San Leon MUD
EPA’s and Texas’s records have results for 34 contaminants in its water; 8 were found.
In the name, MUD means municipal utility district.
Serves 11,622 people · Surface water bought from another system · San Leon, TX
- Serves
- 11,622 people
- Connections
- 3,874
- Water source
- Surface water bought from another system
- Based in
- San Leon, TX
- County
- Galveston
- Owner
- Local government
The ZIP code it serves
The short answer
None of the results here is above a limit in force today. Lithium is above EPA’s health benchmark. No health-based violations on file since 2016.
This is what the records show, not medical advice. Worried about a health effect? Talk to a doctor or your local health department.
What was found
Where these results come from, and when
PFAS and lithium: EPA UCMR 5, samples taken from July 26, 2024 to April 24, 2025.
Total trihalomethanes (TTHM), haloacetic acids (HAA5) and nitrate: Texas’s own results, samples taken from Jan. 15, 2020 to July 23, 2026, with EPA’s 2012 to 2019 file for earlier years.
What the lines mean
- Legal limit (MCL):
- Enforceable. The most a utility may deliver.
- Health goal (MCLG):
- Not enforceable. The level with no expected risk, with a margin of safety.
- Health benchmark:
- A screening level EPA uses where there is no legal limit or health goal, not an enforceable limit.
- Health reference level:
- A screening level from EPA’s work on whether to regulate a contaminant, where there is no legal limit or health goal; not enforceable.
PFAS: PFBS was found, of the six PFAS in EPA’s 2024 drinking water rule; its result is below. Three other PFAS with no federal limit were found, the highest PFPeA at 74.9 ppt: see them below.
Above EPA’s health benchmark, 1 result
Lithium
Comes from the source
17.5 ppb
Highest sample, April 24, 2025; found in 3 of 4
The highest sample was 17.5 ppb, above EPA’s health reference level of 10 ppb. That is a screening level, not an enforceable limit.
What handles it
No filter certification covers lithium yet, and EPA’s 2023 fact sheet says boiling doesn’t remove it. Because it was found, your utility has to report its lithium results in its annual water quality report, where newer ones will appear.
How to read your utility’s reportBelow EPA’s limits, 4 results
- Legal limit (MCL):
- Enforceable. The most a utility may deliver.
- Health benchmark:
- A screening level EPA uses where there is no legal limit or health goal, not an enforceable limit.
Total trihalomethanes (TTHM), Legal limit 80 ppb; highest yearly average 65.4 ppb
Highest yearly average, 2020 to 2026 · 2026 average: 42.6 ppb · Forms or is added in treatment
Averaged by year, the highest was 65.4 ppb, in 2023, below EPA’s legal limit of 80 ppb. Its highest single sample was 92.1 ppb. In 2026, the latest year on file, its 12 samples averaged below the limit. EPA recorded no violation for total trihalomethanes (TTHM) at this utility since 2020.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest yearly average of 63.9 ppb, in 2014.
What handles it
- NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
- NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”
Haloacetic acids (HAA5), Legal limit 60 ppb; highest yearly average 22.9 ppb
Highest yearly average, 2020 to 2026 · 2026 average: 12.7 ppb · Forms or is added in treatment
Averaged by year, the highest was 22.9 ppb, in 2023, below EPA’s legal limit of 60 ppb. Its highest single sample was 28.4 ppb. In 2026, the latest year on file, its 12 samples averaged below the limit.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest yearly average of 22.6 ppb, in 2015.
What handles it
No certification claim covers this compound yet.
Nitrate, Legal limit 10 ppm; highest 1.2 ppm
Highest sample; found in 6 of 7 · 2026, one sample: 0.51 ppm · Comes from the source
The highest sample, in 2021, was 1.2 ppm, below EPA’s legal limit of 10 ppm. In 2026, the latest year on file, its one sample was below the limit.
What handles it
- NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
- NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”
PFBS, Health benchmark 2,000 ppt; highest 3.4 ppt
Highest sample, April 24, 2025; found in 3 of 4 · Comes from the source
The highest sample was 3.4 ppt, below EPA’s health benchmark of 2,000 ppt. PFBS has no legal limit or health goal of its own.
What handles it
- NSF/ANSI 53 look for “Total PFAS Reduction”
EPA’s 2024 PFAS rule, compound by compoundAll six, found or not, and the Hazard Index, against the rule’s limits.
| PFAS | EPA’s limit | Result |
|---|---|---|
| PFOA | 4.0 ppt | Not foundNot found in any of 4 samples, below 4 ppt |
| PFOS | 4.0 ppt | Not foundNot found in any of 4 samples, below 4 ppt |
| PFHxS | 10 ppt | Not foundNot found in any of 4 samples, below 3 ppt |
| PFNA | 10 ppt | Not foundNot found in any of 4 samples, below 4 ppt |
| HFPO-DA (GenX) | 10 ppt | Not foundNot found in any of 4 samples, below 5 ppt |
| PFBS | Index only | Below EPA’s limits3.4 ppt highest, found in 3 of 4 samples. Details |
| Hazard IndexPFHxS, PFNA, HFPO-DA and PFBS together | 1 | Doesn’t applyDoesn’t apply: no sampling location found two or more of the four |
| Results from EPA’s UCMR 5 sampling. “Below” is the lab’s reporting level: a result under it reads as not found, which is not the same as zero. The limits are EPA’s 2024 rule, with compliance due from 2029; EPA has since proposed changes to some of them, explained on each compound’s page. PFBS has no limit of its own and counts only toward the Hazard Index, which adds up the four, each against EPA’s health-based level, from each sampling location’s average, as EPA’s UCMR 5 summary does. It counts only where two or more of the four were found, and is above the limit from 1.5. | ||
Also found, with no federal limit
EPA measured these PFAS to learn how often they occur. None has a legal limit or a health goal yet.
