Galambs Mobile Home and Rv Park
What EPA’s and Colorado’s records show in this utility’s water: nitrate, arsenic and other regulated chemicals; lead and copper; and violations since 2016, with the certification that handles each result.
- Serves
- 130 people
- Connections
- 50
- Water source
- Groundwater
- Based in
- Aurora, CO
- County
- Adams
- Owner
- Private
- Hardness
- Soft
The ZIP code it serves
The short answer
Nothing in EPA’s and Colorado’s records for this utility is above a health goal. That covers nitrate, arsenic and other regulated chemicals, plus lead and copper, not everything. 3 health-based violations since 2016.
What was found
Fluoride, chromium (total), nitrate, arsenic, haloacetic acids (HAA5), total trihalomethanes (TTHM) and uranium: Colorado’s own results, samples taken from Feb. 27, 2020 to Sept. 7, 2026, with EPA’s 2012 to 2019 file for earlier years.
Below EPA’s limits3
Fluoride
Forms or is added in treatment
2.0ppm
Highest yearly average, 2020 to 2025
2025 average: 1.8 ppm
Averaged by year, the highest was 2.0 ppm, in 2020, below EPA’s legal limit of 4.0 ppm. Its highest single sample was 2.0 ppm. In 2025, the latest year on file, its two samples averaged 1.8 ppm. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 1.9 ppm, in 2016.
What handles it
- NSF/ANSI 58 look for “Fluoride Reduction”
- NSF/ANSI 53 look for “Fluoride”
Chromium (total)
Comes from the source
2.0ppb
Highest yearly average, 2020
Averaged by year, the highest was 2.0 ppb, in 2020, below EPA’s legal limit of 100 ppb. That is the only year on file.
What handles it
- NSF/ANSI 58 look for “Chromium (Hexavalent) Reduction”
- NSF/ANSI 53 look for “Chromium Reduction”
Nitrate
Comes from the source
0.2ppm
Highest sample; found in 1 of 7
2026: not found
The highest sample, in 2025, was 0.2 ppm, below EPA’s legal limit of 10 ppm. In 2026, the latest year on file, it wasn’t found in its one sample.
What handles it
- NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
- NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”
5 compounds tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
- Arsenic
- Haloacetic acids (HAA5)
- Lead
- Total trihalomethanes (TTHM)
- Uranium
Hardness
Soft, typically 11 mg/L (0.6 grains per gallon), across 2 sampling points, in 2025.
Hardness is calcium and magnesium. EPA sets no limit for it: it shows up as scale on fixtures and in water heaters, and as soap that won’t lather. USGS calls water above 60 mg/L moderately hard, above 120 hard and above 180 very hard.
Violations since 2016
| Contaminant or rule | Type | Period | Measured | Status |
|---|---|---|---|---|
| Groundwater Rule | A significant problem found in a state inspection was not fixed on time.EPA: Failure To Address Deficiency | June 5, 2022 | — | Resolved |
| Stage 1 Disinfectants and Disinfection Byproducts Rule | Treatment was not run by a certified operator as required.EPA: Treatment Technique No Certif. Operator | July 1, 2021 | — | Resolved |
| Groundwater Rule | A significant problem found in a state inspection was not fixed on time.EPA: Failure To Address Deficiency | Jan. 23, 2016 | — | Resolved |
| Health-based violations only. Resolved and archived mean the utility returned to compliance or the state closed the record. 92 monitoring or reporting violations not shown. | ||||
What this report can’t tell you
Everything else. Fluoride, chromium (total), nitrate, arsenic, haloacetic acids (HAA5), total trihalomethanes (TTHM) and uranium results here are Colorado’s own from 2020 on, with EPA’s national file for 2012 to 2019. Galambs Mobile Home and Rv Park’s own annual report, which it must send you every year, has the contaminants this page does not show.
Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.
What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.
Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; Colorado’s results run from Feb. 27, 2020 to Sept. 7, 2026.
Testing your own tap
The 3 labs Colorado certifies closest to the area Galambs Mobile Home and Rv Park serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.
SGS North America, Inc. - Denver
Denver, CO · about 13 miles
Certified for nitrate, lead and copper, metals, minerals and other inorganics
Colorado Department of Health & Environment
Denver, CO · about 16 miles
Certified for bacteria
Colorado Analytical Laboratory - Commerce City
Commerce City, CO · about 18 miles
Certified for bacteria, nitrate, lead and copper, metals, minerals and other inorganics, organic chemicals, disinfection byproducts, PFAS, radioactivity
Sources
- EPA UCMR 5 occurrence data, file of Oct. 15, 2026
- EPA SDWA bulk download (SDWIS federal data), 2026 Q3
- Colorado Department of Public Health and Environment, Water Quality Control Division, results from Jan. 3, 2020 to Oct. 6, 2026, read Oct. 17, 2026
- EPA Six-Year Review 4 compliance monitoring data, 2012 to 2019, file of Feb. 5, 2024
- Certified labs: CDPHE certified drinking water laboratories, read Oct. 16, 2026; distances from the Census 2020 ZIP code tabulation area gazetteer
- Hardness: Colorado Department of Public Health and Environment, Water Quality Control Division, results from Oct. 27, 2025 to Oct. 27, 2025, read Oct. 17, 2026
- Limits and goals: each contaminant’s page, with its EPA source.
- How this page is built: methodology.
PWSID CO0101060. Rebuilt from EPA data on Oct. 18, 2026.
What to do next
- Nothing here is above a health goalIn EPA’s and Colorado’s records for this utility. They don’t cover everything, which is why the next step matters.Every contaminant TapBuff tracks
- Get the utility’s own reportGalambs Mobile Home and Rv Park must send you a water quality report every year. It covers contaminants this page does not show.How to read it
- Test your own tap for leadYour service line, solder and fixtures decide the lead at your faucet, not the utility’s average.Lead in your water: what to do
- Decide if you want a filter at allA filter for taste or chlorine is a preference, not a need. The standards say what each kind can do.NSF/ANSI standards, decoded