Skip to content
TapBuff

Parkville WD

EPA’s and Colorado’s records have results for 38 contaminants in its water; 6 were found.

Serves 7,500 people · Surface water · Leadville, CO

Serves
7,500 people
Connections
2,429
Water source
Surface water
Based in
Leadville, CO
County
Lake
Owner
Local government
The ZIP code it serves

80461

The short answer

None of the results here is above a limit in force today. That covers PFAS and lithium; nitrate, arsenic and other regulated chemicals; and lead and copper, not everything. No health-based violations on file since 2016.

Filters for lead and uranium, if you want them lower⁠

What was found

Where these results come from, and when

PFAS and lithium: EPA UCMR 5, samples taken from March 21 to Dec. 11, 2023.

Lead and copper: EPA SDWIS monitoring periods ending 2016 to 2025.

Haloacetic acids (HAA5), total trihalomethanes (TTHM), uranium, nitrate, chromium (total), arsenic and fluoride: Colorado’s own results, samples taken from Feb. 13, 2020 to Sept. 9, 2026, with EPA’s 2012 to 2019 file for earlier years.

What the lines mean
Legal limit (MCL):
Enforceable. The most a utility may deliver.
Action level:
Triggers action. If more than 10% of homes sampled are above it, the utility must act.
90th percentile:
How a lead or copper result is held against its action level: nine in ten of the homes sampled were at or below it.
Health goal (MCLG):
Not enforceable. The level with no expected risk, with a margin of safety.

PFAS: None of the six PFAS in EPA’s 2024 drinking water rule was found in this utility’s samples. None of the other 23 PFAS tested for was found either.

Below EPA’s limits, 6 results

Lead and uranium have a health goal of zero: the level with no known or expected risk. Any amount found is above it, but the goal isn’t a limit.

Legal limit (MCL):
Enforceable. The most a utility may deliver.
Action level:
Triggers action. If more than 10% of homes sampled are above it, the utility must act.
90th percentile:
How a lead or copper result is held against its action level: nine in ten of the homes sampled were at or below it.
Lead, Action level 15 ppb · health goal zero; 90th percentile 3.0 ppb

90th percentile, 2023 to 2025 · Comes from pipes, often your own

In the latest period, 9 in 10 homes sampled were at or below 3.0 ppb, below EPA’s action level of 15 ppb. The action level drops to 10 ppb on Nov. 1, 2027. EPA’s health goal for lead is zero.

What handles it

About lead
Haloacetic acids (HAA5), Legal limit 60 ppb; highest yearly average 10.9 ppb

Highest yearly average, 2020 to 2026 · 2026 average: 9.1 ppb · Forms or is added in treatment

Averaged by year, the highest was 10.9 ppb, in 2024, below EPA’s legal limit of 60 ppb. Its highest single sample was 39.1 ppb. In 2026, the latest year on file, its six samples averaged below the limit.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 17.4 ppb, in 2012.

What handles it

No certification claim covers this compound yet.

About haloacetic acids (HAA5)
Total trihalomethanes (TTHM), Legal limit 80 ppb; highest yearly average 13.4 ppb

Highest yearly average, 2020 to 2026 · 2026 average: 8.5 ppb · Forms or is added in treatment

Averaged by year, the highest was 13.4 ppb, in 2022, below EPA’s legal limit of 80 ppb. Its highest single sample was 57.8 ppb. In 2026, the latest year on file, its six samples averaged below the limit.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 27.5 ppb, in 2018.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”
About total trihalomethanes (TTHM)
Uranium, Legal limit 30 ppb · health goal zero; highest yearly average 1.6 ppb

Highest yearly average, 2022 to 2025 · 2025, one sample: 1.0 ppb · Comes from the source

Averaged by year, the highest was 1.6 ppb, in 2022, below EPA’s legal limit of 30 ppb. Its health goal is zero, so any amount found is above it; the goal isn’t a limit. In 2025, the latest year on file, its one sample was below the limit.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 1.6 ppb, in 2018.

What handles it

About uranium
Nitrate, Legal limit 10 ppm; highest 0.4 ppm

Highest sample; found in 8 of 15 · 2026: not found · Comes from the source

The highest sample, in 2025, was 0.4 ppm, below EPA’s legal limit of 10 ppm. In 2026, the latest year on file, it wasn’t found in any of its two samples.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest sample of 0.16 ppm, in 2017.

