, it wasn’t found in its one sample.
What handles it
- NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
- NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”
31 compounds tested and not foundIncluding all six PFAS in EPA’s 2024 rule. Below the reporting level in every sample. Not found is not the same as zero.
From routine monitoring
- Chromium (total)
- Lead
PFAS and lithium, from EPA’s UCMR 5 sampling
- 11Cl-PF3OUdS
- 4:2 FTS
- 6:2 FTS
- 8:2 FTS
- 9Cl-PF3ONS
- ADONA
- HFPO-DA (GenX)
- NEtFOSAA
- NFDHA
- NMeFOSAA
- PFBA
- PFBS
- PFDA
- PFDoA
- PFEESA
- PFHpA
- PFHpS
- PFHxA
- PFHxS
- PFMBA
- PFMPA
- PFNA
- PFOA
- PFOS
- PFPeA
- PFPeS
- PFTA
- PFTrDA
- PFUnA
What handles it
A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box. Wording varies a little: NSF writes “Lead Reduction,” WQA just “Lead.”
- NSF/ANSI 53
Claim: Arsenic (Pentavalent)<=50 ppb Reduction
For: Arsenic
Other certifiers’ wording: Arsenic (III) (50 ppb influent level)
- NSF/ANSI 58
Claim: Arsenic (Pentavalent)<=50 ppb Reduction
For: Arsenic
Other certifiers’ wording: Arsenic (Pentavalent)<=300 ppb Reduction; Arsenic (V) (300 ppb influent level)
At the tap, or for the whole house?
These come with the water itself, so a whole-house system certified for the same claims treats every tap and shower. A filter at the tap treats drinking water for much less. How whole-house systems compare.
Filters with those claims on a certifier’s listing
Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money
Countertop reverse osmosis
- IAPMO listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 58NSF/ANSI 401checked Oct. 4, 2026
Certified for: Arsenic
Aquasana SmartFlow Reverse Osmosis (AQ-SFRO2)
Under-sink reverse osmosis
- WQA listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 58NSF/ANSI 401checked Oct. 9, 2026
Certified for: Arsenic
Brondell Capella RC250 Reverse Osmosis System
Under-sink reverse osmosis
- WQA listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 58NSF/ANSI 401checked Oct. 9, 2026
Certified for: Arsenic
Hardness
Very hard, 690 mg/L (40.4 grains per gallon), at its one sampling point, 2019 to 2025.
Hardness is calcium and magnesium. EPA sets no limit for it: it shows up as scale on fixtures and in water heaters, and as soap that won’t lather. USGS calls water above 60 mg/L moderately hard, above 120 hard and above 180 very hard.
Disinfectant
IL American - Clarendon reported disinfecting with chlorine, not chloramine, at its one sampling point, in its 2024 sampling for EPA.
Chlorine leaves water that sits out for a few days, CDC says. A filter certified for it carries a chlorine claim under NSF/ANSI 42; a shower filter, a free chlorine claim under NSF/ANSI 177. This is what the utility reported for that sampling. Its annual water quality report says what it uses now.
Violations since 2016
| Contaminant or rule | Type | Period | Measured | Status |
|---|---|---|---|---|
| Lead and Copper Rule Revisions | The required inventory of lead service lines was not completed or submitted on time.EPA: LSL Inventory | Oct. 17, 2024 | — | Resolved |
| Health-based violations only. Resolved and archived mean the utility returned to compliance or the state closed the record. 1 monitoring or reporting violation not shown. | ||||
What this report can’t tell you
Everything else. Arsenic, total trihalomethanes (TTHM), fluoride, haloacetic acids (HAA5), nitrate and chromium (total) results here are Illinois’s own from 2020 on, with EPA’s national file for 2012 to 2019. IL American - Clarendon’s own annual report, which it must send you every year, has the contaminants this page does not show.
Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.
What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.
Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 samples are from June 4, 2024 to Dec. 3, 2024; Illinois’s results run from Aug. 13, 2020 to Sept. 1, 2026.
Testing your own tap
The 3 labs Illinois certifies closest to the area IL American - Clarendon serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.
ETP Labs, Inc.
Willowbrook, IL · about 4 miles
Certified for bacteria
DuPage County Health Department
Wheaton, IL · about 9 miles
Certified for bacteria
Phigenics Analytical Services Laboratory
Warrenville, IL · about 11 miles
Certified for bacteria
Illinois Department of Public Health: Coliform bacteria and nitrate testing for private wells, with sample bottles from your local health department, or from the department's nearest regional office where there is none. You mail the sample to the lab, and results come back through the health department. Well Sampling for Coliform & Nitrate, Illinois Department of Public Health.
All 30 certified labs for IllinoisSources
- EPA UCMR 5 occurrence data, file of Oct. 15, 2026
- EPA SDWA bulk download (SDWIS federal data), 2026 Q3
- Illinois Environmental Protection Agency, Bureau of Water, results from Jan. 2, 2020 to Oct. 13, 2026, read Oct. 17, 2026
- EPA Six-Year Review 4 compliance monitoring data, 2012 to 2019, file of Feb. 5, 2024
- Disinfectant: EPA UCMR 5 occurrence data, additional data elements, file of Oct. 15, 2026
- Certified labs: Illinois Department of Public Health, certified water microbiology laboratories, read Oct. 10, 2026; distances from the Census 2020 ZIP code tabulation area gazetteer
- Hardness: Illinois Environmental Protection Agency, Bureau of Water, results from Feb. 6, 2019 to Jan. 15, 2025, read Oct. 17, 2026
- Limits and goals: each contaminant’s page, with its EPA source.
- How this page is built: methodology.
PWSID IL0435300. Rebuilt from EPA data on Oct. 18, 2026.
What to do next
- Read up on the 2 results above a lineWhat each one does to health, where it comes from, and the certification claim that addresses it.Start with Lithium
- Get the utility’s own reportIL American - Clarendon must send you a water quality report every year. It covers contaminants this page does not show.How to read it
- Test your own tap for leadYour service line, solder and fixtures decide the lead at your faucet, not the utility’s average.Lead in your water: what to do
- Compare certified filtersWhat the filters certified for these results cost over five years, cartridges included.Compare five-year costs