June Lake PUD - Down Canyon
What EPA’s and California’s records show in this utility’s water: nitrate, arsenic and other regulated chemicals; lead and copper; and violations since 2016, with the certification that handles each result.
- Serves
- 310 people
- Connections
- 404
- Water source
- Surface water
- Based in
- June Lake, CA
- County
- Mono
- Owner
- Local government
- Hardness
- Soft
The ZIP code it serves
The short answer
2 results are above the health goal. The worst: Lead, above the health goal. 3 health-based violations since 2016.
What handles itWhat was found
Lead and copper: EPA SDWIS monitoring periods ending 2006 to 2024. Lead at 0.39 mg/L (2003) is left out of this report: more than 20 times the action level, it looks like µg/L entered as mg/L.
Arsenic, haloacetic acids (HAA5), total trihalomethanes (TTHM), nitrate, fluoride, chromium (total) and uranium: California’s own results, samples taken from Jan. 20, 2020 to Oct. 29, 2025, with EPA’s 2012 to 2019 file for earlier years.
Above the health goal2
Lead
Comes from pipes, often your own
2.0ppb
90th percentile, 2022 to 2024
In the latest period, 9 in 10 homes sampled were at or below 2.0 ppb, below EPA’s action level of 15 ppb. The action level drops to 10 ppb on Nov. 1, 2027. EPA’s health goal for lead is zero.
What handles it
- NSF/ANSI 53 look for “Lead Reduction”
- NSF/ANSI 58 look for “Lead Reduction”
Arsenic
Comes from the source
0.7ppb
Highest yearly average, 2020 to 2025
Averaged by year, the highest was 0.7 ppb, in 2025: below EPA’s legal limit of 10 ppb, but above its health goal of zero. Its highest single sample was 2.0 ppb. That was also the latest year on file.
What handles it
- NSF/ANSI 58 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
- NSF/ANSI 53 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
Below EPA’s limits4
Haloacetic acids (HAA5)
Forms or is added in treatment
33.8ppb
Highest yearly average, 2020 to 2025
2025 average: 23.5 ppb
Averaged by year, the highest was 33.8 ppb, in 2020, below EPA’s legal limit of 60 ppb. Its highest single sample was 56 ppb. In 2025, the latest year on file, its two samples averaged 23.5 ppb. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 35.5 ppb, in 2017.
What handles it
No certification claim covers this compound yet.
Total trihalomethanes (TTHM)
Forms or is added in treatment
16.1ppb
Highest yearly average, 2020 to 2025
2025 average: 7.8 ppb
Averaged by year, the highest was 16.1 ppb, in 2021, below EPA’s legal limit of 80 ppb. Its highest single sample was 37 ppb. In 2025, the latest year on file, its four samples averaged 7.8 ppb. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 30.3 ppb, in 2016.
What handles it
- NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
- NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”
Nitrate
Comes from the source
0.1ppm
Highest sample; found in 2 of 12
2025: not found
The highest sample, in 2020, was 0.1 ppm, below EPA’s legal limit of 10 ppm. In 2025, the latest year on file, it wasn’t found in any of its two samples.
What handles it
- NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
- NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”
Fluoride
Forms or is added in treatment
0.033ppm
Highest yearly average, 2020 to 2025
2025: not found
Averaged by year, the highest was 0.033 ppm, in 2020, below EPA’s legal limit of 4.0 ppm. Its highest single sample was 0.066 ppm. In 2025, the latest year on file, it wasn’t found in any of its two samples. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 0.061 ppm, in 2014.
What handles it
- NSF/ANSI 58 look for “Fluoride Reduction”
- NSF/ANSI 53 look for “Fluoride”
2 compounds tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
- Chromium (total)
- Uranium
What handles it
A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box. Wording varies a little: NSF writes “Lead Reduction,” WQA just “Lead.”
- NSF/ANSI 53
Claims: Lead Reduction, Arsenic (Pentavalent)<=50 ppb Reduction
For: Lead, Arsenic
Other certifiers’ wording: Arsenic (III) (50 ppb influent level)
- NSF/ANSI 58
Claims: Lead Reduction, Arsenic (Pentavalent)<=50 ppb Reduction
For: Lead, Arsenic
Other certifiers’ wording: Arsenic (Pentavalent)<=300 ppb Reduction; Arsenic (V) (300 ppb influent level)
At the tap, or for the whole house?
