What EPA’s and Texas’s records show in this utility’s water: nitrate, arsenic and other regulated chemicals; lead and copper; and violations since 2016, with the certification that handles each result.

Serves
120 people
Connections
68
Water source
Groundwater bought from another system
Based in
Sanford, TX
County
Hutchinson
Owner
Local government
The ZIP code it serves

79078

The short answer

Nothing in EPA’s and Texas’s records for this utility is above a health goal. That covers nitrate, arsenic and other regulated chemicals, plus lead and copper, not everything. 2 health-based violations since 2016.

What was found

Lead and copper: lead at 0.32 mg/L (2026) is left out of this report: more than 20 times the action level, it looks like µg/L entered as mg/L.

Haloacetic acids (HAA5), nitrate and total trihalomethanes (TTHM): Texas’s own results, samples taken from May 7, 2020 to July 14, 2026, with EPA’s 2012 to 2019 file for earlier years.

Below EPA’s limits3

Haloacetic acids (HAA5)

Forms or is added in treatment

Below EPA’s limits

10.1ppb

Highest yearly average, 2022 to 2025

Averaged by year, the highest was 10.1 ppb, in 2025, below EPA’s legal limit of 60 ppb. That was also the latest year on file. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 2.5 ppb, in 2013.

What handles it

No certification claim covers this compound yet.

Nitrate

Comes from the source

Below EPA’s limits

1.7ppm

Highest sample; found in 7 of 7

2026, one sample: 1.6 ppm

The highest sample, in 2025, was 1.7 ppm, below EPA’s legal limit of 10 ppm. In 2026, the latest year on file, its one sample was 1.6 ppm.

What handles it

  • NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
  • NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”

Total trihalomethanes (TTHM)

Forms or is added in treatment

Below EPA’s limits

8.1ppb

Highest yearly average, 2022 to 2025

2025, one sample: 5.8 ppb

Averaged by year, the highest was 8.1 ppb, in 2022, below EPA’s legal limit of 80 ppb. In 2025, the latest year on file, its one sample was 5.8 ppb. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 43 ppb, in 2013.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”
One compound tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
  • Lead

Violations since 2016

Contaminant or ruleTypePeriodMeasuredStatus
Lead and Copper RuleA required study or plan for corrosion control was not done on time.EPA: OCCT/SOWT Study/RecommendationApril 1, 2023—Resolved
Lead and Copper RuleA required study or plan for corrosion control was not done on time.EPA: OCCT/SOWT Study/RecommendationMarch 31, 2023—Resolved
Health-based violations only. Resolved and archived mean the utility returned to compliance or the state closed the record. 11 monitoring or reporting violations not shown.

What this report can’t tell you

  • Everything else. Haloacetic acids (HAA5), nitrate and total trihalomethanes (TTHM) results here are Texas’s own from 2020 on, with EPA’s national file for 2012 to 2019. Sanford Municipal Water System’s own annual report, which it must send you every year, has the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; Texas’s results run from May 7, 2020 to July 14, 2026.

Testing your own tap

Sanford Municipal Water System’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab Texas certifies.

The lab Texas certifies closest to the area Sanford Municipal Water System serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

  • Environmental Monitoring Lab

    Amarillo, TX · about 43 miles

    Certified for bacteria

    (806) 335-9393

Texas Well Owner Network, Texas A&M AgriLife Extension: Well Informed screening events, where well owners bring in water samples to be screened for common contaminants, followed by an hour-long session explaining the results. Upcoming events are on the network's calendar. Trainings, Texas Well Owner Network.

All 80 certified labs for Texas

Sources