Mustang SUD
EPA’s and Texas’s records have results for 38 contaminants in its water; 11 were found.
In the name, SUD means special utility district.
Serves 127,911 people · Surface water bought from another system · Aubrey, TX
- Serves
- 127,911 people
- Connections
- 42,637
- Water source
- Surface water bought from another system
- Based in
- Aubrey, TX
- County
- Denton
- Owner
- Local government
The short answer
None of the results here is above a limit in force today. Lithium is above EPA’s health benchmark. No health-based violations on file since 2016.
This is what the records show, not medical advice. Worried about a health effect? Talk to a doctor or your local health department.
What was found
Where these results come from, and when
PFAS and lithium: EPA UCMR 5, samples taken from Jan. 27 to Oct. 27, 2025.
Lead and copper: EPA SDWIS monitoring periods ending 2016 to 2025.
Fluoride, total trihalomethanes (TTHM), haloacetic acids (HAA5), arsenic, nitrate, chromium (total) and uranium: Texas’s own results, samples taken from Jan. 9, 2020 to Sept. 21, 2026, with EPA’s 2012 to 2019 file for earlier years.
What the lines mean
- Legal limit (MCL):
- Enforceable. The most a utility may deliver.
- Action level:
- Triggers action. If more than 10% of homes sampled are above it, the utility must act.
- 90th percentile:
- How a lead or copper result is held against its action level: nine in ten of the homes sampled were at or below it.
- Health goal (MCLG):
- Not enforceable. The level with no expected risk, with a margin of safety.
- Health reference level:
- A screening level from EPA’s work on whether to regulate a contaminant, where there is no legal limit or health goal; not enforceable.
PFAS: None of the six PFAS in EPA’s 2024 drinking water rule was found in this utility’s samples. Three other PFAS with no federal limit were found, the highest PFBA at 6.4 ppt: see them below.
Above EPA’s health benchmark, 1 result
Lithium
Comes from the source
41.2 ppb
Highest sample, Jan. 27, 2025; found in 16 of 21
The highest sample was 41.2 ppb, about 4.1 times EPA’s health reference level of 10 ppb. That is a screening level, not an enforceable limit.
What handles it
No filter certification covers lithium yet, and EPA’s 2023 fact sheet says boiling doesn’t remove it. Because it was found, your utility has to report its lithium results in its annual water quality report, where newer ones will appear.
How to read your utility’s reportBelow EPA’s limits, 7 results
Lead and arsenic have a health goal of zero: the level with no known or expected risk. Any amount found is above it, but the goal isn’t a limit.
- Legal limit (MCL):
- Enforceable. The most a utility may deliver.
- Action level:
- Triggers action. If more than 10% of homes sampled are above it, the utility must act.
- 90th percentile:
- How a lead or copper result is held against its action level: nine in ten of the homes sampled were at or below it.
Fluoride, Legal limit 4.0 ppm; highest yearly average 1.4 ppm
Highest yearly average, 2020 to 2026 · 2026 average: 0.3 ppm · Forms or is added in treatment
Averaged by year, the highest was 1.4 ppm, in 2025, below EPA’s legal limit of 4.0 ppm. Its highest single sample was 1.6 ppm. In 2026, the latest year on file, its eight samples averaged below the limit.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest yearly average of 0.51 ppm, in 2014.
What handles it
- NSF/ANSI 58 look for “Fluoride Reduction”
- NSF/ANSI 53 look for “Fluoride”
Total trihalomethanes (TTHM), Legal limit 80 ppb; highest yearly average 28.1 ppb
Highest yearly average, 2020 to 2026 · 2026 average: 19 ppb · Forms or is added in treatment
Averaged by year, the highest was 28.1 ppb, in 2021, below EPA’s legal limit of 80 ppb. Its highest single sample was 35.9 ppb. In 2026, the latest year on file, its 12 samples averaged below the limit.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest yearly average of 44.5 ppb, in 2014.
What handles it
- NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
- NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”
Haloacetic acids (HAA5), Legal limit 60 ppb; highest yearly average 16.2 ppb
Highest yearly average, 2020 to 2026 · 2026 average: 10.4 ppb · Forms or is added in treatment
Averaged by year, the highest was 16.2 ppb, in 2021, below EPA’s legal limit of 60 ppb. Its highest single sample was 25.8 ppb. In 2026, the latest year on file, its 12 samples averaged below the limit.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest yearly average of 29.2 ppb, in 2016.
What handles it
No certification claim covers this compound yet.
