What EPA’s and Texas’s records show in this utility’s water: nitrate, arsenic and other regulated chemicals; lead and copper; and violations since 2016, with the certification that handles each result.

Serves
777 people
Connections
259
Water source
Groundwater
Based in
Skidmore, TX
County
Bee
Owner
Local government
The ZIP code it serves

78389

The short answer

1 result is above the health goal. The worst: Uranium, above the health goal. 22 health-based violations since 2016.

What handles it

What was found

Uranium, haloacetic acids (HAA5), fluoride, nitrate, total trihalomethanes (TTHM), arsenic and chromium (total): Texas’s own results, samples taken from Jan. 14, 2020 to Aug. 6, 2026, with EPA’s 2012 to 2019 file for earlier years.

Above the health goal1

Uranium

Comes from the source

Above the health goal

22ppb

Highest yearly average, 2020 to 2026

2026, one sample: 17.7 ppb

Averaged by year, the highest was 22 ppb, in 2024: below EPA’s legal limit of 30 ppb, but above its health goal of zero. Its highest single sample was 25.7 ppb. In 2026, the latest year on file, its one sample was 17.7 ppb. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 21.3 ppb, in 2016.

What handles it

Below EPA’s limits4

Haloacetic acids (HAA5)

Forms or is added in treatment

Below EPA’s limits

21.9ppb

Highest yearly average, 2020 to 2026

2026: not found

Averaged by year, the highest was 21.9 ppb, in 2025, below EPA’s legal limit of 60 ppb. In 2026, the latest year on file, it wasn’t found in its one sample. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 4.3 ppb, in 2018.

What handles it

No certification claim covers this compound yet.

Fluoride

Forms or is added in treatment

Below EPA’s limits

0.49ppm

Highest yearly average, 2021 to 2024

Averaged by year, the highest was 0.49 ppm, in 2024, below EPA’s legal limit of 4.0 ppm. That was also the latest year on file. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 0.54 ppm, in 2018.

What handles it

Nitrate

Comes from the source

Below EPA’s limits

0.9ppm

Highest sample; found in 7 of 7

2026, one sample: 0.53 ppm

The highest sample, in 2020, was 0.9 ppm, below EPA’s legal limit of 10 ppm. In 2026, the latest year on file, its one sample was 0.53 ppm. Earlier, from 2012 to 2019, EPA’s file shows a highest sample of 0.88 ppm, in 2016.

What handles it

  • NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
  • NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”

Total trihalomethanes (TTHM)

Forms or is added in treatment

Below EPA’s limits

2.0ppb

Highest yearly average, 2020 to 2026

2026: not found

Averaged by year, the highest was 2.0 ppb, in 2021, below EPA’s legal limit of 80 ppb. In 2026, the latest year on file, it wasn’t found in its one sample.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”
3 compounds tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
  • Arsenic
  • Chromium (total)
  • Lead

What handles it

A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box. Wording varies a little: NSF writes “Lead Reduction,” WQA just “Lead.”

At the tap, or for the whole house?

These come with the water itself, so a whole-house system certified for the same claims treats every tap and shower. A filter at the tap treats drinking water for much less. How whole-house systems compare.

Filters with those claims on a certifier’s listing

None of the filters TapBuff has checked so far carry these claims. Search the certifier listings for the claim above.

