- Serves
- 5,161
- Connections
- 1,841
- Water source
- Surface water bought from another system
- Based in
- Buellton, CA
- County
- Santa Barbara
- Owner
- Local government
The ZIP code it serves
PWSID CA4210018 · EPA data
Read this first
- Copper In the latest period, 9 in 10 homes sampled were at or below 1.7 ppm, above the 1.3 ppm action level.
- Lithium was found in four of 8 samples, highest 27.3 ppb. Above EPA’s health reference level of 10 ppb, a screening level rather than an enforceable limit.
No health-based violations on file since 2016.
What handles itWhat was found, stop by stop
- Below the health goal
- Above the health goal
- Above the legal limit
- No federal data
At the source
EPA UCMR 5 sampled this utility for 29 PFAS and lithium from Feb. 12, 2025 to April 15, 2026. Each tick under a result’s line is one sample where it was found, dated when you point at it.
- Health reference level 1027.3
Above EPA’s health reference level of 10 ppb, a screening level rather than an enforceable limit.
What handles it: No certification claim covers this compound yet.
In treatment
No federal results for this stop. Disinfection byproduct, chlorine and fluoride levels are in City of Buellton Water Division’s own annual report, which it must send you every year.
In the pipes
Lead and copper, from the homes the utility samples. Your own service line, solder and fixtures decide yours.
- Limit and goal 1.31.7
In the latest period, 9 in 10 homes sampled were at or below 1.7 ppm, above the 1.3 ppm action level.
EPA SDWIS, lead and copper monitoring periods ending 1993 to 2008. The line stops at the latest period; each tick under it is an earlier one.
NSF/ANSI 53 · Look for: Copper Reduction
NSF/ANSI 58 · Look for: Copper Reduction
At your tap
The last stretch is your own plumbing. A certified lab test is the only way to know what reaches your glass. Lead in your water: what to do
Tested and not found
Below EPA’s minimum reporting level in every sample taken from Feb. 12, 2025 to April 15, 2026. Not found means not measured above that level, which is not the same as zero.
All 30 compounds tested and not found
- 11Cl-PF3OUdS
- 4:2 FTS
- 6:2 FTS
- 8:2 FTS
- 9Cl-PF3ONS
- ADONA
- HFPO-DA (GenX)
- Lead
- NEtFOSAA
- NFDHA
- NMeFOSAA
- PFBA
- PFBS
- PFDA
- PFDoA
- PFEESA
- PFHpA
- PFHpS
- PFHxA
- PFHxS
- PFMBA
- PFMPA
- PFNA
- PFOA
- PFOS
- PFPeA
- PFPeS
- PFTA
- PFTrDA
- PFUnA
Violations since 2016
No health-based violations on file with EPA since 2016.
What handles it
A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box. Wording varies a little: NSF writes “Lead Reduction,” WQA just “Lead.”
At the tap, or for the whole house?
Lead and copper usually come from pipes and fixtures inside or near your home. A whole-house system sits where water enters, so it cannot catch what your own plumbing adds after it. For those, the filter that counts is the one at the tap. How whole-house systems compare.
Filters with those claims on a certifier’s listing
TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money
Brita Tahoe Pitcher with Original Filter (OB60, OB03)
Pitcher
- WQA listing:NSF/ANSI 42NSF/ANSI 53checked Oct. 4, 2026
Certified for: Copper
PUR PLUS 11-Cup Pitcher (PPT111W)
Pitcher
- NSF listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 401checked Oct. 4, 2026
- WQA listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 401checked Oct. 4, 2026
- IAPMO listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 401checked Oct. 4, 2026
Certified for: Copper
Countertop reverse osmosis
- IAPMO listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 58NSF/ANSI 401checked Oct. 4, 2026
Certified for: Copper
What this report cannot tell you
- Levels of everything else. Federal bulk data carries results for PFAS, lithium, lead and copper, and violations for the rest. Nitrate, arsenic, disinfection byproducts and other levels are in City of Buellton Water Division’s own annual report, which it must send you every year.
- Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.
- Anything after the latest data. SDWIS data is from 2026 Q2; UCMR 5 samples are from Feb. 12, 2025 to April 15, 2026.
Other California utilities
- Los Angeles - City, Dept. of Water & Power3.9 million
- East Bay MUD1.4 million
- City of San Diego1.4 million
- San Jose Water1 million
- SFPUC City Distribution Division848,019
- Eastern Municipal WD666,581
- City of Fresno545,716
- City of Sacramento Main527,979
- Long Beach Utilities Department466,772
- Irvine Ranch Water District444,800
- City of Anaheim348,593
- Alameda County Water District344,000
Sources
- EPA UCMR 5 occurrence data, file of Aug. 27, 2026
- EPA SDWA bulk download (SDWIS federal data), 2026 Q2
- Limits and goals: each contaminant’s page, with its EPA source.
- How this page is built: methodology.