Skip to content
TapBuff

Straightway Training Center

What EPA’s and Texas’s records show in this utility’s water: nitrate, arsenic and other regulated chemicals; lead and copper; and violations since 2016, with the certification that handles each result.

Serves
50 people
Connections
8
Water source
Groundwater
Based in
Hungerford, TX
County
Wharton
Owner
Private
The ZIP code it serves

77448

The short answer

3 results are above the health goal. The worst: Arsenic, above the health goal. 1 health-based violation since 2016.

What handles it

What was found

Lead and copper: EPA SDWIS monitoring periods ending 1996 to 2026.

Arsenic, fluoride, nitrate, chromium (total), haloacetic acids (HAA5) and total trihalomethanes (TTHM): Texas’s own results, samples taken from Sept. 30, 2020 to July 30, 2025, with EPA’s 2012 to 2019 file for earlier years.

Uranium: EPA’s compliance monitoring file, samples taken from April 30, 2018 to April 30, 2018. Newer results are in the utility’s annual water quality report.

Above the health goal3

Arsenic

Comes from the source

Above the health goal

2.1ppb

Highest yearly average, 2022 to 2025

Averaged by year, the highest was 2.1 ppb, in 2025: below EPA’s legal limit of 10 ppb, but above its health goal of zero. That was also the latest year on file. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 3.1 ppb, in 2012.

What handles it

  • NSF/ANSI 58 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
  • NSF/ANSI 53 look for “Arsenic (Pentavalent)<=50 ppb Reduction”

Uranium

Comes from the source

Above the health goal

1.9ppb

Highest yearly average, 2018

Averaged by year, the highest was 1.9 ppb, in 2018: below EPA’s legal limit of 30 ppb, but above its health goal of zero. That is the only year on file.

What handles it

Lead

Comes from pipes, often your own

Above the health goal

0.42ppb

90th percentile, 2026

In the latest period, 9 in 10 homes sampled were at or below 0.42 ppb, below EPA’s action level of 15 ppb. The action level drops to 10 ppb on Nov. 1, 2027. EPA’s health goal for lead is zero.

What handles it

Below EPA’s limits2

Fluoride

Forms or is added in treatment

Below EPA’s limits

0.29ppm

Highest yearly average, 2022 to 2025

2025: not found

Averaged by year, the highest was 0.29 ppm, in 2022, below EPA’s legal limit of 4.0 ppm. In 2025, the latest year on file, it wasn’t found in its one sample. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 0.33 ppm, in 2016.

What handles it

Nitrate

Comes from the source

Below EPA’s limits

0.23ppm

Highest sample; found in 5 of 6

2025: not found

The highest sample, in 2024, was 0.23 ppm, below EPA’s legal limit of 10 ppm. In 2025, the latest year on file, it wasn’t found in its one sample. Earlier, from 2012 to 2019, EPA’s file shows a highest sample of 0.21 ppm, in 2013.

What handles it

  • NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
  • NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”
3 compounds tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
  • Chromium (total)
  • Haloacetic acids (HAA5)
  • Total trihalomethanes (TTHM)

What handles it

A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box. Wording varies a little: NSF writes “Lead Reduction,” WQA just “Lead.”

  • NSF/ANSI 53

    Claims: Arsenic (Pentavalent)<=50 ppb Reduction, Lead Reduction

    For: Arsenic, Lead

    Other certifiers’ wording: Arsenic (III) (50 ppb influent level)

  • NSF/ANSI 58

    Claims: Arsenic (Pentavalent)<=50 ppb Reduction, Uranium, Lead Reduction

    For: Arsenic, Uranium, Lead

    Other certifiers’ wording: Arsenic (Pentavalent)<=300 ppb Reduction; Arsenic (V) (300 ppb influent level)

At the tap, or for the whole house?

Lead and copper usually come from pipes and fixtures inside or near your home. A whole-house system sits where water enters, so it cannot catch what your own plumbing adds after it. For those, the filter that counts is the one at the tap. How whole-house systems compare.

Filters with those claims on a certifier’s listing

Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money

Compare five-year costs

The best reverse osmosis systems, ranked

The best water filters for lead, ranked

Violations since 2016

Contaminant or ruleTypePeriodMeasuredStatus
Lead and Copper Rule RevisionsThe required inventory of lead service lines was not completed or submitted on time.EPA: LSL InventoryOct. 17, 2024—Resolved
Health-based violations only. Resolved and archived mean the utility returned to compliance or the state closed the record. 53 monitoring or reporting violations not shown.

What this report can’t tell you

  • Everything else. Arsenic, fluoride, nitrate, chromium (total), haloacetic acids (HAA5) and total trihalomethanes (TTHM) results here are Texas’s own from 2020 on, with EPA’s national file for 2012 to 2019. Uranium comes from EPA’s file alone, which ends in 2019. Straightway Training Center’s own annual report, which it must send you every year, has newer results for those and the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; Texas’s results run from Sept. 30, 2020 to July 30, 2025; EPA’s compliance samples are from April 30, 2018 to April 30, 2018.

Testing your own tap

Straightway Training Center’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab Texas certifies.

The 3 labs Texas certifies closest to the area Straightway Training Center serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

  • Eurofins Xenco, LLC -Houston

    Stafford, TX · about 34 miles

    Certified for lead and copper

    (281) 240-4200

  • ALS Laboratory Group, Environmental Services Division – Houston, Texas

    Houston, TX · about 35 miles

    Certified for lead and copper

    (281) 530-5656

  • Envirodyne Laboratories, Inc.

    Houston, TX · about 35 miles

    Certified for bacteria, lead and copper

    (281) 568-7880

Texas Well Owner Network, Texas A&M AgriLife Extension: Well Informed screening events, where well owners bring in water samples to be screened for common contaminants, followed by an hour-long session explaining the results. Upcoming events are on the network's calendar. Trainings, Texas Well Owner Network.

All 80 certified labs for Texas

Sources