Cabazon Water District
What EPA’s and California’s records show in this utility’s water: nitrate, arsenic and other regulated chemicals; lead and copper; and violations since 2016, with the certification that handles each result.
- Serves
- 1,900 people
- Connections
- 958
- Water source
- Groundwater
- Based in
- Cabazon, CA
- County
- Riverside
- Owner
- Local government
- Hardness
- Varies by source
The ZIP code it serves
The short answer
2 results are above the health goal. The worst: Uranium, above the health goal. No health-based violations on file since 2016.
What handles itWhat was found
Lead and copper: EPA SDWIS monitoring periods ending 2002 to 2023.
Uranium, nitrate, fluoride, chromium (total), total trihalomethanes (TTHM), arsenic and haloacetic acids (HAA5): California’s own results, samples taken from May 13, 2020 to June 17, 2026, with EPA’s 2012 to 2019 file for earlier years.
Above the health goal2
Uranium
Comes from the source
2.8ppb
Highest yearly average, 2024
Averaged by year, the highest was 2.8 ppb, in 2024: below EPA’s legal limit of 30 ppb, but above its health goal of zero. Its highest single sample was 3.4 ppb. That is the only year on file. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 2.8 ppb, in 2012.
What handles it
- NSF/ANSI 58 look for “Uranium”
Lead
Comes from pipes, often your own
1.2ppb
90th percentile, 2021 to 2023
In the latest period, 9 in 10 homes sampled were at or below 1.2 ppb, below EPA’s action level of 15 ppb. The action level drops to 10 ppb on Nov. 1, 2027. EPA’s health goal for lead is zero.
What handles it
- NSF/ANSI 53 look for “Lead Reduction”
- NSF/ANSI 58 look for “Lead Reduction”
Below EPA’s limits4
Nitrate
Comes from the source
3.6ppm
Highest sample; found in 24 of 24
2026 average: 2.0 ppm
The highest sample, in 2025, was 3.6 ppm, below EPA’s legal limit of 10 ppm. In 2026, the latest year on file, its three samples averaged 2.0 ppm. Earlier, from 2012 to 2019, EPA’s file shows a highest sample of 2.5 ppm, in 2018.
What handles it
- NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
- NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”
Fluoride
Forms or is added in treatment
0.77ppm
Highest yearly average, 2020 to 2026
2026 average: 0.4 ppm
Averaged by year, the highest was 0.77 ppm, in 2022, below EPA’s legal limit of 4.0 ppm. In 2026, the latest year on file, its two samples averaged 0.4 ppm. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 0.8 ppm, in 2012.
What handles it
- NSF/ANSI 58 look for “Fluoride Reduction”
- NSF/ANSI 53 look for “Fluoride”
Chromium (total)
Comes from the source
5.3ppb
Highest yearly average, 2020 to 2026
2026: not found
Averaged by year, the highest was 5.3 ppb, in 2025, below EPA’s legal limit of 100 ppb. In 2026, the latest year on file, it wasn’t found in any of its two samples. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 6.3 ppb, in 2015.
What handles it
- NSF/ANSI 58 look for “Chromium (Hexavalent) Reduction”
- NSF/ANSI 53 look for “Chromium Reduction”
Total trihalomethanes (TTHM)
Forms or is added in treatment
3.7ppb
Highest yearly average, 2020 to 2025
2025 average: 1.7 ppb
Averaged by year, the highest was 3.7 ppb, in 2024, below EPA’s legal limit of 80 ppb. Its highest single sample was 11 ppb. In 2025, the latest year on file, its three samples averaged 1.7 ppb. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 3.0 ppb, in 2017.
What handles it
- NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
- NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”
2 compounds tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
- Arsenic
- Haloacetic acids (HAA5)
What handles it
A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box. Wording varies a little: NSF writes “Lead Reduction,” WQA just “Lead.”
- NSF/ANSI 53
Claim: Lead Reduction
For: Lead
- NSF/ANSI 58
Claims: Uranium, Lead Reduction
For: Uranium, Lead
At the tap, or for the whole house?
Lead and copper usually come from pipes and fixtures inside or near your home. A whole-house system sits where water enters, so it cannot catch what your own plumbing adds after it. For those, the filter that counts is the one at the tap. How whole-house systems compare.