What handles it

  • NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
  • NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”
About nitrate
Chromium (total), Legal limit 100 ppb; highest yearly average 2.0 ppb

Highest yearly average, 2020 to 2026 · 2026: not found · Comes from the source

Averaged by year, the highest was 2.0 ppb, in 2024, below EPA’s legal limit of 100 ppb. In 2026, the latest year on file, it wasn’t found in any of its two samples.

What handles it

About chromium (total)
Colorado utilities above EPA’s PFAS limits⁠
32 compounds tested and not foundIncluding all six PFAS in EPA’s 2024 rule. Below the reporting level in every sample. Not found is not the same as zero.

From routine monitoring

  • Arsenic
  • Fluoride

PFAS and lithium, from EPA’s UCMR 5 sampling

  • 11Cl-PF3OUdS
  • 4:2 FTS
  • 6:2 FTS
  • 8:2 FTS
  • 9Cl-PF3ONS
  • ADONA
  • HFPO-DA (GenX)
  • Lithium
  • NEtFOSAA
  • NFDHA
  • NMeFOSAA
  • PFBA
  • PFBS
  • PFDA
  • PFDoA
  • PFEESA
  • PFHpA
  • PFHpS
  • PFHxA
  • PFHxS
  • PFMBA
  • PFMPA
  • PFNA
  • PFOA
  • PFOS
  • PFPeA
  • PFPeS
  • PFTA
  • PFTrDA
  • PFUnA

Violations since 2016

No health-based violations on file with EPA since 2016. There are 213 monitoring or reporting violations: a sample missed, late or not reported. EPA’s file runs to 2026 Q3, so a notice your utility sent since then may not be here yet.

Skip past the filters

What handles it

A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box.

At the tap, or for the whole house?

These come with the water itself, so a whole-house system certified for the same claims treats every tap and shower. A filter at the tap treats drinking water for much less. How whole-house systems compare.

Filters with those claims on a certifier’s listing

Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money

2 more filters
Compare five-year costs

Every filter for these, those that cover both first⁠

The best water filters for lead, ranked⁠

Disinfectant

Parkville WD reported disinfecting with chlorine, not chloramine, at all 2 of its sampling points, in its 2023 sampling for EPA.

What that means

Chlorine leaves water that sits out for a few days, CDC says. A filter certified for it carries a chlorine claim under NSF/ANSI 42; a shower filter, a free chlorine claim under NSF/ANSI 177. This is what the utility reported for that sampling. Its annual water quality report says what it uses now.

What this report can’t tell you

  • Everything else. Haloacetic acids (HAA5), total trihalomethanes (TTHM), uranium, nitrate, chromium (total), arsenic and fluoride results here are Colorado’s own from 2020 on, with EPA’s national file for 2012 to 2019. Parkville WD’s own annual report, which it must send you every year, has the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 samples are from March 21 to Dec. 11, 2023; Colorado’s results run from Feb. 13, 2020 to Sept. 9, 2026.

Testing your own tap

Parkville WD’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab Colorado certifies.

What to test for at your tap

  • Lead and copper. Both come mostly from a building’s own service line, solder and faucets, so a utility’s numbers can’t tell you yours. Parkville WD’s latest lead sampling in EPA’s records, 2023 to 2025, had a 90th percentile of 3.0 ppb: 9 in 10 of the homes it sampled were at or below that. The action level is 15 ppb, dropping to 10 ppb in November 2027, and EPA’s health goal for lead is zero. About lead.
The 3 labs Colorado certifies closest to the area Parkville WD serves, or a kit by mail

The 3 labs Colorado certifies closest to the area Parkville WD serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

  • Eagle River W / S District

    Avon, CO · about 27 miles

    Certified for bacteria, lead and copper, metals, radioactivity

  • GeoWater Services

    Evergreen, CO · about 54 miles

    Certified for bacteria

  • Gilpin County Public Health Agency

    Black Hawk, CO · about 60 miles

    Certified for bacteria

All 54 certified labs for Colorado⁠

Or test by mail

Tap Score sells lab tests as kits you fill at your tap and mail back. The sample goes to Tap Score’s lab, not one near you, so check that Colorado certifies it for the test you want.

  • Tap Score

    Return shipping included.

    Tap Score says each kit ships to “an accredited laboratory” but doesn’t name it, so TapBuff can’t check it against Colorado’s list.

Prices from Tap Score’s own store on Oct. 22, 2026.

What to do now

Sources

PWSID CO0133700. Rebuilt from EPA data on Oct. 25, 2026.