Skip to content
TapBuff

South Weber Water System

EPA’s and Utah’s records have results for 37 contaminants in its water; 6 were found.

Serves 8,125 people · Surface water bought from another system · South Weber City, UT

Serves
8,125 people
Connections
2,483
Water source
Surface water bought from another system
Based in
South Weber City, UT
County
Davis
Owner
Local government
The ZIP code it serves

84405

The short answer

None of the results here is above a limit in force today. That covers PFAS and lithium; nitrate, arsenic and other regulated chemicals; and lead and copper, not everything. 1 health-based violation since 2016, resolved in EPA’s file.

Filters for lead and arsenic, if you want them lower⁠The violation⁠Got a notice? What it means⁠

What was found

Where these results come from, and when

PFAS and lithium: EPA UCMR 5, samples taken from Feb. 21 to Nov. 19, 2024.

Lead and copper: EPA SDWIS monitoring periods ending 2002 to 2026.

Nitrate, arsenic, fluoride and chromium (total): Utah’s own results, samples taken from Aug. 19, 2020 to March 11, 2026, with EPA’s 2012 to 2019 file for earlier years.

Total trihalomethanes (TTHM) and haloacetic acids (HAA5): EPA’s compliance monitoring file, samples taken from Feb. 6, 2014 to Nov. 18, 2019. Newer results are in the utility’s annual water quality report.

What the lines mean
Legal limit (MCL):
Enforceable. The most a utility may deliver.
Action level:
Triggers action. If more than 10% of homes sampled are above it, the utility must act.
90th percentile:
How a lead or copper result is held against its action level: nine in ten of the homes sampled were at or below it.
Health goal (MCLG):
Not enforceable. The level with no expected risk, with a margin of safety.

PFAS: None of the six PFAS in EPA’s 2024 drinking water rule was found in this utility’s samples. None of the other 23 PFAS tested for was found either.

Below EPA’s limits, 6 results

Lead and arsenic have a health goal of zero: the level with no known or expected risk. Any amount found is above it, but the goal isn’t a limit.

Legal limit (MCL):
Enforceable. The most a utility may deliver.
Action level:
Triggers action. If more than 10% of homes sampled are above it, the utility must act.
90th percentile:
How a lead or copper result is held against its action level: nine in ten of the homes sampled were at or below it.
Total trihalomethanes (TTHM), Legal limit 80 ppb; highest yearly average 30 ppb

Highest yearly average, 2014 to 2019 · Forms or is added in treatment

Averaged by year, the highest was 30 ppb, in 2019, below EPA’s legal limit of 80 ppb. Its highest single sample was 44.1 ppb. That was also the latest year on file.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”
About total trihalomethanes (TTHM)
Haloacetic acids (HAA5), Legal limit 60 ppb; highest yearly average 13.6 ppb

Highest yearly average, 2014 to 2019 · 2019 average: 5.0 ppb · Forms or is added in treatment

Averaged by year, the highest was 13.6 ppb, in 2017, below EPA’s legal limit of 60 ppb. Its highest single sample was 28.7 ppb. In 2019, the latest year on file, its eight samples averaged below the limit.

What handles it

No certification claim covers this compound yet.

About haloacetic acids (HAA5)
Lead, Action level 15 ppb · health goal zero; 90th percentile 2.3 ppb

90th percentile, 2024 to 2026 · Comes from pipes, often your own

In the latest period, 9 in 10 homes sampled were at or below 2.3 ppb, below EPA’s action level of 15 ppb. The action level drops to 10 ppb on Nov. 1, 2027. EPA’s health goal for lead is zero.

What handles it

About lead
Nitrate, Legal limit 10 ppm; highest 1.3 ppm

Highest sample; found in 7 of 7 · 2026, one sample: 1.2 ppm · Comes from the source

The highest sample, in 2021, was 1.3 ppm, below EPA’s legal limit of 10 ppm. In 2026, the latest year on file, its one sample was below the limit.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest sample of 1.2 ppm, in 2019.

What handles it

  • NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
  • NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”
About nitrate
Arsenic, Legal limit 10 ppb · health goal zero; highest yearly average 0.6 ppb

Highest yearly average, 2020 to 2026 · Comes from the source

Averaged by year, the highest was 0.6 ppb, in 2026, below EPA’s legal limit of 10 ppb. Its health goal is zero, so any amount found is above it; the goal isn’t a limit. That was also the latest year on file.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 0.6 ppb, in 2016.

What handles it

  • NSF/ANSI 58 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
  • NSF/ANSI 53 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
About arsenic
Fluoride, Legal limit 4.0 ppm; highest yearly average 0.2 ppm

Highest yearly average, 2020 to 2026 · 2026: not found · Forms or is added in treatment

Averaged by year, the highest was 0.2 ppm, in 2024, below EPA’s legal limit of 4.0 ppm. In 2026, the latest year on file, it wasn’t found in its one sample.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 0.2 ppm, in 2016.

What handles it

About fluoride
Utilities above EPA’s PFAS limits, state by state⁠
31 compounds tested and not foundIncluding all six PFAS in EPA’s 2024 rule. Below the reporting level in every sample. Not found is not the same as zero.

