Skip to content
TapBuff

Kendall County WCID 3a

What EPA’s and Texas’s records show in this utility’s water: nitrate, arsenic and other regulated chemicals; lead and copper; and violations since 2016, with the certification that handles each result.

Serves
45 people
Connections
15
Water source
Surface water bought from another system
Based in
Houston, TX
County
Kendall
Owner
Local government

The short answer

1 result is above the health goal. The worst: Lead, above the health goal. No health-based violations on file since 2016.

What handles it

What was found

Lead and copper: EPA SDWIS monitoring periods ending 2025 to 2026.

Total trihalomethanes (TTHM), haloacetic acids (HAA5) and nitrate: Texas’s own results, samples taken from Sept. 26, 2024 to Sept. 16, 2026.

Above the health goal1

Lead

Comes from pipes, often your own

Above the health goal

0.21ppb

90th percentile, 2026

In the latest period, 9 in 10 homes sampled were at or below 0.21 ppb, below EPA’s action level of 15 ppb. The action level drops to 10 ppb on Nov. 1, 2027. EPA’s health goal for lead is zero.

What handles it

Below EPA’s limits3

Total trihalomethanes (TTHM)

Forms or is added in treatment

Below EPA’s limits

71.2ppb

Highest yearly average, 2024 to 2025

2025, one sample: 54 ppb

Averaged by year, the highest was 71.2 ppb, in 2024, below EPA’s legal limit of 80 ppb. In 2025, the latest year on file, its one sample was 54 ppb.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”

Haloacetic acids (HAA5)

Forms or is added in treatment

Below EPA’s limits

12.9ppb

Highest yearly average, 2024 to 2025

Averaged by year, the highest was 12.9 ppb, in 2025, below EPA’s legal limit of 60 ppb. That was also the latest year on file.

What handles it

No certification claim covers this compound yet.

Nitrate

Comes from the source

Below EPA’s limits

0.46ppm

Highest sample; found in 5 of 9

2026 average: 0.24 ppm

The highest sample, in 2026, was 0.46 ppm, below EPA’s legal limit of 10 ppm. That was also the latest year on file, and its three samples averaged 0.24 ppm.

What handles it

  • NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
  • NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”

What handles it

A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box. Wording varies a little: NSF writes “Lead Reduction,” WQA just “Lead.”

At the tap, or for the whole house?

Lead and copper usually come from pipes and fixtures inside or near your home. A whole-house system sits where water enters, so it cannot catch what your own plumbing adds after it. For those, the filter that counts is the one at the tap. How whole-house systems compare.

Filters with those claims on a certifier’s listing

Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money

Compare five-year costs

The best water filters for lead, ranked

Violations since 2016

No health-based violations on file with EPA since 2016. There are 2 monitoring or reporting violations: a sample missed, late or not reported.

What this report can’t tell you

  • Everything else. Total trihalomethanes (TTHM), haloacetic acids (HAA5) and nitrate results here are Texas’s own from 2024 on, with EPA’s national file for 2012 to 2019. Kendall County WCID 3a’s own annual report, which it must send you every year, has the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; Texas’s results run from Sept. 26, 2024 to Sept. 16, 2026.

Testing your own tap

Kendall County WCID 3a’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab Texas certifies.

No lab Texas certifies is within 75 miles of the area Kendall County WCID 3a serves on the state’s list. Some take samples by mail; the state’s page lists them all.

Texas Well Owner Network, Texas A&M AgriLife Extension: Well Informed screening events, where well owners bring in water samples to be screened for common contaminants, followed by an hour-long session explaining the results. Upcoming events are on the network's calendar. Trainings, Texas Well Owner Network.

All 80 certified labs for Texas

Sources

PWSID TX1300082. Rebuilt from EPA data on Oct. 18, 2026.