Lead and copper usually come from pipes and fixtures inside or near your home. A whole-house system sits where water enters, so it cannot catch what your own plumbing adds after it. For those, the filter that counts is the one at the tap. How whole-house systems compare.
Filters with those claims on a certifier’s listing
Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money
Aquasana SmartFlow Reverse Osmosis (AQ-SFRO2)
Under-sink reverse osmosis
- WQA listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 58NSF/ANSI 401checked Oct. 9, 2026
Certified for: Lead, Arsenic
Brondell Capella RC250 Reverse Osmosis System
Under-sink reverse osmosis
- WQA listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 58NSF/ANSI 401checked Oct. 9, 2026
Certified for: Lead, Arsenic
Countertop reverse osmosis
- IAPMO listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 58NSF/ANSI 401checked Oct. 4, 2026
Certified for: Lead, Arsenic
Brita Tahoe Pitcher with Elite Filter (OB60, OB06)
Pitcher
- WQA listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 401checked Oct. 13, 2026
- IAPMO listing:NSF/ANSI 53checked Oct. 13, 2026
Certified for: Lead
Hardness
Soft, typically 26 mg/L (1.5 grains per gallon), across 2 sampling points, 2019 to 2025.
Hardness is calcium and magnesium. EPA sets no limit for it: it shows up as scale on fixtures and in water heaters, and as soap that won’t lather. USGS calls water above 60 mg/L moderately hard, above 120 hard and above 180 very hard.
Violations since 2016
| Contaminant or rule | Type | Period | Measured | Status |
|---|---|---|---|---|
| Lead and Copper Rule Revisions | The required inventory of lead service lines was not completed or submitted on time.EPA: LSL Inventory | Oct. 17, 2024 | — | Unaddressed |
| Surface Water Treatment Rule | Required treatment for surface water or groundwater was not met.EPA: Treatment Technique (SWTR and GWR) | June 1, 2023 to June 30, 2023 | — | Archived |
| Surface Water Treatment Rule | Required treatment for surface water or groundwater was not met.EPA: Treatment Technique (SWTR and GWR) | May 1, 2023 to May 31, 2023 | — | Archived |
| Health-based violations only. Resolved and archived mean the utility returned to compliance or the state closed the record. 1 monitoring or reporting violation not shown. | ||||
What this report can’t tell you
Everything else. Arsenic, haloacetic acids (HAA5), total trihalomethanes (TTHM), nitrate, fluoride, chromium (total) and uranium results here are California’s own from 2020 on, with EPA’s national file for 2012 to 2019. June Lake PUD - Down Canyon’s own annual report, which it must send you every year, has the contaminants this page does not show.
Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.
What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.
Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; California’s results run from Jan. 20, 2020 to Oct. 29, 2025.
Testing your own tap
The 2 labs California certifies closest to the area June Lake PUD - Down Canyon serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.
Precision Enviro-Tech
Twain Harte, CA · about 64 miles
Certified for bacteria
SGS North America, Inc.
Clovis, CA · about 74 miles
Certified for nitrate, lead and copper, metals, minerals and other inorganics, organic chemicals, disinfection byproducts, PFAS
Sources
- EPA UCMR 5 occurrence data, file of Oct. 15, 2026
- EPA SDWA bulk download (SDWIS federal data), 2026 Q3
- California State Water Resources Control Board, Division of Drinking Water, results from Jan. 1, 2020 to July 17, 2026, read Oct. 8, 2026
- EPA Six-Year Review 4 compliance monitoring data, 2012 to 2019, file of Feb. 5, 2024
- Certified labs: California State Water Resources Control Board, ELAP accredited laboratories and their fields of accreditation, read Oct. 17, 2026; distances from the Census 2020 ZIP code tabulation area gazetteer
- Hardness: California State Water Resources Control Board, Division of Drinking Water, results from Sept. 30, 2019 to Oct. 29, 2025, read Oct. 10, 2026
- Limits and goals: each contaminant’s page, with its EPA source.
- How this page is built: methodology.
PWSID CA2610004. Rebuilt from EPA data on Oct. 18, 2026.
What to do next
- Read up on the 2 results above a lineWhat each one does to health, where it comes from, and the certification claim that addresses it.Start with Lead
- Get the utility’s own reportJune Lake PUD - Down Canyon must send you a water quality report every year. It covers contaminants this page does not show.How to read it
- Test your own tap for leadYour service line, solder and fixtures decide the lead at your faucet, not the utility’s average.Lead in your water: what to do