Murvaul WSC
What EPA’s and Texas’s records show in this utility’s water: nitrate, arsenic and other regulated chemicals; lead and copper; and violations since 2016, with the certification that handles each result.
- Serves
- 999 people
- Connections
- 333
- Water source
- Groundwater
- Based in
- Gary, TX
- County
- Panola
- Owner
- Local government
The ZIP code it serves
The short answer
2 results are above EPA’s legal limit. The worst: Total trihalomethanes (TTHM), above the legal limit. 9 health-based violations since 2016.
What handles itWhat was found
Lead and copper: EPA SDWIS monitoring periods ending 1994 to 2020.
Total trihalomethanes (TTHM), haloacetic acids (HAA5), fluoride, nitrate, arsenic, chromium (total) and uranium: Texas’s own results, samples taken from Sept. 22, 2020 to Sept. 9, 2026, with EPA’s 2012 to 2019 file for earlier years.
Above the legal limit2
Total trihalomethanes (TTHM)
Forms or is added in treatment
190ppb
Highest yearly average, 2020 to 2026
2026 average: 68.1 ppb
Averaged by year, the highest was 190 ppb, in 2024, about 2.4 times EPA’s legal limit of 80 ppb. Its highest single sample was 211 ppb. In 2026, the latest year on file, its three samples averaged 68.1 ppb. EPA recorded violations for total trihalomethanes (TTHM) at this utility in 2024 and 2025. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 15.2 ppb, in 2014.
What handles it
- NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
- NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”
Copper
Comes from pipes, often your own
1.4ppm
90th percentile, 2020
In the latest period, 9 in 10 homes sampled were at or below 1.4 ppm, above EPA’s action level of 1.3 ppm.
What handles it
- NSF/ANSI 53 look for “Copper Reduction”
- NSF/ANSI 58 look for “Copper Reduction”
Below EPA’s limits3
Haloacetic acids (HAA5)
Forms or is added in treatment
20.9ppb
Highest yearly average, 2020 to 2026
2026 average: 18.6 ppb
Averaged by year, the highest was 20.9 ppb, in 2024, below EPA’s legal limit of 60 ppb. Its highest single sample was 44.6 ppb. In 2026, the latest year on file, its three samples averaged 18.6 ppb. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 15.2 ppb, in 2018.
What handles it
No certification claim covers this compound yet.
Fluoride
Forms or is added in treatment
0.83ppm
Highest yearly average, 2021 to 2024
2024, one sample: 0.82 ppm
Averaged by year, the highest was 0.83 ppm, in 2021, below EPA’s legal limit of 4.0 ppm. In 2024, the latest year on file, its one sample was 0.82 ppm. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 0.88 ppm, in 2012.
What handles it
- NSF/ANSI 58 look for “Fluoride Reduction”
- NSF/ANSI 53 look for “Fluoride”
Nitrate
Comes from the source
0.37ppm
Highest sample; found in 7 of 7
2026, one sample: 0.16 ppm
The highest sample, in 2022, was 0.37 ppm, below EPA’s legal limit of 10 ppm. In 2026, the latest year on file, its one sample was 0.16 ppm. Earlier, from 2012 to 2019, EPA’s file shows a highest sample of 0.16 ppm, in 2016.
What handles it
- NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
- NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”
4 compounds tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
- Arsenic
- Chromium (total)
- Lead
- Uranium
What handles it
A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box. Wording varies a little: NSF writes “Lead Reduction,” WQA just “Lead.”
- NSF/ANSI 53
Claims: Trihalomethanes (TTHM) Reduction, Copper Reduction
For: Total trihalomethanes (TTHM), Copper
Other certifiers’ wording: VOC Reduction
- NSF/ANSI 58
Claims: Trihalomethanes (TTHM) Reduction, Copper Reduction
For: Total trihalomethanes (TTHM), Copper
At the tap, or for the whole house?
Lead and copper usually come from pipes and fixtures inside or near your home. A whole-house system sits where water enters, so it cannot catch what your own plumbing adds after it. For those, the filter that counts is the one at the tap. How whole-house systems compare.