From routine monitoring

  • Chromium (total)

PFAS and lithium, from EPA’s UCMR 5 sampling

  • 11Cl-PF3OUdS
  • 4:2 FTS
  • 6:2 FTS
  • 8:2 FTS
  • 9Cl-PF3ONS
  • ADONA
  • HFPO-DA (GenX)
  • Lithium
  • NEtFOSAA
  • NFDHA
  • NMeFOSAA
  • PFBA
  • PFBS
  • PFDA
  • PFDoA
  • PFEESA
  • PFHpA
  • PFHpS
  • PFHxA
  • PFHxS
  • PFMBA
  • PFMPA
  • PFNA
  • PFOA
  • PFOS
  • PFPeA
  • PFPeS
  • PFTA
  • PFTrDA
  • PFUnA

Violations since 2016

1 health-based violation since 2016 for the Groundwater Rule. It began April 7, 2018.

Resolved:
EPA’s file records a resolving action. The utility came back into compliance, the rule no longer applied, or no further action was needed.
No fix on record:
It records none. EPA’s own word for these is archived, addressed or unaddressed, shown beside each (EPA’s definitions, updated Oct. 9, 2026).

EPA’s file runs to 2026 Q3, so a notice your utility sent since then may not be here yet.

Got a notice about one? What it means and what to do⁠
Health-based violations, newest first
Contaminant or ruleWhat happenedPeriod, and what was measuredStatus
Groundwater RuleA significant problem found in a state inspection was not fixed on time.EPA: Failure To Address DeficiencyApril 7, 2018Resolved

Health-based violations only. 8 monitoring or reporting violations not shown.

Skip past the filters

What handles it

A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box.

  • NSF/ANSI 53

    Claims: Lead Reduction, Arsenic (Pentavalent)<=50 ppb Reduction

    For: Lead, Arsenic

    Other claims that cover it: Arsenic (III) (50 ppb influent level)

  • NSF/ANSI 58

    Claims: Lead Reduction, Arsenic (Pentavalent)<=50 ppb Reduction

    For: Lead, Arsenic

    Other claims that cover it: Arsenic (Pentavalent)<=300 ppb Reduction; Arsenic (V) (300 ppb influent level)

At the tap, or for the whole house?

These come with the water itself, so a whole-house system certified for the same claims treats every tap and shower. A filter at the tap treats drinking water for much less. How whole-house systems compare.

Filters with those claims on a certifier’s listing

Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money

2 more filters
Compare five-year costs

Every filter for these, those that cover both first⁠

The best water filters for lead, ranked⁠

The best reverse osmosis systems, ranked⁠

Disinfectant

South Weber Water System reported disinfecting with chlorine, not chloramine, at all 2 of its sampling points, in its 2024 sampling for EPA. It also reported ozone, permanganate and ultraviolet light.

What that means

Chlorine leaves water that sits out for a few days, CDC says. A filter certified for it carries a chlorine claim under NSF/ANSI 42; a shower filter, a free chlorine claim under NSF/ANSI 177. This utility buys its water from another system, so what it reported may leave out treatment done before the water reaches it. This is what the utility reported for that sampling. Its annual water quality report says what it uses now.

What this report can’t tell you

  • Everything else. Nitrate, arsenic, fluoride and chromium (total) results here are Utah’s own from 2020 on, with EPA’s national file for 2012 to 2019. Total trihalomethanes (TTHM) and haloacetic acids (HAA5) come from EPA’s file alone, which ends in 2019. South Weber Water System’s own annual report, which it must send you every year, has newer results for those and the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 samples are from Feb. 21 to Nov. 19, 2024; Utah’s results run from Aug. 19, 2020 to March 11, 2026; EPA’s compliance samples are from Feb. 6, 2014 to Nov. 18, 2019.

Testing your own tap

South Weber Water System’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab Utah certifies.

What to test for at your tap

  • Lead and copper. Both come mostly from a building’s own service line, solder and faucets, so a utility’s numbers can’t tell you yours. South Weber Water System’s latest lead sampling in EPA’s records, 2024 to 2026, had a 90th percentile of 2.3 ppb: 9 in 10 of the homes it sampled were at or below that. The action level is 15 ppb, dropping to 10 ppb in November 2027, and EPA’s health goal for lead is zero. About lead.
The 3 labs Utah certifies closest to the area South Weber Water System serves, or a kit by mail

The 3 labs Utah certifies closest to the area South Weber Water System serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

  • Weber Basin Water Quality Laboratory

    Layton, UT · about 4 miles

    Certified for bacteria, nitrate, lead and copper, metals, minerals and other inorganics, disinfection byproducts

    (801) 771-1677

  • Davis County Environmental Health Laboratory

    Clearfield, UT · about 4 miles

    Certified for bacteria, minerals and other inorganics

    (801) 525-5115

  • North Davis Sewer District Laboratory

    Syracuse, UT · about 9 miles

    Certified for bacteria

    (801) 825-0712

All 60 certified labs for Utah⁠

Or test by mail

Tap Score sells lab tests as kits you fill at your tap and mail back. The sample goes to Tap Score’s lab, not one near you, so check that Utah certifies it for the test you want.

  • Tap Score

    Return shipping included.

    Tap Score says each kit ships to “an accredited laboratory” but doesn’t name it, so TapBuff can’t check it against Utah’s list.

Prices from Tap Score’s own store on Oct. 22, 2026.

What to do now

Sources

PWSID UTAH06010. Rebuilt from EPA data on Oct. 25, 2026.