What EPA’s and Texas’s records show in this utility’s water: nitrate, arsenic and other regulated chemicals; lead and copper; and violations since 2016, with the certification that handles each result.

Serves
936 people
Connections
312
Water source
Groundwater
Based in
Riviera, TX
County
Kleberg
Owner
Local government
The ZIP code it serves

78379

The short answer

1 result is above EPA’s legal limit, and 1 more is above the health goal. The worst: Uranium, above the legal limit. 39 health-based violations since 2016.

What handles it

What was found

Uranium, arsenic, total trihalomethanes (TTHM), fluoride, nitrate, haloacetic acids (HAA5) and chromium (total): Texas’s own results, samples taken from Feb. 26, 2020 to June 24, 2026, with EPA’s 2012 to 2019 file for earlier years.

Above the legal limit1

Uranium

Comes from the source

Above the legal limit

103ppb

Highest yearly average, 2020 to 2026

2026, one sample: 46.6 ppb

Averaged by year, the highest was 103 ppb, in 2022, about 3.4 times EPA’s legal limit of 30 ppb. Its highest single sample was 313 ppb. In 2026, the latest year on file, its one sample was 46.6 ppb, above the limit. EPA recorded violations for uranium at this utility in 2020, 2021, 2022, 2023, 2025 and 2026. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 86.6 ppb, in 2012, and EPA recorded violations in 2012, 2013, 2014, 2015, 2016, 2017, 2018 and 2019.

What handles it

Above the health goal1

Arsenic

Comes from the source

Above the health goal

4.3ppb

Highest yearly average, 2022 to 2025

2025, one sample: 2.9 ppb

Averaged by year, the highest was 4.3 ppb, in 2022: below EPA’s legal limit of 10 ppb, but above its health goal of zero. In 2025, the latest year on file, its one sample was 2.9 ppb. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 8.0 ppb, in 2016.

What handles it

  • NSF/ANSI 58 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
  • NSF/ANSI 53 look for “Arsenic (Pentavalent)<=50 ppb Reduction”

Below EPA’s limits4

Total trihalomethanes (TTHM)

Forms or is added in treatment

Below EPA’s limits

15.8ppb

Highest yearly average, 2020 to 2026

2026, one sample: 1.6 ppb

Averaged by year, the highest was 15.8 ppb, in 2024, below EPA’s legal limit of 80 ppb. In 2026, the latest year on file, its one sample was 1.6 ppb. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 9.9 ppb, in 2019.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”

Fluoride

Forms or is added in treatment

Below EPA’s limits

0.68ppm

Highest yearly average, 2021 to 2024

2024, one sample: 0.64 ppm

Averaged by year, the highest was 0.68 ppm, in 2021, below EPA’s legal limit of 4.0 ppm. In 2024, the latest year on file, its one sample was 0.64 ppm. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 0.74 ppm, in 2018.

What handles it

Nitrate

Comes from the source

Below EPA’s limits

0.78ppm

Highest sample; found in 7 of 7

2026, one sample: 0.64 ppm

The highest sample, in 2021, was 0.78 ppm, below EPA’s legal limit of 10 ppm. In 2026, the latest year on file, its one sample was 0.64 ppm. Earlier, from 2012 to 2019, EPA’s file shows a highest sample of 0.75 ppm, in 2019.

What handles it

  • NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
  • NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”

Haloacetic acids (HAA5)

Forms or is added in treatment

Below EPA’s limits

1.9ppb

Highest yearly average, 2020 to 2026

2026: not found

Averaged by year, the highest was 1.9 ppb, in 2024, below EPA’s legal limit of 60 ppb. In 2026, the latest year on file, it wasn’t found in its one sample. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 5.6 ppb, in 2019.

What handles it

No certification claim covers this compound yet.

2 compounds tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
  • Chromium (total)
  • Lead

What handles it

A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box. Wording varies a little: NSF writes “Lead Reduction,” WQA just “Lead.”

  • NSF/ANSI 53

    Claim: Arsenic (Pentavalent)<=50 ppb Reduction

    For: Arsenic

    Other certifiers’ wording: Arsenic (III) (50 ppb influent level)

  • NSF/ANSI 58

    Claims: Uranium, Arsenic (Pentavalent)<=50 ppb Reduction

    For: Uranium, Arsenic

    Other certifiers’ wording: Arsenic (Pentavalent)<=300 ppb Reduction; Arsenic (V) (300 ppb influent level)

At the tap, or for the whole house?

These come with the water itself, so a whole-house system certified for the same claims treats every tap and shower. A filter at the tap treats drinking water for much less. How whole-house systems compare.

