What EPA’s and California’s records show in this utility’s water: nitrate, arsenic and other regulated chemicals; lead and copper; and violations since 2016, with the certification that handles each result.
- Serves
- 146 people
- Connections
- 52
- Water source
- Groundwater
- Based in
- Dana Point, CA
- County
- Tuolumne
- Owner
- Private
- Hardness
- Soft
The ZIP code it serves
The short answer
Nothing in EPA’s and California’s records for this utility is above a health goal. That covers nitrate, arsenic and other regulated chemicals, plus lead and copper, not everything. 2 health-based violations since 2016.
What was found
Nitrate, chromium (total), fluoride, arsenic and total trihalomethanes (TTHM): California’s own results, samples taken from Sept. 22, 2020 to June 10, 2026, with EPA’s 2012 to 2019 file for earlier years.
Below EPA’s limits3
Nitrate
Comes from the source
2.8ppm
Highest sample; found in 8 of 8
2026, one sample: 1.2 ppm
The highest sample, in 2020, was 2.8 ppm, below EPA’s legal limit of 10 ppm. In 2026, the latest year on file, its one sample was 1.2 ppm. Earlier, from 2012 to 2019, EPA’s file shows a highest sample of 3.7 ppm, in 2018.
What handles it
- NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
- NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”
Chromium (total)
Comes from the source
5.1ppb
Highest yearly average, 2020 to 2025
2025: not found
Averaged by year, the highest was 5.1 ppb, in 2020, below EPA’s legal limit of 100 ppb. In 2025, the latest year on file, it wasn’t found in its one sample.
What handles it
- NSF/ANSI 58 look for “Chromium (Hexavalent) Reduction”
- NSF/ANSI 53 look for “Chromium Reduction”
Fluoride
Forms or is added in treatment
0.14ppm
Highest yearly average, 2022 to 2025
2025: not found
Averaged by year, the highest was 0.14 ppm, in 2022, below EPA’s legal limit of 4.0 ppm. In 2025, the latest year on file, it wasn’t found in its one sample. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 0.41 ppm, in 2016.
What handles it
- NSF/ANSI 58 look for “Fluoride Reduction”
- NSF/ANSI 53 look for “Fluoride”
3 compounds tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
- Arsenic
- Lead
- Total trihalomethanes (TTHM)
Hardness
Soft, 53 mg/L (3.1 grains per gallon), at its one sampling point, 2019 to 2025.
Hardness is calcium and magnesium. EPA sets no limit for it: it shows up as scale on fixtures and in water heaters, and as soap that won’t lather. USGS calls water above 60 mg/L moderately hard, above 120 hard and above 180 very hard.
Violations since 2016
| Contaminant or rule | Type | Period | Measured | Status |
|---|---|---|---|---|
| Lead and Copper Rule Revisions | The required inventory of lead service lines was not completed or submitted on time.EPA: LSL Inventory | Oct. 17, 2024 | — | Unaddressed |
| Revised Total Coliform Rule | E. coli was confirmed in the water system.EPA: Maximum Contaminant Level Violation, E. coli (RTCR) | July 1, 2016 to July 31, 2016 | — | Resolved |
| Health-based violations only. Resolved and archived mean the utility returned to compliance or the state closed the record. 2 monitoring or reporting violations not shown. | ||||
What this report can’t tell you
Everything else. Nitrate, chromium (total), fluoride, arsenic and total trihalomethanes (TTHM) results here are California’s own from 2020 on, with EPA’s national file for 2012 to 2019. Ponderosa Mobile Home Park’s own annual report, which it must send you every year, has the contaminants this page does not show.
Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.
What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.
Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; California’s results run from Sept. 22, 2020 to June 10, 2026.
Testing your own tap
The 3 labs California certifies closest to the area Ponderosa Mobile Home Park serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.
Precision Enviro-Tech
Twain Harte, CA · about 8 miles
Certified for bacteria
49er Water Laboratory
Jackson, CA · about 34 miles
Certified for bacteria, nitrate, minerals and other inorganics
Aemtek, Inc.
Modesto, CA · about 41 miles
Certified for bacteria
Sources
- EPA UCMR 5 occurrence data, file of Oct. 15, 2026
- EPA SDWA bulk download (SDWIS federal data), 2026 Q3
- California State Water Resources Control Board, Division of Drinking Water, results from Jan. 1, 2020 to July 17, 2026, read Oct. 8, 2026
- EPA Six-Year Review 4 compliance monitoring data, 2012 to 2019, file of Feb. 5, 2024
- Certified labs: California State Water Resources Control Board, ELAP accredited laboratories and their fields of accreditation, read Oct. 17, 2026; distances from the Census 2020 ZIP code tabulation area gazetteer
- Hardness: California State Water Resources Control Board, Division of Drinking Water, results from Dec. 10, 2019 to Nov. 5, 2025, read Oct. 10, 2026
- Limits and goals: each contaminant’s page, with its EPA source.
- How this page is built: methodology.
PWSID CA5500092. Rebuilt from EPA data on Oct. 18, 2026.
What to do next
- Nothing here is above a health goalIn EPA’s and California’s records for this utility. They don’t cover everything, which is why the next step matters.Every contaminant TapBuff tracks
- Get the utility’s own reportPonderosa Mobile Home Park must send you a water quality report every year. It covers contaminants this page does not show.How to read it
- Test your own tap for leadYour service line, solder and fixtures decide the lead at your faucet, not the utility’s average.Lead in your water: what to do