Filters with those claims on a certifier’s listing
Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money
Brita Tahoe Pitcher with Elite Filter (OB60, OB06)
Pitcher
- WQA listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 401checked Oct. 13, 2026
- IAPMO listing:NSF/ANSI 53checked Oct. 13, 2026
Certified for: Lead
Brita Everyday Pitcher with Elite Filter (OB46, OB06)
Pitcher
- WQA listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 401checked Oct. 13, 2026
Certified for: Lead
PUR PLUS 11-Cup Pitcher (PPT111W)
Pitcher
- NSF listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 401checked Oct. 4, 2026
- WQA listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 401checked Oct. 4, 2026
- IAPMO listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 401checked Oct. 4, 2026
Certified for: Lead
ZeroWater 10 Cup Pitcher (ZP-010)
Pitcher
- IAPMO listing:NSF/ANSI 42NSF/ANSI 53checked Oct. 4, 2026
Certified for: Lead
Culligan 10-Cup Pitcher with ZeroWater Technology (ZEROP10)
Pitcher
- IAPMO listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 401checked Oct. 9, 2026
Certified for: Lead
Hardness
Hard to very hard depending on the source, 170 to 195 mg/L (9.9 to 11.4 grains per gallon), across 4 sampling points, 2020 to 2026.
Hardness is calcium and magnesium. EPA sets no limit for it: it shows up as scale on fixtures and in water heaters, and as soap that won’t lather. USGS calls water above 60 mg/L moderately hard, above 120 hard and above 180 very hard.
Violations since 2016
No health-based violations on file with EPA since 2016. There are 3 monitoring or reporting violations: a sample missed, late or not reported.
What this report can’t tell you
Everything else. Uranium, nitrate, fluoride, chromium (total), total trihalomethanes (TTHM), arsenic and haloacetic acids (HAA5) results here are California’s own from 2020 on, with EPA’s national file for 2012 to 2019. Cabazon Water District’s own annual report, which it must send you every year, has the contaminants this page does not show.
Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.
What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.
Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; California’s results run from May 13, 2020 to June 17, 2026.
Testing your own tap
The 3 labs California certifies closest to the area Cabazon Water District serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.
Babcock Laboratories, Inc.
Riverside, CA · about 30 miles
Certified for bacteria, nitrate, lead and copper, metals, minerals and other inorganics, organic chemicals, disinfection byproducts, PFAS, radioactivity
BSK Associates - San Bernardino Analytical Laboratory
San Bernardino, CA · about 31 miles
Certified for bacteria
Clinical Laboratory of San Bernardino, Inc.
Grand Terrace, CA · about 33 miles
Certified for bacteria, nitrate, lead and copper, metals, minerals and other inorganics, organic chemicals, disinfection byproducts, radioactivity
Sources
- EPA UCMR 5 occurrence data, file of Oct. 15, 2026
- EPA SDWA bulk download (SDWIS federal data), 2026 Q3
- California State Water Resources Control Board, Division of Drinking Water, results from Jan. 1, 2020 to July 17, 2026, read Oct. 8, 2026
- EPA Six-Year Review 4 compliance monitoring data, 2012 to 2019, file of Feb. 5, 2024
- Certified labs: California State Water Resources Control Board, ELAP accredited laboratories and their fields of accreditation, read Oct. 17, 2026; distances from the Census 2020 ZIP code tabulation area gazetteer
- Hardness: California State Water Resources Control Board, Division of Drinking Water, results from May 13, 2020 to May 20, 2026, read Oct. 10, 2026
- Limits and goals: each contaminant’s page, with its EPA source.
- How this page is built: methodology.
PWSID CA3310047. Rebuilt from EPA data on Oct. 18, 2026.
What to do next
- Read up on the 2 results above a lineWhat each one does to health, where it comes from, and the certification claim that addresses it.Start with Uranium
- Get the utility’s own reportCabazon Water District must send you a water quality report every year. It covers contaminants this page does not show.How to read it
- Test your own tap for leadYour service line, solder and fixtures decide the lead at your faucet, not the utility’s average.Lead in your water: what to do
- Compare certified filtersWhat the filters certified for these results cost over five years, cartridges included.Compare five-year costs