What EPA’s and Texas’s records show in this utility’s water: nitrate, arsenic and other regulated chemicals; lead and copper; and violations since 2016, with the certification that handles each result.

Serves
2,817 people
Connections
939
Water source
Surface water bought from another system
Based in
Houston, TX
County
Harris
Owner
Local government
The ZIP code it serves

77084

The short answer

2 results are above the health goal. The worst: Arsenic, above the health goal. 10 health-based violations since 2016.

What handles it

What was found

Arsenic, uranium, haloacetic acids (HAA5), total trihalomethanes (TTHM), nitrate, fluoride and chromium (total): Texas’s own results, samples taken from Feb. 24, 2020 to July 28, 2026, with EPA’s 2012 to 2019 file for earlier years.

Above the health goal2

Arsenic

Comes from the source

Above the health goal

5.8ppb

Highest yearly average, 2021 to 2026

2026: not found

Averaged by year, the highest was 5.8 ppb, in 2021: below EPA’s legal limit of 10 ppb, but above its health goal of zero. In 2026, the latest year on file, it wasn’t found in its one sample. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 7.2 ppb, in 2018.

What handles it

  • NSF/ANSI 58 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
  • NSF/ANSI 53 look for “Arsenic (Pentavalent)<=50 ppb Reduction”

Uranium

Comes from the source

Above the health goal

1.5ppb

Highest yearly average, 2020 to 2026

Averaged by year, the highest was 1.5 ppb, in 2026: below EPA’s legal limit of 30 ppb, but above its health goal of zero. Its highest single sample was 4.5 ppb. That was also the latest year on file. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 1.6 ppb, in 2014.

What handles it

Below EPA’s limits4

Haloacetic acids (HAA5)

Forms or is added in treatment

Below EPA’s limits

23.2ppb

Highest yearly average, 2020 to 2026

2026 average: 0.43 ppb

Averaged by year, the highest was 23.2 ppb, in 2024, below EPA’s legal limit of 60 ppb. Its highest single sample was 67.3 ppb. In 2026, the latest year on file, its three samples averaged 0.43 ppb. EPA recorded no violation for haloacetic acids (HAA5) at this utility since 2020. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 1.0 ppb, in 2016.

What handles it

No certification claim covers this compound yet.

Total trihalomethanes (TTHM)

Forms or is added in treatment

Below EPA’s limits

15.8ppb

Highest yearly average, 2020 to 2026

2026 average: 1.5 ppb

Averaged by year, the highest was 15.8 ppb, in 2023, below EPA’s legal limit of 80 ppb. Its highest single sample was 37.9 ppb. In 2026, the latest year on file, its three samples averaged 1.5 ppb. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 5.3 ppb, in 2012.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”

Nitrate

Comes from the source

Below EPA’s limits

1.0ppm

Highest sample; found in 16 of 24

2026 average: 0.28 ppm

The highest sample, in 2024, was 1.0 ppm, below EPA’s legal limit of 10 ppm. In 2026, the latest year on file, its five samples averaged 0.28 ppm. Earlier, from 2012 to 2019, EPA’s file shows a highest sample of 0.38 ppm, in 2018.

What handles it

  • NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
  • NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”

Fluoride

Forms or is added in treatment

Below EPA’s limits

0.24ppm

Highest yearly average, 2020 to 2026

2026: not found

Averaged by year, the highest was 0.24 ppm, in 2024, below EPA’s legal limit of 4.0 ppm. In 2026, the latest year on file, it wasn’t found in any of its two samples. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 0.25 ppm, in 2012.

What handles it

2 compounds tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
  • Chromium (total)
  • Lead

What handles it

A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box. Wording varies a little: NSF writes “Lead Reduction,” WQA just “Lead.”

  • NSF/ANSI 53

    Claim: Arsenic (Pentavalent)<=50 ppb Reduction

    For: Arsenic

    Other certifiers’ wording: Arsenic (III) (50 ppb influent level)

  • NSF/ANSI 58

    Claims: Arsenic (Pentavalent)<=50 ppb Reduction, Uranium

    For: Arsenic, Uranium

    Other certifiers’ wording: Arsenic (Pentavalent)<=300 ppb Reduction; Arsenic (V) (300 ppb influent level)

At the tap, or for the whole house?

These come with the water itself, so a whole-house system certified for the same claims treats every tap and shower. A filter at the tap treats drinking water for much less. How whole-house systems compare.

Filters with those claims on a certifier’s listing

Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money

Compare five-year costs

The best reverse osmosis systems, ranked

Violations since 2016

Contaminant or ruleTypePeriodMeasuredStatus
Gross alpha radiation (excluding radon and uranium)The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJuly 1, 2019 to Sept. 30, 201916 PCI/LResolved
Gross alpha radiation (excluding radon and uranium)The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageApril 1, 2019 to June 30, 201917 PCI/LResolved
Gross alpha radiation (excluding radon and uranium)The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJan. 1, 2019 to March 31, 201917 PCI/LResolved
Gross alpha radiation (excluding radon and uranium)The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageOct. 1, 2018 to Dec. 31, 201818 PCI/LResolved
Gross alpha radiation (excluding radon and uranium)The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJuly 1, 2018 to Sept. 30, 201818 PCI/LResolved
Gross alpha radiation (excluding radon and uranium)The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageApril 1, 2018 to June 30, 201817 PCI/LResolved
Gross alpha radiation (excluding radon and uranium)The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJan. 1, 2018 to March 31, 201817 PCI/LResolved
Gross alpha radiation (excluding radon and uranium)The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageOct. 1, 2016 to Dec. 31, 201616 PCI/LResolved
Gross alpha radiation (excluding radon and uranium)The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJuly 1, 2016 to Sept. 30, 201617 PCI/LResolved
Gross alpha radiation (excluding radon and uranium)The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageApril 1, 2016 to June 30, 201616 PCI/LResolved
Health-based violations only. Resolved and archived mean the utility returned to compliance or the state closed the record. 8 monitoring or reporting violations not shown.

What this report can’t tell you

  • Everything else. Arsenic, uranium, haloacetic acids (HAA5), total trihalomethanes (TTHM), nitrate, fluoride and chromium (total) results here are Texas’s own from 2020 on, with EPA’s national file for 2012 to 2019. Morton Road MUD’s own annual report, which it must send you every year, has the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; Texas’s results run from Feb. 24, 2020 to July 28, 2026.

Testing your own tap

Morton Road MUD’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab Texas certifies.

The 3 labs Texas certifies closest to the area Morton Road MUD serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

  • R&C Joy, Inc.

    Katy, TX · about 4 miles

    Certified for bacteria

    (281) 858-5988

  • Eurofins EMLab P&K – Houston

    Houston, TX · about 5 miles

    Certified for bacteria

    (281) 940-2580

  • ALS Laboratory Group, Environmental Services Division – Houston, Texas

    Houston, TX · about 12 miles

    Certified for lead and copper

    (281) 530-5656

Texas Well Owner Network, Texas A&M AgriLife Extension: Well Informed screening events, where well owners bring in water samples to be screened for common contaminants, followed by an hour-long session explaining the results. Upcoming events are on the network's calendar. Trainings, Texas Well Owner Network.

All 80 certified labs for Texas