Filters with those claims on a certifier’s listing
Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money
Aquasana SmartFlow Reverse Osmosis (AQ-SFRO2)
Under-sink reverse osmosis
- WQA listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 58NSF/ANSI 401checked Oct. 9, 2026
Certified for: Total trihalomethanes (TTHM), Copper
Brondell Capella RC250 Reverse Osmosis System
Under-sink reverse osmosis
- WQA listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 58NSF/ANSI 401checked Oct. 9, 2026
Certified for: Total trihalomethanes (TTHM), Copper
Countertop reverse osmosis
- IAPMO listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 58NSF/ANSI 401checked Oct. 4, 2026
Certified for: Total trihalomethanes (TTHM), Copper
Aquasana Clean Water Machine (AQ-CWM2)
Countertop
- WQA listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 401checked Oct. 9, 2026
Certified for: Total trihalomethanes (TTHM)
Brita Hub Countertop Water Filter System (87340)
Countertop
- WQA listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 401checked Oct. 9, 2026
- IAPMO listing:NSF/ANSI 53checked Oct. 9, 2026
Certified for: Total trihalomethanes (TTHM)
Violations since 2016
| Contaminant or rule | Type | Period | Measured | Status |
|---|---|---|---|---|
| TTHM | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | April 1, 2025 to June 30, 2025 | 0.1 MG/L | Resolved |
| TTHM | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | Jan. 1, 2025 to March 31, 2025 | 0.1 MG/L | Resolved |
| Lead and Copper Rule | Required information about lead was not given to customers.EPA: Public Education | Dec. 1, 2024 | — | Resolved |
| TTHM | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | Oct. 1, 2024 to Dec. 31, 2024 | 0.095 MG/L | Resolved |
| Lead and Copper Rule | A required study or plan for corrosion control was not done on time.EPA: OCCT/SOWT Study/Recommendation | Jan. 1, 2021 | — | Resolved |
| Lead and Copper Rule | A required study or plan for corrosion control was not done on time.EPA: OCCT/SOWT Study/Recommendation | Dec. 31, 2020 | — | Resolved |
| Lead and Copper Rule | A required study or plan for corrosion control was not done on time.EPA: OCCT/SOWT Study/Recommendation | Oct. 1, 2016 | — | Resolved |
| Lead and Copper Rule | A required study or plan for corrosion control was not done on time.EPA: OCCT/SOWT Study/Recommendation | April 1, 2016 | — | Resolved |
| Lead and Copper Rule | A required study or plan for corrosion control was not done on time.EPA: OCCT/SOWT Study/Recommendation | March 31, 2016 | — | Resolved |
| Health-based violations only. Resolved and archived mean the utility returned to compliance or the state closed the record. 68 monitoring or reporting violations not shown. | ||||
What this report can’t tell you
Everything else. Total trihalomethanes (TTHM), haloacetic acids (HAA5), fluoride, nitrate, arsenic, chromium (total) and uranium results here are Texas’s own from 2020 on, with EPA’s national file for 2012 to 2019. Murvaul WSC’s own annual report, which it must send you every year, has the contaminants this page does not show.
Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.
What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.
Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; Texas’s results run from Sept. 22, 2020 to Sept. 9, 2026.
Testing your own tap
The 3 labs Texas certifies closest to the area Murvaul WSC serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.
Southern Petroleum Laboratories (SPL), Inc. (FKA Ana-Lab Corporation)
Kilgore, TX · about 39 miles
Certified for bacteria, lead and copper
Eastex Environmental Lab, Inc.-Nacogdoches
Nacogdoches, TX · about 42 miles
Certified for bacteria
Environmental Monitoring Lab
Winona, TX · about 54 miles
Certified for bacteria
Texas Well Owner Network, Texas A&M AgriLife Extension: Well Informed screening events, where well owners bring in water samples to be screened for common contaminants, followed by an hour-long session explaining the results. Upcoming events are on the network's calendar. Trainings, Texas Well Owner Network.
All 80 certified labs for TexasSources
- EPA UCMR 5 occurrence data, file of Oct. 15, 2026
- EPA SDWA bulk download (SDWIS federal data), 2026 Q3
- Texas Commission on Environmental Quality, Texas Drinking Water Viewer, results from Jan. 7, 2020 to Oct. 6, 2026, read Oct. 16, 2026
- EPA Six-Year Review 4 compliance monitoring data, 2012 to 2019, file of Feb. 5, 2024
- Certified labs: TCEQ, drinking water laboratories approved for public water system samples, read Oct. 10, 2026; distances from the Census 2020 ZIP code tabulation area gazetteer
- Limits and goals: each contaminant’s page, with its EPA source.
- How this page is built: methodology.
PWSID TX1830010. Rebuilt from EPA data on Oct. 18, 2026.
What to do next
- Read up on the 2 results above a lineWhat each one does to health, where it comes from, and the certification claim that addresses it.Start with Total trihalomethanes (TTHM)
- Get the utility’s own reportMurvaul WSC must send you a water quality report every year. It covers contaminants this page does not show.How to read it
- Test your own tap for leadYour service line, solder and fixtures decide the lead at your faucet, not the utility’s average.Lead in your water: what to do
- Compare certified filtersWhat the filters certified for these results cost over five years, cartridges included.Compare five-year costs