Skip to content
TapBuff

North Austin MUD 1

EPA’s and Texas’s records have results for 34 contaminants in its water; 3 were found.

In the name, MUD means municipal utility district.

Serves 11,133 people · Surface water bought from another system · Austin, TX

Serves
11,133 people
Connections
2,710
Water source
Surface water bought from another system
Based in
Austin, TX
County
Travis
Owner
Local government
The 2 ZIP codes it serves

78717, 78729

The short answer

None of the results here is above a limit in force today. That covers PFAS and lithium; nitrate, arsenic and other regulated chemicals; and lead and copper, not everything. No health-based violations on file since 2016.

What was found

Where these results come from, and when

PFAS and lithium: EPA UCMR 5, samples taken from Aug. 22, 2023 to May 13, 2024.

Total trihalomethanes (TTHM), haloacetic acids (HAA5) and nitrate: Texas’s own results, samples taken from Feb. 27, 2020 to July 6, 2026, with EPA’s 2012 to 2019 file for earlier years.

What the lines mean
Legal limit (MCL):
Enforceable. The most a utility may deliver.
Health goal (MCLG):
Not enforceable. The level with no expected risk, with a margin of safety.

PFAS: None of the six PFAS in EPA’s 2024 drinking water rule was found in this utility’s samples. None of the other 23 PFAS tested for was found either.

Below EPA’s limits, 3 results

Legal limit (MCL):
Enforceable. The most a utility may deliver.
Total trihalomethanes (TTHM), Legal limit 80 ppb; highest yearly average 45.8 ppb

Highest yearly average, 2020 to 2026 · Forms or is added in treatment

Averaged by year, the highest was 45.8 ppb, in 2026, below EPA’s legal limit of 80 ppb. Its highest single sample was 60.3 ppb. That was also the latest year on file.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 47 ppb, in 2015.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”
About total trihalomethanes (TTHM)
Haloacetic acids (HAA5), Legal limit 60 ppb; highest yearly average 15.9 ppb

Highest yearly average, 2020 to 2026 · Forms or is added in treatment

Averaged by year, the highest was 15.9 ppb, in 2026, below EPA’s legal limit of 60 ppb. Its highest single sample was 21.2 ppb. That was also the latest year on file.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 17.3 ppb, in 2019.

What handles it

No certification claim covers this compound yet.

About haloacetic acids (HAA5)
Nitrate, Legal limit 10 ppm; highest 0.19 ppm

Highest sample; found in 5 of 7 · 2026: not found · Comes from the source

The highest sample, in 2024, was 0.19 ppm, below EPA’s legal limit of 10 ppm. In 2026, the latest year on file, it wasn’t found in its one sample.

What handles it

  • NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
  • NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”
About nitrate
Texas utilities above EPA’s PFAS limits⁠
31 compounds tested and not foundIncluding all six PFAS in EPA’s 2024 rule. Below the reporting level in every sample. Not found is not the same as zero.

From routine monitoring

  • Lead

PFAS and lithium, from EPA’s UCMR 5 sampling

  • 11Cl-PF3OUdS
  • 4:2 FTS
  • 6:2 FTS
  • 8:2 FTS
  • 9Cl-PF3ONS
  • ADONA
  • HFPO-DA (GenX)
  • Lithium
  • NEtFOSAA
  • NFDHA
  • NMeFOSAA
  • PFBA
  • PFBS
  • PFDA
  • PFDoA
  • PFEESA
  • PFHpA
  • PFHpS
  • PFHxA
  • PFHxS
  • PFMBA
  • PFMPA
  • PFNA
  • PFOA
  • PFOS
  • PFPeA
  • PFPeS
  • PFTA
  • PFTrDA
  • PFUnA

Violations since 2016

No health-based violations on file with EPA since 2016. EPA’s file runs to 2026 Q3, so a notice your utility sent since then may not be here yet.

Disinfectant

North Austin MUD 1 reported adding chloramine before water enters its pipes, at its one sampling point, in its 2023 to 2024 sampling for EPA.

What that means

Chloramine is chlorine combined with ammonia. It lasts longer in the pipes, and unlike chlorine, it doesn’t leave water that sits out. A filter’s chlorine claim doesn’t cover it: look for the separate chloramine claim under NSF/ANSI 42. No shower filter can carry one: NSF/ANSI 177, the shower filter standard, covers free chlorine only. Fish, turtles and frogs need it removed from their water. This utility buys its water from another system, so what it reported may leave out treatment done before the water reaches it. This is what the utility reported for that sampling. Its annual water quality report says what it uses now.

What this report can’t tell you

  • Everything else. Total trihalomethanes (TTHM), haloacetic acids (HAA5) and nitrate results here are Texas’s own from 2020 on, with EPA’s national file for 2012 to 2019. North Austin MUD 1’s own annual report, which it must send you every year, has the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 samples are from Aug. 22, 2023 to May 13, 2024; Texas’s results run from Feb. 27, 2020 to July 6, 2026.

Testing your own tap

North Austin MUD 1’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab Texas certifies.

What to test for at your tap

  • Lead and copper. Both come mostly from a building’s own service line, solder and faucets, so a utility’s numbers can’t tell you yours. North Austin MUD 1’s latest lead sampling in EPA’s records, 2023 to 2025, had a 90th percentile of 0 ppb across the homes it sampled. The action level is 15 ppb, dropping to 10 ppb in November 2027, and EPA’s health goal for lead is zero. About lead.
The 3 labs Texas certifies closest to the area North Austin MUD 1 serves, or a kit by mail

The 3 labs Texas certifies closest to the area North Austin MUD 1 serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

  • Integrity Testing, Inc.

    Austin, TX · about 5 miles

    Certified for lead and copper

    (512) 891-7777

  • Texas Department of State Health Services Laboratory Services Section

    Austin, TX · about 11 miles

    Certified for bacteria, lead and copper

    (512) 458-7318

  • Aqua-Tech Laboratories, Inc.

    Austin, TX · about 21 miles

    Certified for bacteria, lead and copper

    (512) 301-9559

All 80 certified labs for Texas⁠

Or test by mail

Tap Score sells lab tests as kits you fill at your tap and mail back. The sample goes to Tap Score’s lab, not one near you, so check that Texas certifies it for the test you want.

  • Tap Score

    Return shipping included.

    Tap Score says each kit ships to “an accredited laboratory” but doesn’t name it, so TapBuff can’t check it against Texas’s list.

Prices from Tap Score’s own store on Oct. 22, 2026.

What to do now

Sources

PWSID TX2270226. Rebuilt from EPA data on Oct. 25, 2026.