North Tahoe PUD - Main

EPA’s and California’s records have results for 38 contaminants in its water; 5 were found.

Serves 6,321 people · Surface water · Tahoe Vista, CA · Hardness: varies by source

Serves
6,321 people
Connections
3,763
Water source
Surface water
Based in
Tahoe Vista, CA
County
Placer
Owner
Local government
Hardness
Varies by source
The 4 ZIP codes it serves

96140, 96143, 96145, 96148

The short answer

None of the results here is above a limit in force today. That covers PFAS and lithium; nitrate, arsenic and other regulated chemicals; and lead and copper, not everything. No health-based violations on file since 2016.

Filters for lead and uranium, if you want them lower⁠

What was found

Where these results come from, and when

PFAS and lithium: EPA UCMR 5, samples taken from Jan. 8, 2024 to Jan. 7, 2025.

Lead and copper: EPA SDWIS monitoring periods ending 2006 to 2025.

Copper: EPA’s file records a utility’s copper only when it exceeds the action level. The last here was 1.4 ppm, for the period ending Dec. 31, 1994. None since is on file, so it is not counted as a current finding.

Total trihalomethanes (TTHM), haloacetic acids (HAA5), nitrate, uranium, arsenic, chromium (total) and fluoride: California’s own results, samples taken from Sept. 10, 2020 to Sept. 18, 2025, with EPA’s 2012 to 2019 file for earlier years.

What the lines mean
Legal limit (MCL):
Enforceable. The most a utility may deliver.
Action level:
Triggers action. If more than 10% of homes sampled are above it, the utility must act.
90th percentile:
How a lead or copper result is held against its action level: nine in ten of the homes sampled were at or below it.
Health goal (MCLG):
Not enforceable. The level with no expected risk, with a margin of safety.

PFAS: None of the six PFAS in EPA’s 2024 drinking water rule was found in this utility’s samples. None of the other 23 PFAS tested for was found either.

Below EPA’s limits, 5 results

Lead and uranium have a health goal of zero: the level with no known or expected risk. Any amount found is above it, but the goal isn’t a limit.

Legal limit (MCL):
Enforceable. The most a utility may deliver.
Action level:
Triggers action. If more than 10% of homes sampled are above it, the utility must act.
90th percentile:
How a lead or copper result is held against its action level: nine in ten of the homes sampled were at or below it.
Total trihalomethanes (TTHM), Legal limit 80 ppb; highest yearly average 16.4 ppb

Highest yearly average, 2021 to 2025 · 2025 average: 12.7 ppb · Forms or is added in treatment

Averaged by year, the highest was 16.4 ppb, in 2021, below EPA’s legal limit of 80 ppb. Its highest single sample was 35 ppb. In 2025, the latest year on file, its three samples averaged below the limit.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 15.4 ppb, in 2013.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”
About total trihalomethanes (TTHM)
Haloacetic acids (HAA5), Legal limit 60 ppb; highest yearly average 8.9 ppb

Highest yearly average, 2021 to 2025 · 2025 average: 8.9 ppb · Forms or is added in treatment

Averaged by year, the highest was 8.9 ppb, in 2022, below EPA’s legal limit of 60 ppb. Its highest single sample was 11.2 ppb. In 2025, the latest year on file, its two samples averaged below the limit.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 6.4 ppb, in 2014.

What handles it

No certification claim covers this compound yet.

About haloacetic acids (HAA5)
Lead, Action level 15 ppb · health goal zero; 90th percentile 1.4 ppb

90th percentile, 2023 to 2025 · Comes from pipes, often your own

In the latest period, 9 in 10 homes sampled were at or below 1.4 ppb, below EPA’s action level of 15 ppb. The action level drops to 10 ppb on Nov. 1, 2027. EPA’s health goal for lead is zero.

What handles it

About lead
Nitrate, Legal limit 10 ppm; highest 0.3 ppm

Highest sample; found in 1 of 12 · 2025: not found · Comes from the source

The highest sample, in 2024, was 0.3 ppm, below EPA’s legal limit of 10 ppm. In 2025, the latest year on file, it wasn’t found in any of its two samples.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest sample of 0.12 ppm, in 2017.

What handles it

  • NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
  • NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”
About nitrate
Uranium, Legal limit 30 ppb · health goal zero; highest yearly average 0.75 ppb

Highest yearly average, 2023 · Comes from the source

Averaged by year, the highest was 0.75 ppb, in 2023, below EPA’s legal limit of 30 ppb. Its health goal is zero, so any amount found is above it; the goal isn’t a limit. Its highest single sample was 1.5 ppb. That is the only year on file.

