Naval Base Ventura County, Port Hueneme
EPA’s and California’s records have results for 8 contaminants in its water; 5 were found.
Serves 3,500 people · Surface water bought from another system · Point Mugu, CA · Hardness: very hard
- Serves
- 3,500 people
- Connections
- 658
- Water source
- Surface water bought from another system
- Based in
- Point Mugu, CA
- County
- Ventura
- Owner
- Federal government
- Hardness
- Very hard
The short answer
None of the results here is above a limit in force today. That covers nitrate, arsenic and other regulated chemicals, plus lead and copper, not everything. No health-based violations on file since 2016.
What was found
Where these results come from, and when
Copper: EPA’s file records a utility’s copper only when it exceeds the action level. The last here was 1.6 ppm, for the period ending Dec. 31, 1996. None since is on file, so it is not counted as a current finding.
Total trihalomethanes (TTHM), nitrate, fluoride, uranium, haloacetic acids (HAA5), arsenic and chromium (total): California’s own results, samples taken from Jan. 16, 2020 to June 17, 2026, with EPA’s 2012 to 2019 file for earlier years.
What the lines mean
- Legal limit (MCL):
- Enforceable. The most a utility may deliver.
- Health goal (MCLG):
- Not enforceable. The level with no expected risk, with a margin of safety.
Below EPA’s limits, 5 results
Uranium has a health goal of zero: the level with no known or expected risk. Any amount found is above it, but the goal isn’t a limit.
- Legal limit (MCL):
- Enforceable. The most a utility may deliver.
Total trihalomethanes (TTHM), Legal limit 80 ppb; highest yearly average 43.2 ppb
Highest yearly average, 2020 to 2026 · 2026 average: 36 ppb · Forms or is added in treatment
Averaged by year, the highest was 43.2 ppb, in 2023, below EPA’s legal limit of 80 ppb. Its highest single sample was 90 ppb. In 2026, the latest year on file, its 24 samples averaged below the limit. EPA recorded no violation for total trihalomethanes (TTHM) at this utility since 2020.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest yearly average of 57.9 ppb, in 2019.
What handles it
- NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
- NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”
Nitrate, Legal limit 10 ppm; highest 2.2 ppm
Highest sample; found in 1 of 6 · 2025: not found · Comes from the source
The highest sample, in 2024, was 2.2 ppm, below EPA’s legal limit of 10 ppm. In 2025, the latest year on file, it wasn’t found in its one sample.
What handles it
- NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
- NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”
Fluoride, Legal limit 4.0 ppm; highest yearly average 0.7 ppm
Highest yearly average, 2021 · Forms or is added in treatment
Averaged by year, the highest was 0.7 ppm, in 2021, below EPA’s legal limit of 4.0 ppm. That is the only year on file.
What handles it
- NSF/ANSI 58 look for “Fluoride Reduction”
- NSF/ANSI 53 look for “Fluoride”
Uranium, Legal limit 30 ppb · health goal zero; highest yearly average 5.2 ppb
Highest yearly average, 2021 · Comes from the source
Averaged by year, the highest was 5.2 ppb, in 2021, below EPA’s legal limit of 30 ppb. Its health goal is zero, so any amount found is above it; the goal isn’t a limit. That is the only year on file.
What handles it
- NSF/ANSI 58 look for “Uranium”
Haloacetic acids (HAA5), Legal limit 60 ppb; highest yearly average 9.1 ppb
Highest yearly average, 2020 to 2026 · Forms or is added in treatment
Averaged by year, the highest was 9.1 ppb, in 2026, below EPA’s legal limit of 60 ppb. Its highest single sample was 21 ppb. That was also the latest year on file.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest yearly average of 9.6 ppb, in 2019.
What handles it
No certification claim covers this compound yet.
3 compounds tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
- Arsenic
- Chromium (total)
- Lead
Violations since 2016
No health-based violations on file with EPA since 2016. There are 2 monitoring or reporting violations: a sample missed, late or not reported. EPA’s file runs to 2026 Q3, so a notice your utility sent since then may not be here yet.
What handles it
A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box.
- NSF/ANSI 58
Claim: Uranium
For: Uranium
At the tap, or for the whole house?
