Skip to content
TapBuff

East Central Baldwin County WS & Fpa

What EPA’s and Alabama’s records show in this utility’s water: PFAS and lithium; nitrate, arsenic and other regulated chemicals; lead and copper; and violations since 2016, with the certification that handles each result.

Serves
7,254 people
Connections
2,418
Water source
Groundwater
Based in
Robertsdale, AL
County
Baldwin
Owner
Local government
Hardness
Soft
The 4 ZIP codes it serves

36551, 36567, 36574, 36580

The short answer

Nothing in EPA’s and Alabama’s records for this utility is above a health goal. That covers PFAS and lithium; nitrate, arsenic and other regulated chemicals; and lead and copper, not everything. No health-based violations on file since 2016.

What was found

PFAS and lithium: EPA UCMR 5, samples taken from June 6, 2023 to Dec. 5, 2023.

Haloacetic acids (HAA5), total trihalomethanes (TTHM), nitrate, arsenic, chromium (total) and fluoride: Alabama’s own results, samples taken from Jan. 31, 2020 to July 15, 2026, with EPA’s 2012 to 2019 file for earlier years.

PFAS: None of the six PFAS in EPA’s 2024 drinking water rule was found in this utility’s samples. None of the other 23 PFAS tested for was found either.

EPA’s 2024 PFAS rule, compound by compound

PFASEPA’s limitResult
PFOA4.0 pptNot foundNot found in any of 4 samples, below 4 ppt
PFOS4.0 pptNot foundNot found in any of 4 samples, below 4 ppt
PFHxS10 pptNot foundNot found in any of 4 samples, below 3 ppt
PFNA10 pptNot foundNot found in any of 4 samples, below 4 ppt
HFPO-DA (GenX)10 pptNot foundNot found in any of 4 samples, below 5 ppt
PFBSIndex onlyNot foundNot found in any of 4 samples, below 3 ppt
Hazard IndexPFHxS, PFNA, HFPO-DA and PFBS together1Doesn’t applyDoesn’t apply: no sampling location found two or more of the four
Results from EPA’s UCMR 5 sampling. “Below” is the lab’s reporting level: a result under it reads as not found, which is not the same as zero. The limits are EPA’s 2024 rule, with compliance due from 2029; EPA has since proposed changes to some of them, explained on each compound’s page. PFBS has no limit of its own and counts only toward the Hazard Index, which adds up the four, each against EPA’s health-based level, from each sampling location’s average, as EPA’s UCMR 5 summary does. It counts only where two or more of the four were found, and is above the limit from 1.5.

Below EPA’s limits3

Haloacetic acids (HAA5)

Forms or is added in treatment

Below EPA’s limits

12.6ppb

Highest yearly average, 2020 to 2026

2026 average: 5.0 ppb

Averaged by year, the highest was 12.6 ppb, in 2022, below EPA’s legal limit of 60 ppb. Its highest single sample was 24 ppb. In 2026, the latest year on file, its two samples averaged 5.0 ppb. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 0.76 ppb, in 2015.

What handles it

No certification claim covers this compound yet.

Total trihalomethanes (TTHM)

Forms or is added in treatment

Below EPA’s limits

14.2ppb

Highest yearly average, 2020 to 2026

2026 average: 4.5 ppb

Averaged by year, the highest was 14.2 ppb, in 2023, below EPA’s legal limit of 80 ppb. Its highest single sample was 24 ppb. In 2026, the latest year on file, its two samples averaged 4.5 ppb. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 3.4 ppb, in 2017.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”

Nitrate

Comes from the source

Below EPA’s limits

0.9ppm

Highest sample; found in 13 of 14

2026 average: 0.52 ppm

The highest sample, in 2024, was 0.9 ppm, below EPA’s legal limit of 10 ppm. In 2026, the latest year on file, its two samples averaged 0.52 ppm. Earlier, from 2012 to 2019, EPA’s file shows a highest sample of 0.84 ppm, in 2019.

What handles it

  • NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
  • NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”
Alabama utilities above EPA’s PFAS limits
34 compounds tested and not foundIncluding all six PFAS in EPA’s 2024 rule. Below the reporting level in every sample. Not found is not the same as zero.

From routine monitoring

  • Arsenic
  • Chromium (total)
  • Fluoride
  • Lead

PFAS and lithium, from EPA’s UCMR 5 sampling

  • 11Cl-PF3OUdS
  • 4:2 FTS
  • 6:2 FTS
  • 8:2 FTS
  • 9Cl-PF3ONS
  • ADONA
  • HFPO-DA (GenX)
  • Lithium
  • NEtFOSAA
  • NFDHA
  • NMeFOSAA
  • PFBA
  • PFBS
  • PFDA
  • PFDoA
  • PFEESA
  • PFHpA
  • PFHpS
  • PFHxA
  • PFHxS
  • PFMBA
  • PFMPA
  • PFNA
  • PFOA
  • PFOS
  • PFPeA
  • PFPeS
  • PFTA
  • PFTrDA
  • PFUnA

Hardness

Soft, 18 mg/L (1.1 grains per gallon), at its one sampling point, 2016 to 2025.

Hardness is calcium and magnesium. EPA sets no limit for it: it shows up as scale on fixtures and in water heaters, and as soap that won’t lather. USGS calls water above 60 mg/L moderately hard, above 120 hard and above 180 very hard.

Disinfectant

East Central Baldwin County WS & Fpa reported disinfecting with chlorine, not chloramine, at all 2 of its sampling points, in its 2023 sampling for EPA.

Chlorine leaves water that sits out for a few days, CDC says. A filter certified for it carries a chlorine claim under NSF/ANSI 42; a shower filter, a free chlorine claim under NSF/ANSI 177. This is what the utility reported for that sampling. Its annual water quality report says what it uses now.

Violations since 2016

No health-based violations on file with EPA since 2016. There are 59 monitoring or reporting violations: a sample missed, late or not reported.

What this report can’t tell you

  • Everything else. Haloacetic acids (HAA5), total trihalomethanes (TTHM), nitrate, arsenic, chromium (total) and fluoride results here are Alabama’s own from 2020 on, with EPA’s national file for 2012 to 2019. East Central Baldwin County WS & Fpa’s own annual report, which it must send you every year, has the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 samples are from June 6, 2023 to Dec. 5, 2023; Alabama’s results run from Jan. 31, 2020 to July 15, 2026.

Testing your own tap

East Central Baldwin County WS & Fpa’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab Alabama certifies.

The 3 labs Alabama certifies closest to the area East Central Baldwin County WS & Fpa serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

  • Eurofins Pensacola

    Pensacola, FL · about 24 miles

    (850) 474-1001 ext. 6242

  • Mobile Water Service Laboratory

    Mobile, AL · about 25 miles

    Certified for bacteria

    (251) 378-3521

  • Pace Analytical Services - Mobile

    Mobile, AL · about 33 miles

    Certified for bacteria

    (504) 305-3611

Alabama Department of Public Health: Bacteria testing for private wells. Call your county health department to have an environmentalist collect the sample, or collect it yourself in a container from the county health department; there may be a collection fee and a testing fee. Well Water, Alabama Department of Public Health.

All 64 certified labs for Alabama

Sources

PWSID AL0001770. Rebuilt from EPA data on Oct. 18, 2026.