| Compound | Highest sample | Found in | Certification claim |
|---|---|---|---|
| PFPeA | 74.9 ppt | 4 of 4 | None covers it |
| PFBA | 30.8 ppt | 4 of 4 | None covers it |
| PFHxA | 4.4 ppt | 3 of 4 | None covers it |
26 compounds tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
From routine monitoring
- Lead
PFAS and lithium, from EPA’s UCMR 5 sampling
- 11Cl-PF3OUdS
- 4:2 FTS
- 6:2 FTS
- 8:2 FTS
- 9Cl-PF3ONS
- ADONA
- HFPO-DA (GenX)
- NEtFOSAA
- NFDHA
- NMeFOSAA
- PFDA
- PFDoA
- PFEESA
- PFHpA
- PFHpS
- PFHxS
- PFMBA
- PFMPA
- PFNA
- PFOA
- PFOS
- PFPeS
- PFTA
- PFTrDA
- PFUnA
Violations since 2016
No health-based violations on file with EPA since 2016. There are 16 monitoring or reporting violations: a sample missed, late or not reported. EPA’s file runs to 2026 Q3, so a notice your utility sent since then may not be here yet.
Disinfectant
San Leon MUD reported adding no disinfectant at its one sampling point, in its 2024 to 2025 sampling for EPA.
What that means
Most utilities add chlorine or chloramine, CDC says. This utility buys its water from another system, so what it reported may leave out treatment done before the water reaches it. This is what the utility reported for that sampling. Its annual water quality report says what it uses now.
What this report can’t tell you
Everything else. Total trihalomethanes (TTHM), haloacetic acids (HAA5) and nitrate results here are Texas’s own from 2020 on, with EPA’s national file for 2012 to 2019. San Leon MUD’s own annual report, which it must send you every year, has the contaminants this page does not show.
Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.
What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.
Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 samples are from July 26, 2024 to April 24, 2025; Texas’s results run from Jan. 15, 2020 to July 23, 2026.
Testing your own tap
What to test for at your tap
- Lead and copper. Both come mostly from a building’s own service line, solder and faucets, so a utility’s numbers can’t tell you yours. San Leon MUD’s latest lead sampling in EPA’s records, 2022 to 2024, had a 90th percentile of 0 ppb across the homes it sampled. The action level is 15 ppb, dropping to 10 ppb in November 2027, and EPA’s health goal for lead is zero. About lead.
- What San Leon MUD’s results flag: lithium. It is in the water the utility sends out, so a test of your tap mostly confirms it. Include it if you want a number for your own home.
The 3 labs Texas certifies closest to the area San Leon MUD serves, or a kit by mail
The 3 labs Texas certifies closest to the area San Leon MUD serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.
A & B Environmental Services, Inc.
Houston, TX · about 25 miles
Certified for bacteria, lead and copper
City of Houston Health Department, Bureau of Laboratory Services
Houston, TX · about 28 miles
Certified for bacteria
Brazoria County Health Department Water Laboratory
Angleton, TX · about 32 miles
Certified for bacteria
Or test by mail
Tap Score sells lab tests as kits you fill at your tap and mail back. The sample goes to Tap Score’s lab, not one near you, so check that Texas certifies it for the test you want.
Tap Score
- Lead and Copper Water Test, with a pH test strip: $55
- Essential City Water Test, 25 metals, 4 minerals, nitrate, fluoride, hardness and pH: $189
Return shipping included.
Tap Score says each kit ships to “an accredited laboratory” but doesn’t name it, so TapBuff can’t check it against Texas’s list.
Prices from Tap Score’s own store on Oct. 22, 2026.
What to do now
- Read up on lithiumWhat it does to health, where it comes from, and the certification claim that addresses it.About lithium
- Get the utility’s own reportSan Leon MUD must send you a water quality report every year. It covers contaminants this page does not show.How to read it
- Test your own tap for leadIts latest lead sampling found none at the 90th percentile, but your own service line, solder and fixtures decide the lead at your faucet.Lead in your water: what to do
Sources
- EPA UCMR 5 occurrence data, file of Oct. 15, 2026
- EPA SDWA bulk download (SDWIS federal data), 2026 Q3
- Texas Commission on Environmental Quality, Texas Drinking Water Viewer, results from Jan. 7, 2020 to Oct. 6, 2026, read Oct. 16, 2026
- EPA Six-Year Review 4 compliance monitoring data, 2012 to 2019, file of Feb. 5, 2024
- Disinfectant: EPA UCMR 5 occurrence data, additional data elements, file of Oct. 15, 2026
- Certified labs: TCEQ, drinking water laboratories approved for public water system samples, read Oct. 10, 2026; distances from the Census 2020 ZIP code tabulation area gazetteer
- Limits and goals: each contaminant’s page, with its EPA source.
- How this page is built: methodology.
PWSID TX0840063. Rebuilt from EPA data on Oct. 25, 2026.