Travis County MUD 4
EPA’s and Texas’s records have results for 8 contaminants in its water; 5 were found.
In the name, MUD means municipal utility district.
Serves 6,816 people · Surface water · Austin, TX
- Serves
- 6,816 people
- Connections
- 3,249
- Water source
- Surface water
- Based in
- Austin, TX
- County
- Travis
- Owner
- Local government
The ZIP code it serves
The short answer
None of the results here is above a limit in force today. That covers nitrate, arsenic and other regulated chemicals, plus lead and copper, not everything. No health-based violations on file since 2016.
What was found
Where these results come from, and when
Total trihalomethanes (TTHM), haloacetic acids (HAA5), fluoride, uranium, nitrate, arsenic and chromium (total): Texas’s own results, samples taken from March 3, 2020 to July 1, 2026, with EPA’s 2012 to 2019 file for earlier years.
What the lines mean
- Legal limit (MCL):
- Enforceable. The most a utility may deliver.
- Health goal (MCLG):
- Not enforceable. The level with no expected risk, with a margin of safety.
Below EPA’s limits, 5 results
Uranium has a health goal of zero: the level with no known or expected risk. Any amount found is above it, but the goal isn’t a limit.
- Legal limit (MCL):
- Enforceable. The most a utility may deliver.
Total trihalomethanes (TTHM), Legal limit 80 ppb; highest yearly average 33.3 ppb
Highest yearly average, 2020 to 2026 · Forms or is added in treatment
Averaged by year, the highest was 33.3 ppb, in 2026, below EPA’s legal limit of 80 ppb. Its highest single sample was 80.6 ppb. That was also the latest year on file. EPA recorded no violation for total trihalomethanes (TTHM) at this utility since 2020.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest yearly average of 78.5 ppb, in 2015.
What handles it
- NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
- NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”
Haloacetic acids (HAA5), Legal limit 60 ppb; highest yearly average 17.4 ppb
Highest yearly average, 2020 to 2026 · Forms or is added in treatment
Averaged by year, the highest was 17.4 ppb, in 2026, below EPA’s legal limit of 60 ppb. Its highest single sample was 32.5 ppb. That was also the latest year on file.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest yearly average of 45.9 ppb, in 2015.
What handles it
No certification claim covers this compound yet.
Fluoride, Legal limit 4.0 ppm; highest yearly average 0.21 ppm
Highest yearly average, 2020 to 2026 · 2026: not found · Forms or is added in treatment
Averaged by year, the highest was 0.21 ppm, in 2021, below EPA’s legal limit of 4.0 ppm. Its highest single sample was 0.23 ppm. In 2026, the latest year on file, it wasn’t found in any of its two samples.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest yearly average of 0.25 ppm, in 2012.
What handles it
- NSF/ANSI 58 look for “Fluoride Reduction”
- NSF/ANSI 53 look for “Fluoride”
Uranium, Legal limit 30 ppb · health goal zero; highest yearly average 1.2 ppb
Highest yearly average, 2021 to 2024 · 2024: not found · Comes from the source
Averaged by year, the highest was 1.2 ppb, in 2021, below EPA’s legal limit of 30 ppb. Its health goal is zero, so any amount found is above it; the goal isn’t a limit. In 2024, the latest year on file, it wasn’t found in its one sample.
What handles it
- NSF/ANSI 58 look for “Uranium”
Nitrate, Legal limit 10 ppm; highest 0.38 ppm
Highest sample; found in 12 of 14 · 2026 average: 0.19 ppm · Comes from the source
The highest sample, in 2026, was 0.38 ppm, below EPA’s legal limit of 10 ppm. That was also the latest year on file, and its two samples averaged below the limit.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest sample of 0.95 ppm, in 2016.
What handles it
- NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
- NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”
3 compounds tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
- Arsenic
- Chromium (total)
- Lead
Violations since 2016
No health-based violations on file with EPA since 2016. There are 4 monitoring or reporting violations: a sample missed, late or not reported. EPA’s file runs to 2026 Q3, so a notice your utility sent since then may not be here yet.
What handles it
A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box.
- NSF/ANSI 58
Claim: Uranium
For: Uranium
At the tap, or for the whole house?
These come with the water itself, so a whole-house system certified for the same claims treats every tap and shower. A filter at the tap treats drinking water for much less. How whole-house systems compare.
Filters with those claims on a certifier’s listing
None of the filters TapBuff has checked so far carry these claims. Search the certifier listings for the claim above.
Compare five-year costsWhat this report can’t tell you
Everything else. Total trihalomethanes (TTHM), haloacetic acids (HAA5), fluoride, uranium, nitrate, arsenic and chromium (total) results here are Texas’s own from 2020 on, with EPA’s national file for 2012 to 2019. Travis County MUD 4’s own annual report, which it must send you every year, has the contaminants this page does not show.
Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.
What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.
Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; Texas’s results run from March 3, 2020 to July 1, 2026.
Testing your own tap
What to test for at your tap
- Lead and copper. Both come mostly from a building’s own service line, solder and faucets, so a utility’s numbers can’t tell you yours. Travis County MUD 4’s latest lead sampling in EPA’s records, 2025, had a 90th percentile of 0 ppb across the homes it sampled. The action level is 15 ppb, dropping to 10 ppb in November 2027, and EPA’s health goal for lead is zero. About lead.
The 3 labs Texas certifies closest to the area Travis County MUD 4 serves, or a kit by mail
The 3 labs Texas certifies closest to the area Travis County MUD 4 serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.
Texas Department of State Health Services Laboratory Services Section
Austin, TX · about 9 miles
Certified for bacteria, lead and copper
Aqua-Tech Laboratories, Inc.
Austin, TX · about 11 miles
Certified for bacteria, lead and copper
Integrity Testing, Inc.
Austin, TX · about 11 miles
Certified for lead and copper
Or test by mail
Tap Score sells lab tests as kits you fill at your tap and mail back. The sample goes to Tap Score’s lab, not one near you, so check that Texas certifies it for the test you want.
Tap Score
- Lead and Copper Water Test, with a pH test strip: $55
- Essential City Water Test, 25 metals, 4 minerals, nitrate, fluoride, hardness and pH: $189
Return shipping included.
Tap Score says each kit ships to “an accredited laboratory” but doesn’t name it, so TapBuff can’t check it against Texas’s list.
Prices from Tap Score’s own store on Oct. 22, 2026.
What to do now
- Nothing here is above an EPA limit or health benchmarkIn EPA’s and Texas’s records for this utility. They don’t cover everything, which is why the next step matters.Every contaminant TapBuff tracks
- Get the utility’s own reportTravis County MUD 4 must send you a water quality report every year. It covers contaminants this page does not show.How to read it
- Test your own tap for leadIts latest lead sampling found none at the 90th percentile, but your own service line, solder and fixtures decide the lead at your faucet.Lead in your water: what to do
Sources
- EPA UCMR 5 occurrence data, file of Oct. 15, 2026
- EPA SDWA bulk download (SDWIS federal data), 2026 Q3
- Texas Commission on Environmental Quality, Texas Drinking Water Viewer, results from Jan. 7, 2020 to Oct. 6, 2026, read Oct. 16, 2026
- EPA Six-Year Review 4 compliance monitoring data, 2012 to 2019, file of Feb. 5, 2024
- Certified labs: TCEQ, drinking water laboratories approved for public water system samples, read Oct. 10, 2026; distances from the Census 2020 ZIP code tabulation area gazetteer
- Limits and goals: each contaminant’s page, with its EPA source.
- How this page is built: methodology.
PWSID TX2270325. Rebuilt from EPA data on Oct. 25, 2026.