Skip to content
TapBuff

South Rusk County WSC

What EPA’s and Texas’s records show in this utility’s water: nitrate, arsenic and other regulated chemicals; lead and copper; and violations since 2016, with the certification that handles each result.

Serves
1,947 people
Connections
649
Water source
Groundwater
Based in
Laneville, TX
County
Rusk
Owner
Local government
The 5 ZIP codes it serves

75654, 75667, 75681, 75760, 75784

The short answer

1 result is above EPA’s legal limit, and 1 more is above the health goal. The worst: Total trihalomethanes (TTHM), above the legal limit. 6 health-based violations since 2016.

What handles it

What was found

Lead and copper: EPA SDWIS monitoring periods ending 1994 to 2025.

Total trihalomethanes (TTHM), haloacetic acids (HAA5), fluoride, chromium (total), nitrate, arsenic and uranium: Texas’s own results, samples taken from Jan. 8, 2020 to Aug. 20, 2026, with EPA’s 2012 to 2019 file for earlier years.

Above the legal limit1

Total trihalomethanes (TTHM)

Forms or is added in treatment

Above the legal limit

89.7ppb

Highest yearly average, 2020 to 2026

2026 average: 46.4 ppb

Averaged by year, the highest was 89.7 ppb, in 2021, above EPA’s legal limit of 80 ppb. Its highest single sample was 114 ppb. In 2026, the latest year on file, its six samples averaged 46.4 ppb. EPA recorded violations for total trihalomethanes (TTHM) at this utility in 2022 and 2025. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 82.6 ppb, in 2015, and EPA recorded a violation in 2017.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”

Above the health goal1

Lead

Comes from pipes, often your own

Above the health goal

0.6ppb

90th percentile, 2023 to 2025

In the latest period, 9 in 10 homes sampled were at or below 0.6 ppb, below EPA’s action level of 15 ppb. The action level drops to 10 ppb on Nov. 1, 2027. EPA’s health goal for lead is zero.

What handles it

Below EPA’s limits4

Haloacetic acids (HAA5)

Forms or is added in treatment

Below EPA’s limits

34.8ppb

Highest yearly average, 2020 to 2026

2026 average: 26 ppb

Averaged by year, the highest was 34.8 ppb, in 2021, below EPA’s legal limit of 60 ppb. Its highest single sample was 55.5 ppb. In 2026, the latest year on file, its six samples averaged 26 ppb. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 37.3 ppb, in 2015.

What handles it

No certification claim covers this compound yet.

Fluoride

Forms or is added in treatment

Below EPA’s limits

1.5ppm

Highest yearly average, 2021 to 2024

2024, one sample: 1.4 ppm

Averaged by year, the highest was 1.5 ppm, in 2021, below EPA’s legal limit of 4.0 ppm. In 2024, the latest year on file, its one sample was 1.4 ppm. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 1.5 ppm, in 2012.

What handles it

Chromium (total)

Comes from the source

Below EPA’s limits

10ppb

Highest yearly average, 2021 to 2024

Averaged by year, the highest was 10 ppb, in 2024, below EPA’s legal limit of 100 ppb. That was also the latest year on file.

What handles it

Nitrate

Comes from the source

Below EPA’s limits

0.04ppm

Highest sample; found in 6 of 6

2025, one sample: 0.033 ppm

The highest sample, in 2022, was 0.04 ppm, below EPA’s legal limit of 10 ppm. In 2025, the latest year on file, its one sample was 0.033 ppm. Earlier, from 2012 to 2019, EPA’s file shows a highest sample of 0.083 ppm, in 2013.

What handles it

  • NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
  • NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”
2 compounds tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
  • Arsenic
  • Uranium

What handles it

A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box. Wording varies a little: NSF writes “Lead Reduction,” WQA just “Lead.”

  • NSF/ANSI 53

    Claims: Trihalomethanes (TTHM) Reduction, Lead Reduction

    For: Total trihalomethanes (TTHM), Lead

    Other certifiers’ wording: VOC Reduction

  • NSF/ANSI 58

    Claims: Trihalomethanes (TTHM) Reduction, Lead Reduction

    For: Total trihalomethanes (TTHM), Lead

At the tap, or for the whole house?

Lead and copper usually come from pipes and fixtures inside or near your home. A whole-house system sits where water enters, so it cannot catch what your own plumbing adds after it. For those, the filter that counts is the one at the tap. How whole-house systems compare.

Filters with those claims on a certifier’s listing

Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money

Compare five-year costs

The best water filters for lead, ranked

Violations since 2016

Contaminant or ruleTypePeriodMeasuredStatus
TTHMThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageApril 1, 2025 to June 30, 20250.089 MG/LResolved
TTHMThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJan. 1, 2025 to March 31, 20250.082 MG/LResolved
Lead and Copper Rule RevisionsThe required inventory of lead service lines was not completed or submitted on time.EPA: LSL InventoryOct. 17, 2024—Resolved
TTHMThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageApril 1, 2022 to June 30, 20220.085 MG/LResolved
TTHMThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJuly 1, 2017 to Sept. 30, 20170.087 MG/LResolved
TTHMThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageApril 1, 2017 to June 30, 20170.088 MG/LResolved
Health-based violations only. Resolved and archived mean the utility returned to compliance or the state closed the record. 7 monitoring or reporting violations not shown.

What this report can’t tell you

  • Everything else. Total trihalomethanes (TTHM), haloacetic acids (HAA5), fluoride, chromium (total), nitrate, arsenic and uranium results here are Texas’s own from 2020 on, with EPA’s national file for 2012 to 2019. South Rusk County WSC’s own annual report, which it must send you every year, has the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; Texas’s results run from Jan. 8, 2020 to Aug. 20, 2026.

Testing your own tap

South Rusk County WSC’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab Texas certifies.

The 3 labs Texas certifies closest to the area South Rusk County WSC serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

  • Southern Petroleum Laboratories (SPL), Inc. (FKA Ana-Lab Corporation)

    Kilgore, TX · about 31 miles

    Certified for bacteria, lead and copper

    (903) 984-0551

  • Eastex Environmental Lab, Inc.-Nacogdoches

    Nacogdoches, TX · about 33 miles

    Certified for bacteria

    (936) 569-8879

  • Analytical Environmental Labs

    Tyler, TX · about 35 miles

    Certified for bacteria

    (903) 509-8700

Texas Well Owner Network, Texas A&M AgriLife Extension: Well Informed screening events, where well owners bring in water samples to be screened for common contaminants, followed by an hour-long session explaining the results. Upcoming events are on the network's calendar. Trainings, Texas Well Owner Network.

All 80 certified labs for Texas

Sources

PWSID TX2010039. Rebuilt from EPA data on Oct. 18, 2026.