Skip to content
TapBuff

North Runnels WSC

What EPA’s and Texas’s records show in this utility’s water: nitrate, arsenic and other regulated chemicals; lead and copper; and violations since 2016, with the certification that handles each result.

Serves
2,766 people
Connections
1,000
Water source
Surface water bought from another system
Based in
Winters, TX
County
Runnels
Owner
Local government
The 6 ZIP codes it serves

76821, 76865, 76882, 79541, 79566, 79567

The short answer

2 results are above EPA’s legal limit. The worst: Haloacetic acids (HAA5), above the legal limit. 12 health-based violations since 2016.

What handles it

What was found

Haloacetic acids (HAA5), total trihalomethanes (TTHM) and nitrate: Texas’s own results, samples taken from March 24, 2020 to July 30, 2026, with EPA’s 2012 to 2019 file for earlier years.

Above the legal limit2

Haloacetic acids (HAA5)

Forms or is added in treatment

Above the legal limit

96.2ppb

Highest yearly average, 2020 to 2026

2026 average: 18.9 ppb

Averaged by year, the highest was 96.2 ppb, in 2020, above EPA’s legal limit of 60 ppb. Its highest single sample was 413 ppb. In 2026, the latest year on file, its six samples averaged 18.9 ppb. EPA recorded violations for haloacetic acids (HAA5) at this utility in 2020 and 2021. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 39.8 ppb, in 2018, and EPA recorded a violation in 2018.

What handles it

No certification claim covers this compound yet.

Total trihalomethanes (TTHM)

Forms or is added in treatment

Above the legal limit

98.2ppb

Highest yearly average, 2020 to 2026

2026 average: 13.1 ppb

Averaged by year, the highest was 98.2 ppb, in 2020, above EPA’s legal limit of 80 ppb. Its highest single sample was 435 ppb. In 2026, the latest year on file, its six samples averaged 13.1 ppb. EPA recorded violations for total trihalomethanes (TTHM) at this utility in 2020 and 2021. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 170 ppb, in 2012, and EPA recorded violations in 2012 and 2013.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”

Below EPA’s limits1

Nitrate

Comes from the source

Below EPA’s limits

0.22ppm

Highest sample; found in 7 of 7

2026, one sample: 0.12 ppm

The highest sample, in 2024, was 0.22 ppm, below EPA’s legal limit of 10 ppm. In 2026, the latest year on file, its one sample was 0.12 ppm.

What handles it

  • NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
  • NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”
One compound tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
  • Lead

What handles it

A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box. Wording varies a little: NSF writes “Lead Reduction,” WQA just “Lead.”

  • NSF/ANSI 53

    Claim: Trihalomethanes (TTHM) Reduction

    For: Total trihalomethanes (TTHM)

    Other certifiers’ wording: VOC Reduction

  • NSF/ANSI 58

    Claim: Trihalomethanes (TTHM) Reduction

    For: Total trihalomethanes (TTHM)

At the tap, or for the whole house?

These come with the water itself, so a whole-house system certified for the same claims treats every tap and shower. A filter at the tap treats drinking water for much less. How whole-house systems compare.

Filters with those claims on a certifier’s listing

Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money

Compare five-year costs

Violations since 2016

Contaminant or ruleTypePeriodMeasuredStatus
Total Haloacetic Acids (HAA5)The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageApril 1, 2021 to June 30, 20210.1 MG/LResolved
TTHMThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageApril 1, 2021 to June 30, 20210.11 MG/LResolved
TTHMThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJan. 1, 2021 to March 31, 20210.11 MG/LResolved
Total Haloacetic Acids (HAA5)The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJan. 1, 2021 to March 31, 20210.11 MG/LResolved
TTHMThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageOct. 1, 2020 to Dec. 31, 20200.14 MG/LResolved
Total Haloacetic Acids (HAA5)The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageOct. 1, 2020 to Dec. 31, 20200.13 MG/LResolved
TTHMThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJuly 1, 2020 to Sept. 30, 20200.12 MG/LResolved
Total Haloacetic Acids (HAA5)The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJuly 1, 2020 to Sept. 30, 20200.12 MG/LResolved
Total Haloacetic Acids (HAA5)The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageApril 1, 2020 to June 30, 20200.064 MG/LResolved
Total Haloacetic Acids (HAA5)The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJan. 1, 2020 to March 31, 20200.067 MG/LResolved
Total Haloacetic Acids (HAA5)The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageApril 1, 2018 to June 30, 20180.067 MG/LResolved
Total Haloacetic Acids (HAA5)The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJan. 1, 2018 to March 31, 20180.068 MG/LResolved
Health-based violations only. Resolved and archived mean the utility returned to compliance or the state closed the record. 19 monitoring or reporting violations not shown.

What this report can’t tell you

  • Everything else. Haloacetic acids (HAA5), total trihalomethanes (TTHM) and nitrate results here are Texas’s own from 2020 on, with EPA’s national file for 2012 to 2019. North Runnels WSC’s own annual report, which it must send you every year, has the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; Texas’s results run from March 24, 2020 to July 30, 2026.

Testing your own tap

North Runnels WSC’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab Texas certifies.

The 3 labs Texas certifies closest to the area North Runnels WSC serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

  • SKG Engineering, LLC

    San Angelo, TX · about 43 miles

    Certified for bacteria

    (325) 655-1288

  • Sweetwater -Nolan County Health Department

    Sweetwater, TX · about 43 miles

    Certified for bacteria

    (325) 235-5463

  • Abilene–Taylor County Public Health District

    Abilene, TX · about 47 miles

    Certified for bacteria

    (325) 692-5600

Texas Well Owner Network, Texas A&M AgriLife Extension: Well Informed screening events, where well owners bring in water samples to be screened for common contaminants, followed by an hour-long session explaining the results. Upcoming events are on the network's calendar. Trainings, Texas Well Owner Network.

All 80 certified labs for Texas

Sources

PWSID TX2000005. Rebuilt from EPA data on Oct. 18, 2026.