Skip to content
TapBuff

Moroni City

What EPA’s and Utah’s records show in this utility’s water: nitrate, arsenic and other regulated chemicals; lead and copper; and violations since 2016, with the certification that handles each result.

Serves
1,600 people
Connections
571
Water source
Groundwater
Based in
Morni, UT
County
Sanpete
Owner
Local government
Hardness
Hard
The ZIP code it serves

84646

The short answer

4 results are above the health goal. The worst: Nitrate, above the health goal. No health-based violations on file since 2016.

What handles it

What was found

Lead and copper: EPA SDWIS monitoring periods ending 2004 to 2024.

Nitrate, arsenic, uranium, fluoride and chromium (total): Utah’s own results, samples taken from Jan. 7, 2020 to Jan. 22, 2026, with EPA’s 2012 to 2019 file for earlier years.

Total trihalomethanes (TTHM) and haloacetic acids (HAA5): EPA’s compliance monitoring file, samples taken from Sept. 13, 2016 to Sept. 24, 2019. Newer results are in the utility’s annual water quality report.

Above the health goal4

Nitrate

Comes from the source

Above the health goal

11.5ppm

Highest sample; found in 153 of 155

2026, one sample: 0.87 ppm

In 2020, two samples were above EPA’s legal limit of 10 ppm, the highest 11.5 ppm. Every one came back under the limit on the next sample at the same point. 10 ppm is also EPA’s health goal. In 2026, the latest year on file, its one sample was 0.87 ppm. EPA recorded no violation for nitrate at this utility since 2020. Earlier, from 2012 to 2019, EPA’s file shows a highest sample of 11.6 ppm, in 2019.

What handles it

  • NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
  • NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”

Arsenic

Comes from the source

Above the health goal

5.3ppb

Highest yearly average, 2022 to 2026

Averaged by year, the highest was 5.3 ppb, in 2026: below EPA’s legal limit of 10 ppb, but above its health goal of zero. That was also the latest year on file. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 5.3 ppb, in 2019.

What handles it

  • NSF/ANSI 58 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
  • NSF/ANSI 53 look for “Arsenic (Pentavalent)<=50 ppb Reduction”

Uranium

Comes from the source

Above the health goal

11.8ppb

Highest yearly average, 2022

Averaged by year, the highest was 11.8 ppb, in 2022: below EPA’s legal limit of 30 ppb, but above its health goal of zero. That is the only year on file. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 16.5 ppb, in 2019.

What handles it

Lead

Comes from pipes, often your own

Above the health goal

0.6ppb

90th percentile, 2022 to 2024

In the latest period, 9 in 10 homes sampled were at or below 0.6 ppb, below EPA’s action level of 15 ppb. The action level drops to 10 ppb on Nov. 1, 2027. EPA’s health goal for lead is zero.

What handles it

Below EPA’s limits3

Total trihalomethanes (TTHM)

Forms or is added in treatment

Below EPA’s limits

33ppb

Highest yearly average, 2016 to 2019

2019, one sample: 10.9 ppb

Averaged by year, the highest was 33 ppb, in 2016, below EPA’s legal limit of 80 ppb. In 2019, the latest year on file, its one sample was 10.9 ppb.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”

Haloacetic acids (HAA5)

Forms or is added in treatment

Below EPA’s limits

7.8ppb

Highest yearly average, 2016 to 2019

2019, one sample: 5.8 ppb

Averaged by year, the highest was 7.8 ppb, in 2016, below EPA’s legal limit of 60 ppb. In 2019, the latest year on file, its one sample was 5.8 ppb.

What handles it

No certification claim covers this compound yet.

Fluoride

Forms or is added in treatment

Below EPA’s limits

0.2ppm

Highest yearly average, 2022 to 2026

2026, one sample: 0.14 ppm

Averaged by year, the highest was 0.2 ppm, in 2022, below EPA’s legal limit of 4.0 ppm. Its highest single sample was 0.21 ppm. In 2026, the latest year on file, its one sample was 0.14 ppm. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 0.23 ppm, in 2019.

What handles it

One compound tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
  • Chromium (total)

What handles it

A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box. Wording varies a little: NSF writes “Lead Reduction,” WQA just “Lead.”

  • NSF/ANSI 53

    Claims: Nitrate/Nitrite (30 ppm challenge), Arsenic (Pentavalent)<=50 ppb Reduction, Lead Reduction

    For: Nitrate, Arsenic, Lead

    Other certifiers’ wording: Arsenic (III) (50 ppb influent level)

  • NSF/ANSI 58

    Claims: Nitrate/Nitrite Reduction, Arsenic (Pentavalent)<=50 ppb Reduction, Uranium, Lead Reduction

    For: Nitrate, Arsenic, Uranium, Lead

    Other certifiers’ wording: Nitrate; Arsenic (Pentavalent)<=300 ppb Reduction; Arsenic (V) (300 ppb influent level)

At the tap, or for the whole house?

Lead and copper usually come from pipes and fixtures inside or near your home. A whole-house system sits where water enters, so it cannot catch what your own plumbing adds after it. For those, the filter that counts is the one at the tap. How whole-house systems compare.

Filters with those claims on a certifier’s listing

Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money

Compare five-year costs

The best reverse osmosis systems, ranked

The best water filters for lead, ranked

Hardness

Hard, 155 mg/L (9.1 grains per gallon), at its one sampling point, in 2022.

Hardness is calcium and magnesium. EPA sets no limit for it: it shows up as scale on fixtures and in water heaters, and as soap that won’t lather. USGS calls water above 60 mg/L moderately hard, above 120 hard and above 180 very hard.

Violations since 2016

No health-based violations on file with EPA since 2016. There are 64 monitoring or reporting violations: a sample missed, late or not reported.

What this report can’t tell you

  • Everything else. Nitrate, arsenic, uranium, fluoride and chromium (total) results here are Utah’s own from 2020 on, with EPA’s national file for 2012 to 2019. Total trihalomethanes (TTHM) and haloacetic acids (HAA5) come from EPA’s file alone, which ends in 2019. Moroni City’s own annual report, which it must send you every year, has newer results for those and the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; Utah’s results run from Jan. 7, 2020 to Jan. 22, 2026; EPA’s compliance samples are from Sept. 13, 2016 to Sept. 24, 2019.

Testing your own tap

Moroni City’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab Utah certifies.

The 3 labs Utah certifies closest to the area Moroni City serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

  • SE Utah District Health Department Laboratory

    Price, UT · about 43 miles

    Certified for bacteria

    (435) 637-3671

  • Provo Water Resources Laboratory

    Provo, UT · about 46 miles

    Certified for bacteria

    (801) 852-6796

  • Central Utah Public Health Laboratory

    Richfield, UT · about 59 miles

    Certified for bacteria, nitrate

    (435) 896-5451

All 60 certified labs for Utah

Sources

PWSID UTAH20013. Rebuilt from EPA data on Oct. 18, 2026.