Skip to content
TapBuff

Sun Harbor Water District #3

What EPA’s and Washington’s records show in this utility’s water: nitrate, arsenic and other regulated chemicals; lead and copper; and violations since 2016, with the certification that handles each result.

Serves
187 people
Connections
88
Water source
Groundwater
Based in
Burbank, WA
County
Walla Walla
Owner
Local government
Hardness
Varies by source
The ZIP code it serves

99323

The short answer

2 results are above the health goal. The worst: Arsenic, above the health goal. No health-based violations on file since 2016.

What handles it

What was found

Lead and copper: EPA SDWIS monitoring periods ending 2003 to 2024.

Arsenic, nitrate, fluoride, total trihalomethanes (TTHM), haloacetic acids (HAA5) and chromium (total): Washington’s own results, samples taken from Jan. 28, 2020 to Sept. 22, 2026, with EPA’s 2012 to 2019 file for earlier years.

Above the health goal2

Arsenic

Comes from the source

Above the health goal

5.7ppb

Highest yearly average, 2025

Averaged by year, the highest was 5.7 ppb, in 2025: below EPA’s legal limit of 10 ppb, but above its health goal of zero. Its highest single sample was 6.4 ppb. That is the only year on file. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 4.4 ppb, in 2016.

What handles it

  • NSF/ANSI 58 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
  • NSF/ANSI 53 look for “Arsenic (Pentavalent)<=50 ppb Reduction”

Lead

Comes from pipes, often your own

Above the health goal

0.4ppb

90th percentile, 2022 to 2024

In the latest period, 9 in 10 homes sampled were at or below 0.4 ppb, below EPA’s action level of 15 ppb. The action level drops to 10 ppb on Nov. 1, 2027. EPA’s health goal for lead is zero.

What handles it

Below EPA’s limits4

Nitrate

Comes from the source

Below EPA’s limits

10ppm

Highest sample; found in 212 of 212

2026 average: 6.0 ppm

The highest sample, in 2020, was 10 ppm, below EPA’s legal limit of 10 ppm. In 2026, the latest year on file, its 22 samples averaged 6.0 ppm. Earlier, from 2012 to 2019, EPA’s file shows a highest sample of 12 ppm, in 2018.

What handles it

  • NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
  • NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”

Fluoride

Forms or is added in treatment

Below EPA’s limits

3.2ppm

Highest yearly average, 2020 to 2026

2026 average: 2.8 ppm

Averaged by year, the highest was 3.2 ppm, in 2024, below EPA’s legal limit of 4.0 ppm. Its highest single sample was 5.6 ppm. In 2026, the latest year on file, its 11 samples averaged 2.8 ppm. EPA recorded no violation for fluoride at this utility since 2020. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 4.0 ppm, in 2016, and EPA recorded violations in 2012 and 2013.

What handles it

Total trihalomethanes (TTHM)

Forms or is added in treatment

Below EPA’s limits

12.2ppb

Highest yearly average, 2021 to 2025

2025, one sample: 8.7 ppb

Averaged by year, the highest was 12.2 ppb, in 2021, below EPA’s legal limit of 80 ppb. In 2025, the latest year on file, its one sample was 8.7 ppb. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 11.9 ppb, in 2018.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”

Haloacetic acids (HAA5)

Forms or is added in treatment

Below EPA’s limits

2.0ppb

Highest yearly average, 2021 to 2025

2025, one sample: 1.6 ppb

Averaged by year, the highest was 2.0 ppb, in 2021, below EPA’s legal limit of 60 ppb. In 2025, the latest year on file, its one sample was 1.6 ppb. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 2.6 ppb, in 2018.

What handles it

No certification claim covers this compound yet.

One compound tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
  • Chromium (total)

What handles it

A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box. Wording varies a little: NSF writes “Lead Reduction,” WQA just “Lead.”

  • NSF/ANSI 53

    Claims: Arsenic (Pentavalent)<=50 ppb Reduction, Lead Reduction

    For: Arsenic, Lead

    Other certifiers’ wording: Arsenic (III) (50 ppb influent level)

  • NSF/ANSI 58

    Claims: Arsenic (Pentavalent)<=50 ppb Reduction, Lead Reduction

    For: Arsenic, Lead

    Other certifiers’ wording: Arsenic (Pentavalent)<=300 ppb Reduction; Arsenic (V) (300 ppb influent level)

At the tap, or for the whole house?

Lead and copper usually come from pipes and fixtures inside or near your home. A whole-house system sits where water enters, so it cannot catch what your own plumbing adds after it. For those, the filter that counts is the one at the tap. How whole-house systems compare.

Filters with those claims on a certifier’s listing

Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money

Compare five-year costs

The best reverse osmosis systems, ranked

The best water filters for lead, ranked

Hardness

Soft to very hard depending on the source, 52 to 270 mg/L (3 to 15.8 grains per gallon), across 2 sampling points, in 2025.

Hardness is calcium and magnesium. EPA sets no limit for it: it shows up as scale on fixtures and in water heaters, and as soap that won’t lather. USGS calls water above 60 mg/L moderately hard, above 120 hard and above 180 very hard.

Violations since 2016

No health-based violations on file with EPA since 2016. There are 149 monitoring or reporting violations: a sample missed, late or not reported.

What this report can’t tell you

  • Everything else. Arsenic, nitrate, fluoride, total trihalomethanes (TTHM), haloacetic acids (HAA5) and chromium (total) results here are Washington’s own from 2020 on, with EPA’s national file for 2012 to 2019. Sun Harbor Water District #3’s own annual report, which it must send you every year, has the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; Washington’s results run from Jan. 28, 2020 to Sept. 22, 2026.

Testing your own tap

Sun Harbor Water District #3’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab Washington certifies.

The 3 labs Washington certifies closest to the area Sun Harbor Water District #3 serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

  • Matrix Sciences International Inc. dba KTL

    Pasco, WA · about 14 miles

    Certified for nitrate, lead and copper, metals, minerals and other inorganics

    (509) 547-3838

  • RJ Lee Group, Inc. Columbia Basin Analytical Laboratories

    Pasco, WA · about 14 miles

    Certified for nitrate, lead and copper, metals, minerals and other inorganics

    (509) 792-1951

  • Benton-Franklin Health District Lab

    Kennewick, WA · about 15 miles

    Certified for bacteria, nitrate, minerals and other inorganics

    (509) 460-4206

All 84 certified labs for Washington

Sources

PWSID WA5385129. Rebuilt from EPA data on Oct. 18, 2026.