Lead, Action level 15 ppb · health goal zero; 90th percentile 1.3 ppb
90th percentile, 2025 · Comes from pipes, often your own
In the latest period, 9 in 10 homes sampled were at or below 1.3 ppb, below EPA’s action level of 15 ppb. The action level drops to 10 ppb on Nov. 1, 2027. EPA’s health goal for lead is zero.
What handles it
- NSF/ANSI 53 look for “Lead Reduction”
- NSF/ANSI 58 look for “Lead Reduction”
Arsenic, Legal limit 10 ppb · health goal zero; highest yearly average 0.88 ppb
Highest yearly average, 2020 to 2026 · Comes from the source
Averaged by year, the highest was 0.88 ppb, in 2026, below EPA’s legal limit of 10 ppb. Its health goal is zero, so any amount found is above it; the goal isn’t a limit. Its highest single sample was 1.8 ppb. That was also the latest year on file.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest yearly average of 0.25 ppb, in 2019.
What handles it
- NSF/ANSI 58 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
- NSF/ANSI 53 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
Nitrate, Legal limit 10 ppm; highest 0.73 ppm
Highest sample; found in 85 of 95 · 2026 average: 0.15 ppm · Comes from the source
The highest sample, in 2024, was 0.73 ppm, below EPA’s legal limit of 10 ppm. In 2026, the latest year on file, its 15 samples averaged below the limit.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest sample of 1.7 ppm, in 2015.
What handles it
- NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
- NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”
Chromium (total), Legal limit 100 ppb; highest yearly average 5.0 ppb
Highest yearly average, 2020 to 2026 · 2026 average: 0.42 ppb · Comes from the source
Averaged by year, the highest was 5.0 ppb, in 2020, below EPA’s legal limit of 100 ppb. Its highest single sample was 8.1 ppb. In 2026, the latest year on file, its four samples averaged below the limit.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest yearly average of 4.4 ppb, in 2017.
What handles it
- NSF/ANSI 58 look for “Chromium (Hexavalent) Reduction”
- NSF/ANSI 53 look for “Chromium Reduction”
Also found, with no federal limit
EPA measured these PFAS to learn how often they occur. None has a legal limit or a health goal yet.
| Compound | Highest sample | Found in | Certification claim |
|---|---|---|---|
| PFBA | 6.4 ppt | 1 of 20 | None covers it |
| PFPeA | 4.0 ppt | 1 of 20 | None covers it |
| PFHxA | 3.7 ppt | 1 of 20 | None covers it |
27 compounds tested and not foundIncluding all six PFAS in EPA’s 2024 rule. Below the reporting level in every sample. Not found is not the same as zero.
From routine monitoring
- Uranium
PFAS and lithium, from EPA’s UCMR 5 sampling
- 11Cl-PF3OUdS
- 4:2 FTS
- 6:2 FTS
- 8:2 FTS
- 9Cl-PF3ONS
- ADONA
- HFPO-DA (GenX)
- NEtFOSAA
- NFDHA
- NMeFOSAA
- PFBS
- PFDA
- PFDoA
- PFEESA
- PFHpA
- PFHpS
- PFHxS
- PFMBA
- PFMPA
- PFNA
- PFOA
- PFOS
- PFPeS
- PFTA
- PFTrDA
- PFUnA
Violations since 2016
No health-based violations on file with EPA since 2016. There are 6 monitoring or reporting violations: a sample missed, late or not reported. EPA’s file runs to 2026 Q3, so a notice your utility sent since then may not be here yet.
What handles it
A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box.
- NSF/ANSI 53
Claims: Lead Reduction, Arsenic (Pentavalent)<=50 ppb Reduction
For: Lead, Arsenic
Other claims that cover it: Arsenic (III) (50 ppb influent level)
- NSF/ANSI 58
Claims: Lead Reduction, Arsenic (Pentavalent)<=50 ppb Reduction
For: Lead, Arsenic
Other claims that cover it: Arsenic (Pentavalent)<=300 ppb Reduction; Arsenic (V) (300 ppb influent level)
At the tap, or for the whole house?
These come with the water itself, so a whole-house system certified for the same claims treats every tap and shower. A filter at the tap treats drinking water for much less. How whole-house systems compare.
