Knob Hill Water System Denton
What EPA’s and Texas’s records show in this utility’s water: nitrate, arsenic and other regulated chemicals; lead and copper; and violations since 2016, with the certification that handles each result.
- Serves
- 234 people
- Connections
- 78
- Water source
- Groundwater
- Based in
- Little Elm, TX
- County
- Denton
- Owner
- Private
The ZIP code it serves
The short answer
Nothing in EPA’s and Texas’s records for this utility is above a health goal. That covers nitrate, arsenic and other regulated chemicals, plus lead and copper, not everything. 1 health-based violation since 2016.
What was found
Fluoride, total trihalomethanes (TTHM), nitrate, chromium (total), arsenic, haloacetic acids (HAA5) and uranium: Texas’s own results, samples taken from March 19, 2020 to Feb. 5, 2026, with EPA’s 2012 to 2019 file for earlier years.
Below EPA’s limits4
Fluoride
Forms or is added in treatment
0.26ppm
Highest yearly average, 2022 to 2025
2025 average: 0.17 ppm
Averaged by year, the highest was 0.26 ppm, in 2022, below EPA’s legal limit of 4.0 ppm. Its highest single sample was 0.36 ppm. In 2025, the latest year on file, its two samples averaged 0.17 ppm. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 0.29 ppm, in 2019.
What handles it
- NSF/ANSI 58 look for “Fluoride Reduction”
- NSF/ANSI 53 look for “Fluoride”
Total trihalomethanes (TTHM)
Forms or is added in treatment
4.8ppb
Highest yearly average, 2022 to 2025
2025: not found
Averaged by year, the highest was 4.8 ppb, in 2022, below EPA’s legal limit of 80 ppb. In 2025, the latest year on file, it wasn’t found in its one sample. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 4.3 ppb, in 2019.
What handles it
- NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
- NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”
Nitrate
Comes from the source
0.39ppm
Highest sample; found in 12 of 14
2026 average: 0.013 ppm
The highest sample, in 2020, was 0.39 ppm, below EPA’s legal limit of 10 ppm. In 2026, the latest year on file, its two samples averaged 0.013 ppm. Earlier, from 2012 to 2019, EPA’s file shows a highest sample of 0.51 ppm, in 2017.
What handles it
- NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
- NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”
Chromium (total)
Comes from the source
1.5ppb
Highest yearly average, 2021 to 2024
2024: not found
Averaged by year, the highest was 1.5 ppb, in 2021, below EPA’s legal limit of 100 ppb. Its highest single sample was 3.0 ppb. In 2024, the latest year on file, it wasn’t found in any of its two samples.
What handles it
- NSF/ANSI 58 look for “Chromium (Hexavalent) Reduction”
- NSF/ANSI 53 look for “Chromium Reduction”
4 compounds tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
- Arsenic
- Haloacetic acids (HAA5)
- Lead
- Uranium
Violations since 2016
| Contaminant or rule | Type | Period | Measured | Status |
|---|---|---|---|---|
| Lead and Copper Rule Revisions | The required inventory of lead service lines was not completed or submitted on time.EPA: LSL Inventory | Oct. 17, 2024 | — | Unaddressed |
| Health-based violations only. Resolved and archived mean the utility returned to compliance or the state closed the record. 11 monitoring or reporting violations not shown. | ||||
What this report can’t tell you
Everything else. Fluoride, total trihalomethanes (TTHM), nitrate, chromium (total), arsenic, haloacetic acids (HAA5) and uranium results here are Texas’s own from 2020 on, with EPA’s national file for 2012 to 2019. Knob Hill Water System Denton’s own annual report, which it must send you every year, has the contaminants this page does not show.
Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.
What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.
Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; Texas’s results run from March 19, 2020 to Feb. 5, 2026.
Testing your own tap
The 3 labs Texas certifies closest to the area Knob Hill Water System Denton serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.
Pace Analytical Services, LLC -Dallas TX
Allen, TX · about 15 miles
Certified for bacteria
Southern Petroleum Laboratories, Inc. - Plano
Plano, TX · about 19 miles
Certified for bacteria, lead and copper
Eurofins Xenco, LLC -Dallas
Dallas, TX · about 21 miles
Certified for bacteria
Texas Well Owner Network, Texas A&M AgriLife Extension: Well Informed screening events, where well owners bring in water samples to be screened for common contaminants, followed by an hour-long session explaining the results. Upcoming events are on the network's calendar. Trainings, Texas Well Owner Network.
All 80 certified labs for TexasSources
- EPA UCMR 5 occurrence data, file of Oct. 15, 2026
- EPA SDWA bulk download (SDWIS federal data), 2026 Q3
- Texas Commission on Environmental Quality, Texas Drinking Water Viewer, results from Jan. 7, 2020 to Oct. 6, 2026, read Oct. 16, 2026
- EPA Six-Year Review 4 compliance monitoring data, 2012 to 2019, file of Feb. 5, 2024
- Certified labs: TCEQ, drinking water laboratories approved for public water system samples, read Oct. 10, 2026; distances from the Census 2020 ZIP code tabulation area gazetteer
- Limits and goals: each contaminant’s page, with its EPA source.
- How this page is built: methodology.
PWSID TX0610068. Rebuilt from EPA data on Oct. 18, 2026.
What to do next
- Nothing here is above a health goalIn EPA’s and Texas’s records for this utility. They don’t cover everything, which is why the next step matters.Every contaminant TapBuff tracks
- Get the utility’s own reportKnob Hill Water System Denton must send you a water quality report every year. It covers contaminants this page does not show.How to read it
- Test your own tap for leadYour service line, solder and fixtures decide the lead at your faucet, not the utility’s average.Lead in your water: what to do
- Decide if you want a filter at allA filter for taste or chlorine is a preference, not a need. The standards say what each kind can do.NSF/ANSI standards, decoded