Skip to content
TapBuff

Myrtle Springs WSC

What EPA’s and Texas’s records show in this utility’s water: nitrate, arsenic and other regulated chemicals; lead and copper; and violations since 2016, with the certification that handles each result.

Serves
2,289 people
Connections
763
Water source
Groundwater
Based in
Canton, TX
County
Van Zandt
Owner
Local government
The 2 ZIP codes it serves

75103, 75169

The short answer

1 result is above the health goal. The worst: Arsenic, above the health goal. No health-based violations on file since 2016.

What handles it

What was found

Arsenic, total trihalomethanes (TTHM), haloacetic acids (HAA5), chromium (total), fluoride, nitrate and uranium: Texas’s own results, samples taken from March 4, 2020 to June 18, 2026, with EPA’s 2012 to 2019 file for earlier years.

Above the health goal1

Arsenic

Comes from the source

Above the health goal

0.55ppb

Highest yearly average, 2020 to 2026

2026: not found

Averaged by year, the highest was 0.55 ppb, in 2020: below EPA’s legal limit of 10 ppb, but above its health goal of zero. Its highest single sample was 1.1 ppb. In 2026, the latest year on file, it wasn’t found in any of its two samples.

What handles it

  • NSF/ANSI 58 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
  • NSF/ANSI 53 look for “Arsenic (Pentavalent)<=50 ppb Reduction”

Below EPA’s limits5

Total trihalomethanes (TTHM)

Forms or is added in treatment

Below EPA’s limits

62.9ppb

Highest yearly average, 2020 to 2026

2026 average: 54.4 ppb

Averaged by year, the highest was 62.9 ppb, in 2023, below EPA’s legal limit of 80 ppb. Its highest single sample was 65 ppb. In 2026, the latest year on file, its two samples averaged 54.4 ppb. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 58.5 ppb, in 2014.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”

Haloacetic acids (HAA5)

Forms or is added in treatment

Below EPA’s limits

12.8ppb

Highest yearly average, 2020 to 2026

2026 average: 9.0 ppb

Averaged by year, the highest was 12.8 ppb, in 2024, below EPA’s legal limit of 60 ppb. Its highest single sample was 13.2 ppb. In 2026, the latest year on file, its two samples averaged 9.0 ppb. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 26.1 ppb, in 2018.

What handles it

No certification claim covers this compound yet.

Chromium (total)

Comes from the source

Below EPA’s limits

3.5ppb

Highest yearly average, 2020 to 2026

2026 average: 1.1 ppb

Averaged by year, the highest was 3.5 ppb, in 2021, below EPA’s legal limit of 100 ppb. In 2026, the latest year on file, its two samples averaged 1.1 ppb. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 1.6 ppb, in 2015.

What handles it

Fluoride

Forms or is added in treatment

Below EPA’s limits

0.13ppm

Highest yearly average, 2020 to 2026

2026 average: 0.087 ppm

Averaged by year, the highest was 0.13 ppm, in 2022, below EPA’s legal limit of 4.0 ppm. In 2026, the latest year on file, its two samples averaged 0.087 ppm. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 0.15 ppm, in 2014.

What handles it

Nitrate

Comes from the source

Below EPA’s limits

0.17ppm

Highest sample; found in 28 of 28

2026 average: 0.043 ppm

The highest sample, in 2025, was 0.17 ppm, below EPA’s legal limit of 10 ppm. In 2026, the latest year on file, its four samples averaged 0.043 ppm. Earlier, from 2012 to 2019, EPA’s file shows a highest sample of 0.18 ppm, in 2019.

What handles it

  • NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
  • NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”
2 compounds tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
  • Lead
  • Uranium

What handles it

A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box. Wording varies a little: NSF writes “Lead Reduction,” WQA just “Lead.”

  • NSF/ANSI 53

    Claim: Arsenic (Pentavalent)<=50 ppb Reduction

    For: Arsenic

    Other certifiers’ wording: Arsenic (III) (50 ppb influent level)

  • NSF/ANSI 58

    Claim: Arsenic (Pentavalent)<=50 ppb Reduction

    For: Arsenic

    Other certifiers’ wording: Arsenic (Pentavalent)<=300 ppb Reduction; Arsenic (V) (300 ppb influent level)

At the tap, or for the whole house?

These come with the water itself, so a whole-house system certified for the same claims treats every tap and shower. A filter at the tap treats drinking water for much less. How whole-house systems compare.

Filters with those claims on a certifier’s listing

Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money

Compare five-year costs

The best reverse osmosis systems, ranked

Violations since 2016

No health-based violations on file with EPA since 2016. There are 11 monitoring or reporting violations: a sample missed, late or not reported.

What this report can’t tell you

  • Everything else. Arsenic, total trihalomethanes (TTHM), haloacetic acids (HAA5), chromium (total), fluoride, nitrate and uranium results here are Texas’s own from 2020 on, with EPA’s national file for 2012 to 2019. Myrtle Springs WSC’s own annual report, which it must send you every year, has the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; Texas’s results run from March 4, 2020 to June 18, 2026.

Testing your own tap

Myrtle Springs WSC’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab Texas certifies.

The 3 labs Texas certifies closest to the area Myrtle Springs WSC serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

  • Northeast Texas Public Health District Laboratory

    Tyler, TX · about 40 miles

    Certified for bacteria

    (903) 535-0090

  • Analytical Environmental Labs

    Tyler, TX · about 44 miles

    Certified for bacteria

    (903) 509-8700

  • Environmental Monitoring Lab

    Winona, TX · about 50 miles

    Certified for bacteria

    (903) 877-9222

Texas Well Owner Network, Texas A&M AgriLife Extension: Well Informed screening events, where well owners bring in water samples to be screened for common contaminants, followed by an hour-long session explaining the results. Upcoming events are on the network's calendar. Trainings, Texas Well Owner Network.

All 80 certified labs for Texas

Sources

PWSID TX2340014. Rebuilt from EPA data on Oct. 18, 2026.