What handles it

About uranium
California utilities above EPA’s PFAS limits⁠
33 compounds tested and not foundIncluding all six PFAS in EPA’s 2024 rule. Below the reporting level in every sample. Not found is not the same as zero.

From routine monitoring

  • Arsenic
  • Chromium (total)
  • Fluoride

PFAS and lithium, from EPA’s UCMR 5 sampling

  • 11Cl-PF3OUdS
  • 4:2 FTS
  • 6:2 FTS
  • 8:2 FTS
  • 9Cl-PF3ONS
  • ADONA
  • HFPO-DA (GenX)
  • Lithium
  • NEtFOSAA
  • NFDHA
  • NMeFOSAA
  • PFBA
  • PFBS
  • PFDA
  • PFDoA
  • PFEESA
  • PFHpA
  • PFHpS
  • PFHxA
  • PFHxS
  • PFMBA
  • PFMPA
  • PFNA
  • PFOA
  • PFOS
  • PFPeA
  • PFPeS
  • PFTA
  • PFTrDA
  • PFUnA

Violations since 2016

No health-based violations on file with EPA since 2016. EPA’s file runs to 2026 Q3, so a notice your utility sent since then may not be here yet.

Skip past the filters

What handles it

A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box.

At the tap, or for the whole house?

These come with the water itself, so a whole-house system certified for the same claims treats every tap and shower. A filter at the tap treats drinking water for much less. How whole-house systems compare.

Filters with those claims on a certifier’s listing

Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money

2 more filters
Compare five-year costs

Every filter for these, those that cover both first⁠

The best water filters for lead, ranked⁠

Hardness

Soft to moderately hard depending on the source, 32 to 80 mg/L (1.9 to 4.6 grains per gallon), across 2 sampling points, in 2023.

Hardness is calcium and magnesium. EPA sets no limit for it: it shows up as scale on fixtures and in water heaters, and as soap that won’t lather. USGS calls water above 60 mg/L moderately hard, above 120 hard and above 180 very hard.

Disinfectant

North Tahoe PUD - Main reported disinfecting with chlorine, not chloramine, at all 2 of its sampling points, in its 2024 to 2025 sampling for EPA. It also reported ultraviolet light.

What that means

Chlorine leaves water that sits out for a few days, CDC says. A filter certified for it carries a chlorine claim under NSF/ANSI 42; a shower filter, a free chlorine claim under NSF/ANSI 177. This is what the utility reported for that sampling. Its annual water quality report says what it uses now.

What this report can’t tell you

  • Everything else. Total trihalomethanes (TTHM), haloacetic acids (HAA5), nitrate, uranium, arsenic, chromium (total) and fluoride results here are California’s own from 2020 on, with EPA’s national file for 2012 to 2019. North Tahoe PUD - Main’s own annual report, which it must send you every year, has the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 samples are from Jan. 8, 2024 to Jan. 7, 2025; California’s results run from Sept. 10, 2020 to Sept. 18, 2025.

Testing your own tap

North Tahoe PUD - Main’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab California certifies.

What to test for at your tap

  • Lead and copper. Both come mostly from a building’s own service line, solder and faucets, so a utility’s numbers can’t tell you yours. North Tahoe PUD - Main’s latest lead sampling in EPA’s records, 2023 to 2025, had a 90th percentile of 1.4 ppb: 9 in 10 of the homes it sampled were at or below that. The action level is 15 ppb, dropping to 10 ppb in November 2027, and EPA’s health goal for lead is zero. About lead.
The 3 labs California certifies closest to the area North Tahoe PUD - Main serves, or a kit by mail

The 3 labs California certifies closest to the area North Tahoe PUD - Main serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

  • SGS Silver State Analytical Lab - Reno

    Reno, NV · about 27 miles

    Certified for bacteria, nitrate, lead and copper, metals, minerals and other inorganics, radioactivity

    (775) 857-2400

  • Cranmer Engineering, Inc.

    Grass Valley, CA · about 51 miles

    Certified for bacteria, nitrate, lead and copper, metals, minerals and other inorganics

    (530) 273-7284

  • Onterris Laboratories, LLC

    El Dorado Hills, CA · about 66 miles

    Certified for organic chemicals, PFAS

    (916) 673-1520

All 145 certified labs for California⁠

Or test by mail

Tap Score sells lab tests as kits you fill at your tap and mail back. The sample goes to Tap Score’s lab, not one near you, so check that California certifies it for the test you want.

  • Tap Score

    Return shipping included.

    Tap Score says each kit ships to “an accredited laboratory” but doesn’t name it, so TapBuff can’t check it against California’s list.

Prices from Tap Score’s own store on Oct. 22, 2026.

What to do now

Sources

PWSID CA3110001. Rebuilt from EPA data on Oct. 25, 2026.