These come with the water itself, so a whole-house system certified for the same claims treats every tap and shower. A filter at the tap treats drinking water for much less. How whole-house systems compare.
Filters with those claims on a certifier’s listing
None of the filters TapBuff has checked so far carry these claims. Search the certifier listings for the claim above.
Compare five-year costsHardness
Very hard, 421 mg/L (24.6 grains per gallon), at its one sampling point, in 2021.
Hardness is calcium and magnesium. EPA sets no limit for it: it shows up as scale on fixtures and in water heaters, and as soap that won’t lather. USGS calls water above 60 mg/L moderately hard, above 120 hard and above 180 very hard.
What this report can’t tell you
Everything else. Total trihalomethanes (TTHM), nitrate, fluoride, uranium, haloacetic acids (HAA5), arsenic and chromium (total) results here are California’s own from 2020 on, with EPA’s national file for 2012 to 2019. Naval Base Ventura County, Port Hueneme’s own annual report, which it must send you every year, has the contaminants this page does not show.
Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.
What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.
Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; California’s results run from Jan. 16, 2020 to June 17, 2026.
Testing your own tap
What to test for at your tap
- Lead and copper. Both come mostly from a building’s own service line, solder and faucets, so a utility’s numbers can’t tell you yours. Naval Base Ventura County, Port Hueneme’s latest lead sampling in EPA’s records, 2023 to 2025, had a 90th percentile of 0 ppb across the homes it sampled. The action level is 15 ppb, dropping to 10 ppb in November 2027, and EPA’s health goal for lead is zero. About lead.
The 3 labs California certifies closest to the area Naval Base Ventura County, Port Hueneme serves, or a kit by mail
The 3 labs California certifies closest to the area Naval Base Ventura County, Port Hueneme serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.
Ventura County Public Health Laboratory
Oxnard, CA · about 6 miles
Certified for bacteria
Camrosa Water District Wastewater Laboratory
Camarillo, CA · about 6 miles
Certified for bacteria
Capco Analytical Services
Ventura, CA · about 9 miles
Certified for bacteria, nitrate, metals, minerals and other inorganics
Or test by mail
Tap Score sells lab tests as kits you fill at your tap and mail back. The sample goes to Tap Score’s lab, not one near you, so check that California certifies it for the test you want.
Tap Score
- Lead and Copper Water Test, with a pH test strip: $55
- Essential City Water Test, 25 metals, 4 minerals, nitrate, fluoride, hardness and pH: $189
Return shipping included.
Tap Score says each kit ships to “an accredited laboratory” but doesn’t name it, so TapBuff can’t check it against California’s list.
Prices from Tap Score’s own store on Oct. 22, 2026.
What to do now
- Nothing here is above an EPA limit or health benchmarkIn EPA’s and California’s records for this utility. They don’t cover everything, which is why the next step matters.Every contaminant TapBuff tracks
- Get the utility’s own reportNaval Base Ventura County, Port Hueneme must send you a water quality report every year. It covers contaminants this page does not show.How to read it
- Test your own tap for leadIts latest lead sampling found none at the 90th percentile, but your own service line, solder and fixtures decide the lead at your faucet.Lead in your water: what to do
Sources
- EPA UCMR 5 occurrence data, file of Oct. 15, 2026
- EPA SDWA bulk download (SDWIS federal data), 2026 Q3
- California State Water Resources Control Board, Division of Drinking Water, results from Jan. 1, 2020 to July 17, 2026, read Oct. 8, 2026
- EPA Six-Year Review 4 compliance monitoring data, 2012 to 2019, file of Feb. 5, 2024
- Certified labs: California State Water Resources Control Board, ELAP accredited laboratories and their fields of accreditation, read Oct. 17, 2026; distances from the Census 2020 ZIP code tabulation area gazetteer
- Hardness: California State Water Resources Control Board, Division of Drinking Water, results from March 17 to 17, 2021, read Oct. 10, 2026
- Limits and goals: each contaminant’s page, with its EPA source.
- How this page is built: methodology.
PWSID CA5610701. Rebuilt from EPA data on Oct. 25, 2026.