Compare five-year costs

Violations since 2016

Contaminant or ruleTypePeriodMeasuredStatus
Gross alpha radiation (excluding radon and uranium)The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJan. 1, 2026 to March 31, 202617 PCI/LArchived
Gross alpha radiation (excluding radon and uranium)The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageOct. 1, 2025 to Dec. 31, 202516 PCI/LArchived
Gross alpha radiation (excluding radon and uranium)The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageApril 1, 2024 to June 30, 202417 PCI/LResolved
Gross alpha radiation (excluding radon and uranium)The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageOct. 1, 2023 to Dec. 31, 202316 PCI/LResolved
Gross alpha radiation (excluding radon and uranium)The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageOct. 1, 2022 to Dec. 31, 202216 PCI/LResolved
Gross alpha radiation (excluding radon and uranium)The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageApril 1, 2022 to June 30, 202218 PCI/LResolved
Gross alpha radiation (excluding radon and uranium)The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJan. 1, 2022 to March 31, 202217 PCI/LResolved
Gross alpha radiation (excluding radon and uranium)The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJuly 1, 2021 to Sept. 30, 202118 PCI/LResolved
Gross alpha radiation (excluding radon and uranium)The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageApril 1, 2021 to June 30, 202116 PCI/LResolved
Gross alpha radiation (excluding radon and uranium)The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJan. 1, 2021 to March 31, 202118 PCI/LResolved
Gross alpha radiation (excluding radon and uranium)The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageOct. 1, 2020 to Dec. 31, 202018 PCI/LResolved
Gross alpha radiation (excluding radon and uranium)The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJuly 1, 2020 to Sept. 30, 202018 PCI/LResolved
Gross alpha radiation (excluding radon and uranium)The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageApril 1, 2020 to June 30, 202018 PCI/LResolved
Gross alpha radiation (excluding radon and uranium)The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJan. 1, 2020 to March 31, 202016 PCI/LResolved
Gross alpha radiation (excluding radon and uranium)The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageOct. 1, 2018 to Dec. 31, 201820 PCI/LResolved
Gross alpha radiation (excluding radon and uranium)The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJuly 1, 2018 to Sept. 30, 201822 PCI/LResolved
Gross alpha radiation (excluding radon and uranium)The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageApril 1, 2018 to June 30, 201820 PCI/LResolved
Gross alpha radiation (excluding radon and uranium)The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJan. 1, 2018 to March 31, 201820 PCI/LResolved
Gross alpha radiation (excluding radon and uranium)The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageOct. 1, 2017 to Dec. 31, 201719 PCI/LResolved
Gross alpha radiation (excluding radon and uranium)The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJuly 1, 2017 to Sept. 30, 201719 PCI/LResolved
Gross alpha radiation (excluding radon and uranium)The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageApril 1, 2017 to June 30, 201717 PCI/LResolved
Gross alpha radiation (excluding radon and uranium)The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJan. 1, 2017 to March 31, 201716 PCI/LResolved
Health-based violations only. Resolved and archived mean the utility returned to compliance or the state closed the record. 5 monitoring or reporting violations not shown.

What this report can’t tell you

  • Everything else. Uranium, haloacetic acids (HAA5), fluoride, nitrate, total trihalomethanes (TTHM), arsenic and chromium (total) results here are Texas’s own from 2020 on, with EPA’s national file for 2012 to 2019. Skidmore WSC’s own annual report, which it must send you every year, has the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; Texas’s results run from Jan. 14, 2020 to Aug. 6, 2026.

Testing your own tap

Skidmore WSC’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab Texas certifies.

The 3 labs Texas certifies closest to the area Skidmore WSC serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

  • Corpus Christi -Nueces County Public Health District Laboratory

    Corpus Christi, TX · about 37 miles

    Certified for bacteria

    (361) 826-7213

  • Pace Analytical Services, LLC -Dallas TX

    Victoria, TX · about 56 miles

    Certified for bacteria

    (361) 465-7989

  • Victoria County Public Health Department Water Laboratory

    Victoria, TX · about 56 miles

    Certified for bacteria

    (361) 578-6281

Texas Well Owner Network, Texas A&M AgriLife Extension: Well Informed screening events, where well owners bring in water samples to be screened for common contaminants, followed by an hour-long session explaining the results. Upcoming events are on the network's calendar. Trainings, Texas Well Owner Network.

All 80 certified labs for Texas

Sources

PWSID TX0130066. Rebuilt from EPA data on Oct. 18, 2026.