Filters with those claims on a certifier’s listing
Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money
Under-sink reverse osmosis
Five years: $549, household of 3, cartridges included
WQA listing: NSF/ANSI 58, checked Oct. 9, 2026
Certified for: Lead, Arsenic
Countertop reverse osmosis
Five years: $1,344, household of 3, cartridges included
Certified for: Lead, Arsenic
Brondell Capella RC250 Reverse Osmosis System
Under-sink reverse osmosis
Five years: $1,950, household of 3, cartridges included
Certified for: Lead, Arsenic
2 more filters
Aquasana SmartFlow Reverse Osmosis (AQ-SFRO2)
Under-sink reverse osmosis
Five years: $2,917, household of 3, cartridges included
Certified for: Lead, Arsenic
Express Water StreamLine Direct Connect System (USC001)
Under-sink carbon
Five years: $527, household of 3, cartridges included
Certified for: Lead
Every filter for these, those that cover both first
Disinfectant
Mustang SUD reported chloramine at 9 of its 10 sampling points and chlorine without chloramine at 1, in its 2025 sampling for EPA. Which one reaches your tap can depend on where you live. It also reported ozone.
What that means
Chloramine is chlorine combined with ammonia. It lasts longer in the pipes, and unlike chlorine, it doesn’t leave water that sits out. A filter’s chlorine claim doesn’t cover it: look for the separate chloramine claim under NSF/ANSI 42. No shower filter can carry one: NSF/ANSI 177, the shower filter standard, covers free chlorine only. Fish, turtles and frogs need it removed from their water. This utility buys its water from another system, so what it reported may leave out treatment done before the water reaches it. This is what the utility reported for that sampling. Its annual water quality report says what it uses now.
What this report can’t tell you
Everything else. Fluoride, total trihalomethanes (TTHM), haloacetic acids (HAA5), arsenic, nitrate, chromium (total) and uranium results here are Texas’s own from 2020 on, with EPA’s national file for 2012 to 2019. Mustang SUD’s own annual report, which it must send you every year, has the contaminants this page does not show.
Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.
What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.
Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 samples are from Jan. 27 to Oct. 27, 2025; Texas’s results run from Jan. 9, 2020 to Sept. 21, 2026.
Testing your own tap
What to test for at your tap
- Lead and copper. Both come mostly from a building’s own service line, solder and faucets, so a utility’s numbers can’t tell you yours. Mustang SUD’s latest lead sampling in EPA’s records, 2025, had a 90th percentile of 1.3 ppb: 9 in 10 of the homes it sampled were at or below that. The action level is 15 ppb, dropping to 10 ppb in November 2027, and EPA’s health goal for lead is zero. About lead.
- What Mustang SUD’s results flag: lithium. It is in the water the utility sends out, so a test of your tap mostly confirms it. Include it if you want a number for your own home.
The 3 labs Texas certifies closest to the area Mustang SUD serves, or a kit by mail
The 3 labs Texas certifies closest to the area Mustang SUD serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.
Pace Analytical Services, LLC -Dallas TX
Allen, TX · about 19 miles
Certified for bacteria
Southern Petroleum Laboratories, Inc. - Plano
Plano, TX · about 25 miles
Certified for bacteria, lead and copper
Eurofins Xenco, LLC -Dallas
Dallas, TX · about 33 miles
Certified for bacteria
Or test by mail
Tap Score sells lab tests as kits you fill at your tap and mail back. The sample goes to Tap Score’s lab, not one near you, so check that Texas certifies it for the test you want.
Tap Score
- Lead and Copper Water Test, with a pH test strip: $55
- Essential City Water Test, 25 metals, 4 minerals, nitrate, fluoride, hardness and pH: $189
Return shipping included.
Tap Score says each kit ships to “an accredited laboratory” but doesn’t name it, so TapBuff can’t check it against Texas’s list.
Prices from Tap Score’s own store on Oct. 22, 2026.
What to do now
- Read up on lithiumWhat it does to health, where it comes from, and the certification claim that addresses it.About lithium
- Get the utility’s own reportMustang SUD must send you a water quality report every year. It covers contaminants this page does not show.How to read it
- Test your own tap for leadYour service line, solder and fixtures decide the lead at your faucet, not the utility’s average.Lead in your water: what to do
Sources
- EPA UCMR 5 occurrence data, file of Oct. 15, 2026
- EPA SDWA bulk download (SDWIS federal data), 2026 Q3
- Texas Commission on Environmental Quality, Texas Drinking Water Viewer, results from Jan. 7, 2020 to Oct. 6, 2026, read Oct. 16, 2026
- EPA Six-Year Review 4 compliance monitoring data, 2012 to 2019, file of Feb. 5, 2024
- Disinfectant: EPA UCMR 5 occurrence data, additional data elements, file of Oct. 15, 2026
- Certified labs: TCEQ, drinking water laboratories approved for public water system samples, read Oct. 10, 2026; distances from the Census 2020 ZIP code tabulation area gazetteer
- Limits and goals: each contaminant’s page, with its EPA source.
- How this page is built: methodology.
PWSID TX0610036. Rebuilt from EPA data on Oct. 25, 2026.