Skip to content
TapBuff

Ncsa - Schuyler

What EPA’s and CDC’s records show in this utility’s water: nitrate, arsenic and other regulated chemicals; lead and copper; and violations since 2016, with the certification that handles each result.

Serves
480 people
Connections
160
Water source
Surface water
Based in
Lovingston, VA
County
Nelson
Owner
Local government
The ZIP code it serves

22969

The short answer

2 results are above EPA’s legal limit, and 1 more is above the health goal. The worst: Haloacetic acids (HAA5), above the legal limit. 15 health-based violations since 2016.

What handles it

What was found

Lead and copper: EPA SDWIS monitoring periods ending 2004 to 2025.

Arsenic: Virginia’s yearly averages per water system, as CDC’s Environmental Public Health Tracking Network publishes them, 2021 to 2023.

Haloacetic acids (HAA5) and total trihalomethanes (TTHM): EPA’s violation records from 2020 on, with EPA’s 2012 to 2019 file for earlier years.

Fluoride, nitrate and chromium (total): EPA’s compliance monitoring file, samples taken from Aug. 23, 2012 to May 22, 2019. Newer results are in the utility’s annual water quality report.

Above the legal limit2

Haloacetic acids (HAA5)

Forms or is added in treatment

Above the legal limit

79ppb

Limit violation, 2024

EPA recorded three violations of the legal limit for haloacetic acids (HAA5) at this utility in 2024 and 2025. The highest measured level, for July 1, 2024 to Sept. 30, 2024, was an average of 79 ppb, above EPA’s legal limit of 60 ppb. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 83.6 ppb, in 2015, and EPA recorded violations in 2016, 2017 and 2018.

What handles it

No certification claim covers this compound yet.

Total trihalomethanes (TTHM)

Forms or is added in treatment

Above the legal limit

95ppb

Limit violation, 2023

EPA recorded six violations of the legal limit for total trihalomethanes (TTHM) at this utility in 2022, 2023 and 2025. The highest measured level, for Jan. 1, 2023 to March 31, 2023, was an average of 95 ppb, above EPA’s legal limit of 80 ppb. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 60.9 ppb, in 2017.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”

Above the health goal1

Lead

Comes from pipes, often your own

Above the health goal

0.79ppb

90th percentile, 2023 to 2025

In the latest period, 9 in 10 homes sampled were at or below 0.79 ppb, below EPA’s action level of 15 ppb. The action level drops to 10 ppb on Nov. 1, 2027. EPA’s health goal for lead is zero.

What handles it

Below EPA’s limits2

Fluoride

Forms or is added in treatment

Below EPA’s limits

1.7ppm

Highest yearly average, 2012 to 2019

2019, one sample: 0.44 ppm

Averaged by year, the highest was 1.7 ppm, in 2015, below EPA’s legal limit of 4.0 ppm. In 2019, the latest year on file, its one sample was 0.44 ppm.

What handles it

Nitrate

Comes from the source

Below EPA’s limits

0.11ppm

Highest sample; found in 7 of 8

2019, one sample: 0.052 ppm

The highest sample, in 2014, was 0.11 ppm, below EPA’s legal limit of 10 ppm. In 2019, the latest year on file, its one sample was 0.052 ppm.

What handles it

  • NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
  • NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”
2 compounds tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
  • Arsenic
  • Chromium (total)

What handles it

A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box. Wording varies a little: NSF writes “Lead Reduction,” WQA just “Lead.”

  • NSF/ANSI 53

    Claims: Trihalomethanes (TTHM) Reduction, Lead Reduction

    For: Total trihalomethanes (TTHM), Lead

    Other certifiers’ wording: VOC Reduction

  • NSF/ANSI 58

    Claims: Trihalomethanes (TTHM) Reduction, Lead Reduction

    For: Total trihalomethanes (TTHM), Lead

At the tap, or for the whole house?

Lead and copper usually come from pipes and fixtures inside or near your home. A whole-house system sits where water enters, so it cannot catch what your own plumbing adds after it. For those, the filter that counts is the one at the tap. How whole-house systems compare.

Filters with those claims on a certifier’s listing

Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money

Compare five-year costs

The best water filters for lead, ranked

Violations since 2016

Contaminant or ruleTypePeriodMeasuredStatus
TTHMThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageApril 1, 2025 to June 30, 202585 UG/LResolved
TTHMThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJan. 1, 2025 to March 31, 202584 UG/LResolved
Total Haloacetic Acids (HAA5)The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJan. 1, 2025 to March 31, 202566 UG/LResolved
Total Haloacetic Acids (HAA5)The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageOct. 1, 2024 to Dec. 31, 202470 UG/LResolved
Total Haloacetic Acids (HAA5)The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJuly 1, 2024 to Sept. 30, 202479 UG/LResolved
TTHMThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageApril 1, 2023 to June 30, 202391 UG/LResolved
TTHMThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJan. 1, 2023 to March 31, 202395 UG/LResolved
TTHMThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageOct. 1, 2022 to Dec. 31, 202293 UG/LResolved
TTHMThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJuly 1, 2022 to Sept. 30, 202293 UG/LResolved
Total Haloacetic Acids (HAA5)The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJan. 1, 2018 to March 31, 20180.063 MG/LResolved
Total Haloacetic Acids (HAA5)The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageOct. 1, 2017 to Dec. 31, 20170.065 MG/LResolved
Total Haloacetic Acids (HAA5)The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJuly 1, 2017 to Sept. 30, 201769 UG/LResolved
Total Haloacetic Acids (HAA5)The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageApril 1, 2017 to June 30, 201761 UG/LResolved
Total Haloacetic Acids (HAA5)The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJan. 1, 2017 to March 31, 20170.068 MG/LResolved
Total Haloacetic Acids (HAA5)The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageApril 1, 2016 to June 30, 20160.076 MG/LResolved
Health-based violations only. Resolved and archived mean the utility returned to compliance or the state closed the record. 6 monitoring or reporting violations not shown.

What this report can’t tell you

  • Everything else. Arsenic results here are Virginia’s yearly averages as CDC publishes them, from 2021 on, with EPA’s national file for 2012 to 2019. Fluoride, nitrate and chromium (total) come from EPA’s file alone, which ends in 2019. Ncsa - Schuyler’s own annual report, which it must send you every year, has newer results for those and the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; CDC’s yearly averages for Virginia cover 2021 to 2023; EPA’s compliance samples are from Aug. 23, 2012 to May 22, 2019.

Testing your own tap

Ncsa - Schuyler’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab Virginia certifies.

The 3 labs Virginia certifies closest to the area Ncsa - Schuyler serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

  • Aqua-Air Lab Inc.

    Charlottesville, VA · about 15 miles

    Certified for bacteria

    (434) 295-1716

  • Augusta County Service Authority Fishersville Regional Laboratory

    Staunton, VA · about 32 miles

    Certified for bacteria

    (540) 245-5150

  • VDACS RAHL Lynchburg

    Lynchburg, VA · about 36 miles

    Certified for bacteria

Virginia Household Water Quality Program, Virginia Cooperative Extension: Drinking water clinics in about 70 counties a year, run through local Extension offices: pick up a kit, collect the sample on the set day, and drop it off locally. Each kit tests well, spring or cistern water for 28 things, including bacteria, nitrate, lead and arsenic. $70 a kit, with funding to help if you need it. Virginia Household Water Quality Program.

All 145 certified labs for Virginia

Sources