Skip to content
TapBuff

Little Oak Forest Subdivision

What EPA’s and Texas’s records show in this utility’s water: nitrate, arsenic and other regulated chemicals; lead and copper; and violations since 2016, with the certification that handles each result.

Serves
189 people
Connections
63
Water source
Groundwater
Based in
Cypress, TX
County
Burleson
Owner
Private
The ZIP code it serves

77879

The short answer

2 results are above the health goal. The worst: Arsenic, above the health goal. 6 health-based violations since 2016.

What handles it

What was found

Lead and copper: EPA SDWIS monitoring periods ending 2023.

Arsenic, total trihalomethanes (TTHM), haloacetic acids (HAA5), chromium (total), fluoride, nitrate and uranium: Texas’s own results, samples taken from Feb. 27, 2020 to Aug. 6, 2026, with EPA’s 2012 to 2019 file for earlier years.

Above the health goal2

Arsenic

Comes from the source

Above the health goal

2.4ppb

Highest yearly average, 2022 to 2025

2025: not found

Averaged by year, the highest was 2.4 ppb, in 2022: below EPA’s legal limit of 10 ppb, but above its health goal of zero. In 2025, the latest year on file, it wasn’t found in its one sample.

What handles it

  • NSF/ANSI 58 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
  • NSF/ANSI 53 look for “Arsenic (Pentavalent)<=50 ppb Reduction”

Lead

Comes from pipes, often your own

Above the health goal

0.4ppb

90th percentile, 2021 to 2023

In the latest period, 9 in 10 homes sampled were at or below 0.4 ppb, below EPA’s action level of 15 ppb. The action level drops to 10 ppb on Nov. 1, 2027. EPA’s health goal for lead is zero.

What handles it

Below EPA’s limits4

Total trihalomethanes (TTHM)

Forms or is added in treatment

Below EPA’s limits

68.3ppb

Highest yearly average, 2020 to 2026

2026 average: 33.2 ppb

Averaged by year, the highest was 68.3 ppb, in 2022, below EPA’s legal limit of 80 ppb. Its highest single sample was 106 ppb. In 2026, the latest year on file, its three samples averaged 33.2 ppb. EPA recorded no violation for total trihalomethanes (TTHM) at this utility since 2020. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 90.2 ppb, in 2018, and EPA recorded violations in 2017 and 2018.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”

Haloacetic acids (HAA5)

Forms or is added in treatment

Below EPA’s limits

10.3ppb

Highest yearly average, 2020 to 2026

2026 average: 5.8 ppb

Averaged by year, the highest was 10.3 ppb, in 2022, below EPA’s legal limit of 60 ppb. Its highest single sample was 16.2 ppb. In 2026, the latest year on file, its three samples averaged 5.8 ppb. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 10.2 ppb, in 2018.

What handles it

No certification claim covers this compound yet.

Chromium (total)

Comes from the source

Below EPA’s limits

13.7ppb

Highest yearly average, 2022 to 2025

2025: not found

Averaged by year, the highest was 13.7 ppb, in 2022, below EPA’s legal limit of 100 ppb. In 2025, the latest year on file, it wasn’t found in its one sample. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 1.6 ppb, in 2013.

What handles it

Fluoride

Forms or is added in treatment

Below EPA’s limits

0.25ppm

Highest yearly average, 2022 to 2025

2025, one sample: 0.24 ppm

Averaged by year, the highest was 0.25 ppm, in 2022, below EPA’s legal limit of 4.0 ppm. In 2025, the latest year on file, its one sample was 0.24 ppm. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 0.25 ppm, in 2016.

What handles it

2 compounds tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
  • Nitrate
  • Uranium

What handles it

A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box. Wording varies a little: NSF writes “Lead Reduction,” WQA just “Lead.”

  • NSF/ANSI 53

    Claims: Arsenic (Pentavalent)<=50 ppb Reduction, Lead Reduction

    For: Arsenic, Lead

    Other certifiers’ wording: Arsenic (III) (50 ppb influent level)

  • NSF/ANSI 58

    Claims: Arsenic (Pentavalent)<=50 ppb Reduction, Lead Reduction

    For: Arsenic, Lead

    Other certifiers’ wording: Arsenic (Pentavalent)<=300 ppb Reduction; Arsenic (V) (300 ppb influent level)

At the tap, or for the whole house?

Lead and copper usually come from pipes and fixtures inside or near your home. A whole-house system sits where water enters, so it cannot catch what your own plumbing adds after it. For those, the filter that counts is the one at the tap. How whole-house systems compare.

Filters with those claims on a certifier’s listing

Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money

Compare five-year costs

The best reverse osmosis systems, ranked

The best water filters for lead, ranked

Violations since 2016

Contaminant or ruleTypePeriodMeasuredStatus
TTHMThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageOct. 1, 2018 to Dec. 31, 20180.09 MG/LResolved
TTHMThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJuly 1, 2018 to Sept. 30, 20180.096 MG/LResolved
TTHMThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageApril 1, 2018 to June 30, 20180.092 MG/LResolved
TTHMThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJan. 1, 2018 to March 31, 20180.1 MG/LResolved
TTHMThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageOct. 1, 2017 to Dec. 31, 20170.084 MG/LResolved
TTHMThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJuly 1, 2017 to Sept. 30, 20170.085 MG/LResolved
Health-based violations only. Resolved and archived mean the utility returned to compliance or the state closed the record. 3 monitoring or reporting violations not shown.

What this report can’t tell you

  • Everything else. Arsenic, total trihalomethanes (TTHM), haloacetic acids (HAA5), chromium (total), fluoride, nitrate and uranium results here are Texas’s own from 2020 on, with EPA’s national file for 2012 to 2019. Little Oak Forest Subdivision’s own annual report, which it must send you every year, has the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; Texas’s results run from Feb. 27, 2020 to Aug. 6, 2026.

Testing your own tap

Little Oak Forest Subdivision’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab Texas certifies.

The 3 labs Texas certifies closest to the area Little Oak Forest Subdivision serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

  • Aqua-Tech Laboratories, Inc.

    Bryan, TX · about 19 miles

    Certified for bacteria, lead and copper

    (979) 778-3707

  • R&C Joy, Inc.

    Katy, TX · about 60 miles

    Certified for bacteria

    (281) 858-5988

  • Chaparral Laboratories, Inc.

    Huntsville, TX · about 63 miles

    Certified for bacteria, lead and copper

    (936) 291-1881

Texas Well Owner Network, Texas A&M AgriLife Extension: Well Informed screening events, where well owners bring in water samples to be screened for common contaminants, followed by an hour-long session explaining the results. Upcoming events are on the network's calendar. Trainings, Texas Well Owner Network.

All 80 certified labs for Texas

Sources

PWSID TX0260037. Rebuilt from EPA data on Oct. 18, 2026.