Skip to content
TapBuff

Little Baldy Water

What EPA’s and California’s records show in this utility’s water: nitrate, arsenic and other regulated chemicals; lead and copper; and violations since 2016, with the certification that handles each result.

Serves
55 people
Connections
36
Water source
Groundwater
Based in
Llano, CA
County
Los Angeles
Owner
Private
Hardness
Very hard
The ZIP code it serves

93544

The short answer

1 result is above the health goal. The worst: Uranium, above the health goal. 1 health-based violation since 2016.

What handles it

What was found

Uranium, fluoride, nitrate, haloacetic acids (HAA5), total trihalomethanes (TTHM), arsenic and chromium (total): California’s own results, samples taken from Jan. 21, 2020 to Dec. 23, 2025, with EPA’s 2012 to 2019 file for earlier years.

Above the health goal1

Uranium

Comes from the source

Above the health goal

7.5ppb

Highest yearly average, 2020 to 2025

Averaged by year, the highest was 7.5 ppb, in 2025: below EPA’s legal limit of 30 ppb, but above its health goal of zero. Its highest single sample was 7.9 ppb. That was also the latest year on file.

What handles it

Below EPA’s limits4

Fluoride

Forms or is added in treatment

Below EPA’s limits

1.1ppm

Highest yearly average, 2021 to 2025

Averaged by year, the highest was 1.1 ppm, in 2025, below EPA’s legal limit of 4.0 ppm. Its highest single sample was 1.2 ppm. That was also the latest year on file. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 1.1 ppm, in 2015.

What handles it

Nitrate

Comes from the source

Below EPA’s limits

1.8ppm

Highest sample; found in 8 of 10

2025 average: 1.0 ppm

The highest sample, in 2021, was 1.8 ppm, below EPA’s legal limit of 10 ppm. In 2025, the latest year on file, its two samples averaged 1.0 ppm. Earlier, from 2012 to 2019, EPA’s file shows a highest sample of 2.5 ppm, in 2015.

What handles it

  • NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
  • NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”

Haloacetic acids (HAA5)

Forms or is added in treatment

Below EPA’s limits

5.2ppb

Highest yearly average, 2020

Averaged by year, the highest was 5.2 ppb, in 2020, below EPA’s legal limit of 60 ppb. That is the only year on file.

What handles it

No certification claim covers this compound yet.

Total trihalomethanes (TTHM)

Forms or is added in treatment

Below EPA’s limits

1.8ppb

Highest yearly average, 2020 to 2025

2025: not found

Averaged by year, the highest was 1.8 ppb, in 2020, below EPA’s legal limit of 80 ppb. Its highest single sample was 5.5 ppb. In 2025, the latest year on file, it wasn’t found in any of its two samples.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”
3 compounds tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
  • Arsenic
  • Chromium (total)
  • Lead

What handles it

A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box. Wording varies a little: NSF writes “Lead Reduction,” WQA just “Lead.”

At the tap, or for the whole house?

These come with the water itself, so a whole-house system certified for the same claims treats every tap and shower. A filter at the tap treats drinking water for much less. How whole-house systems compare.

Filters with those claims on a certifier’s listing

None of the filters TapBuff has checked so far carry these claims. Search the certifier listings for the claim above.

Compare five-year costs

Hardness

Very hard, typically 433 mg/L (25.3 grains per gallon), across 2 sampling points, 2021 to 2025.

Hardness is calcium and magnesium. EPA sets no limit for it: it shows up as scale on fixtures and in water heaters, and as soap that won’t lather. USGS calls water above 60 mg/L moderately hard, above 120 hard and above 180 very hard.

Violations since 2016

Contaminant or ruleTypePeriodMeasuredStatus
Lead and Copper Rule RevisionsThe required inventory of lead service lines was not completed or submitted on time.EPA: LSL InventoryOct. 17, 2024—Unaddressed
Health-based violations only. Resolved and archived mean the utility returned to compliance or the state closed the record. 2 monitoring or reporting violations not shown.

What this report can’t tell you

  • Everything else. Uranium, fluoride, nitrate, haloacetic acids (HAA5), total trihalomethanes (TTHM), arsenic and chromium (total) results here are California’s own from 2020 on, with EPA’s national file for 2012 to 2019. Little Baldy Water’s own annual report, which it must send you every year, has the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; California’s results run from Jan. 21, 2020 to Dec. 23, 2025.

Testing your own tap

Little Baldy Water’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab California certifies.

The 3 labs California certifies closest to the area Little Baldy Water serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

  • Geo-Monitor, Inc

    Hesperia, CA · about 27 miles

    Certified for bacteria

    (760) 244-3481

  • Eurofins Pomona

    Pomona, CA · about 30 miles

    Certified for bacteria, nitrate, lead and copper, metals, minerals and other inorganics, organic chemicals, disinfection byproducts, PFAS, radioactivity

    (626) 386-1100

  • Enviro-Chem, Inc.

    Pomona, CA · about 32 miles

    Certified for metals

    (909) 590-5905

All 145 certified labs for California

Sources