Skip to content
TapBuff

Terrace Water Company

What EPA’s and California’s records show in this utility’s water: nitrate, arsenic and other regulated chemicals; lead and copper; and violations since 2016, with the certification that handles each result.

Serves
2,400 people
Connections
608
Water source
Groundwater bought from another system
Based in
Colton, CA
County
San Bernardino
Owner
Private
Hardness
Very hard
The ZIP code it serves

92324

The short answer

1 result is above the health goal. The worst: Uranium, above the health goal. No health-based violations on file since 2016.

What handles it

What was found

Nitrate, fluoride, total trihalomethanes (TTHM) and haloacetic acids (HAA5): California’s own results, samples taken from Feb. 7, 2020 to Aug. 5, 2025, with EPA’s 2012 to 2019 file for earlier years.

Uranium, arsenic and chromium (total): EPA’s compliance monitoring file, samples taken from Nov. 1, 2013 to Nov. 6, 2018. Newer results are in the utility’s annual water quality report.

Above the health goal1

Uranium

Comes from the source

Above the health goal

8.3ppb

Highest yearly average, 2013 to 2017

2017 average: 7.4 ppb

Averaged by year, the highest was 8.3 ppb, in 2015: below EPA’s legal limit of 30 ppb, but above its health goal of zero. Its highest single sample was 10.7 ppb. In 2017, the latest year on file, its five samples averaged 7.4 ppb.

What handles it

Below EPA’s limits3

Nitrate

Comes from the source

Below EPA’s limits

0.83ppm

One sample

2020, one sample: 0.83 ppm

The highest sample, in 2020, was 0.83 ppm, below EPA’s legal limit of 10 ppm. That is the only year on file, and its one sample was 0.83 ppm. Earlier, from 2012 to 2019, EPA’s file shows a highest sample of 2.7 ppm, in 2012.

What handles it

  • NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
  • NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”

Fluoride

Forms or is added in treatment

Below EPA’s limits

0.28ppm

Highest yearly average, 2020

Averaged by year, the highest was 0.28 ppm, in 2020, below EPA’s legal limit of 4.0 ppm. That is the only year on file. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 0.3 ppm, in 2017.

What handles it

Total trihalomethanes (TTHM)

Forms or is added in treatment

Below EPA’s limits

0.55ppb

Highest yearly average, 2020 to 2025

2025: not found

Averaged by year, the highest was 0.55 ppb, in 2023, below EPA’s legal limit of 80 ppb. Its highest single sample was 1.1 ppb. In 2025, the latest year on file, it wasn’t found in any of its two samples.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”
4 compounds tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
  • Arsenic
  • Chromium (total)
  • Haloacetic acids (HAA5)
  • Lead

What handles it

A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box. Wording varies a little: NSF writes “Lead Reduction,” WQA just “Lead.”

At the tap, or for the whole house?

These come with the water itself, so a whole-house system certified for the same claims treats every tap and shower. A filter at the tap treats drinking water for much less. How whole-house systems compare.

Filters with those claims on a certifier’s listing

None of the filters TapBuff has checked so far carry these claims. Search the certifier listings for the claim above.

Compare five-year costs

Hardness

Very hard, 280 mg/L (16.4 grains per gallon), at its one sampling point, in 2020.

Hardness is calcium and magnesium. EPA sets no limit for it: it shows up as scale on fixtures and in water heaters, and as soap that won’t lather. USGS calls water above 60 mg/L moderately hard, above 120 hard and above 180 very hard.

Violations since 2016

No health-based violations on file with EPA since 2016. There is 1 monitoring or reporting violation: a sample missed, late or not reported.

What this report can’t tell you

  • Everything else. Nitrate, fluoride, total trihalomethanes (TTHM) and haloacetic acids (HAA5) results here are California’s own from 2020 on, with EPA’s national file for 2012 to 2019. Uranium, arsenic and chromium (total) come from EPA’s file alone, which ends in 2019. Terrace Water Company’s own annual report, which it must send you every year, has newer results for those and the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; California’s results run from Feb. 7, 2020 to Aug. 5, 2025; EPA’s compliance samples are from Nov. 1, 2013 to Nov. 6, 2018.

Testing your own tap

Terrace Water Company’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab California certifies.

The 3 labs California certifies closest to the area Terrace Water Company serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

  • BSK Associates - San Bernardino Analytical Laboratory

    San Bernardino, CA · about 2 miles

    Certified for bacteria

    (559) 497-2888

  • Clinical Laboratory of San Bernardino, Inc.

    Grand Terrace, CA · about 2 miles

    Certified for bacteria, nitrate, lead and copper, metals, minerals and other inorganics, organic chemicals, disinfection byproducts, radioactivity

    (909) 825-7693

  • Babcock Laboratories, Inc.

    Riverside, CA · about 6 miles

    Certified for bacteria, nitrate, lead and copper, metals, minerals and other inorganics, organic chemicals, disinfection byproducts, PFAS, radioactivity

    (951) 653-3351

All 145 certified labs for California