Filters with those claims on a certifier’s listing

Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money

Compare five-year costs

The best reverse osmosis systems, ranked

Violations since 2016

Contaminant or ruleTypePeriodMeasuredStatus
Combined UraniumThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJan. 1, 2026 to March 31, 202646 UG/LArchived
Combined UraniumThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageOct. 1, 2025 to Dec. 31, 202539 UG/LArchived
Gross alpha radiation (excluding radon and uranium)The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJuly 1, 2023 to Sept. 30, 202323 PCI/LResolved
Combined UraniumThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageApril 1, 2023 to June 30, 202397 UG/LResolved
Gross alpha radiation (excluding radon and uranium)The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageApril 1, 2023 to June 30, 202323 PCI/LResolved
Combined UraniumThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJan. 1, 2023 to March 31, 202395 UG/LResolved
Gross alpha radiation (excluding radon and uranium)The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJan. 1, 2023 to March 31, 202323 PCI/LResolved
Gross alpha radiation (excluding radon and uranium)The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageOct. 1, 2022 to Dec. 31, 202223 PCI/LResolved
Combined UraniumThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageOct. 1, 2022 to Dec. 31, 2022103 UG/LResolved
Combined UraniumThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJuly 1, 2022 to Sept. 30, 202237 UG/LResolved
Combined UraniumThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageApril 1, 2022 to June 30, 202244 UG/LResolved
Combined UraniumThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJan. 1, 2022 to March 31, 202258 UG/LResolved
Combined UraniumThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageOct. 1, 2021 to Dec. 31, 202162 UG/LResolved
Combined UraniumThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJuly 1, 2021 to Sept. 30, 202152 UG/LResolved
Combined UraniumThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageApril 1, 2021 to June 30, 202143 UG/LResolved
Combined UraniumThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJan. 1, 2020 to March 31, 202043 UG/LResolved
Groundwater RuleA significant problem found in a state inspection was not fixed on time.EPA: Failure To Address DeficiencyOct. 17, 2019—Resolved
Combined UraniumThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageOct. 1, 2019 to Dec. 31, 201957 UG/LResolved
Combined UraniumThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJuly 1, 2019 to Sept. 30, 201974 UG/LResolved
Gross alpha radiation (excluding radon and uranium)The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJuly 1, 2019 to Sept. 30, 201919 PCI/LResolved
Combined UraniumThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageApril 1, 2019 to June 30, 201976 UG/LResolved
Gross alpha radiation (excluding radon and uranium)The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageApril 1, 2019 to June 30, 201920 PCI/LResolved
Gross alpha radiation (excluding radon and uranium)The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJan. 1, 2019 to March 31, 201919 PCI/LResolved
Combined UraniumThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJan. 1, 2019 to March 31, 201975 UG/LResolved
Gross alpha radiation (excluding radon and uranium)The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageOct. 1, 2018 to Dec. 31, 201824 PCI/LResolved
Combined UraniumThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageOct. 1, 2018 to Dec. 31, 201876 UG/LResolved
Combined UraniumThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJuly 1, 2018 to Sept. 30, 201877 UG/LResolved
Combined UraniumThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageApril 1, 2018 to June 30, 201876 UG/LResolved
Combined UraniumThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJan. 1, 2018 to March 31, 201876 UG/LResolved
Combined UraniumThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageOct. 1, 2017 to Dec. 31, 201776 UG/LResolved
Combined UraniumThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJuly 1, 2017 to Sept. 30, 201774 UG/LResolved
Combined UraniumThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageApril 1, 2017 to June 30, 201772 UG/LResolved
Gross alpha radiation (excluding radon and uranium)The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageApril 1, 2017 to June 30, 201717 PCI/LResolved
Gross alpha radiation (excluding radon and uranium)The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJan. 1, 2017 to March 31, 201717 PCI/LResolved
Combined UraniumThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJan. 1, 2017 to March 31, 201772 UG/LResolved
Combined UraniumThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageOct. 1, 2016 to Dec. 31, 201671 UG/LResolved
Combined UraniumThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJuly 1, 2016 to Sept. 30, 201672 UG/LResolved
Combined UraniumThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageApril 1, 2016 to June 30, 201670 UG/LResolved
Combined UraniumThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJan. 1, 2016 to March 31, 201670 UG/LResolved
Health-based violations only. Resolved and archived mean the utility returned to compliance or the state closed the record. 28 monitoring or reporting violations not shown.

What this report can’t tell you

  • Everything else. Uranium, arsenic, total trihalomethanes (TTHM), fluoride, nitrate, haloacetic acids (HAA5) and chromium (total) results here are Texas’s own from 2020 on, with EPA’s national file for 2012 to 2019. Riviera WCID’s own annual report, which it must send you every year, has the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; Texas’s results run from Feb. 26, 2020 to June 24, 2026.

Testing your own tap

Riviera WCID’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab Texas certifies.

The lab Texas certifies closest to the area Riviera WCID serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

  • Corpus Christi -Nueces County Public Health District Laboratory

    Corpus Christi, TX · about 37 miles

    Certified for bacteria

    (361) 826-7213

Texas Well Owner Network, Texas A&M AgriLife Extension: Well Informed screening events, where well owners bring in water samples to be screened for common contaminants, followed by an hour-long session explaining the results. Upcoming events are on the network's calendar. Trainings, Texas Well Owner Network.

All 80 certified labs for Texas

Sources

PWSID TX1370007. Rebuilt from EPA data on Oct. 18, 2026.