Holly Springs WSC West Meter
What EPA’s and Texas’s records show in this utility’s water: nitrate, arsenic and other regulated chemicals; lead and copper; and violations since 2016, with the certification that handles each result.
- Serves
- 312 people
- Connections
- 104
- Water source
- Surface water bought from another system
- Based in
- Daingerfield, TX
- County
- Cass
- Owner
- Local government
The short answer
1 result is above EPA’s legal limit. The worst: Haloacetic acids (HAA5), above the legal limit. 2 health-based violations since 2016.
What was found
Haloacetic acids (HAA5), total trihalomethanes (TTHM) and nitrate: Texas’s own results, samples taken from Feb. 26, 2020 to Sept. 2, 2026, with EPA’s 2012 to 2019 file for earlier years.
Above the legal limit1
Haloacetic acids (HAA5)
Forms or is added in treatment
62.4ppb
Highest yearly average, 2020 to 2026
2026 average: 23.4 ppb
Averaged by year, the highest was 62.4 ppb, in 2021, above EPA’s legal limit of 60 ppb. Its highest single sample was 89.2 ppb. In 2026, the latest year on file, its three samples averaged 23.4 ppb. EPA recorded a violation for haloacetic acids (HAA5) at this utility in 2021. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 78.8 ppb, in 2016.
What handles it
No certification claim covers this compound yet.
Below EPA’s limits2
Total trihalomethanes (TTHM)
Forms or is added in treatment
45.9ppb
Highest yearly average, 2020 to 2026
2026 average: 21.2 ppb
Averaged by year, the highest was 45.9 ppb, in 2021, below EPA’s legal limit of 80 ppb. Its highest single sample was 101 ppb. In 2026, the latest year on file, its three samples averaged 21.2 ppb. EPA recorded no violation for total trihalomethanes (TTHM) at this utility since 2020. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 54.6 ppb, in 2016.
What handles it
- NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
- NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”
Nitrate
Comes from the source
0.48ppm
Highest sample; found in 7 of 7
2026, one sample: 0.21 ppm
The highest sample, in 2024, was 0.48 ppm, below EPA’s legal limit of 10 ppm. In 2026, the latest year on file, its one sample was 0.21 ppm.
What handles it
- NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
- NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”
One compound tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
- Lead
Violations since 2016
| Contaminant or rule | Type | Period | Measured | Status |
|---|---|---|---|---|
| Total Haloacetic Acids (HAA5) | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | Oct. 1, 2021 to Dec. 31, 2021 | 0.062 MG/L | Resolved |
| Total Haloacetic Acids (HAA5) | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | July 1, 2021 to Sept. 30, 2021 | 0.061 MG/L | Resolved |
| Health-based violations only. Resolved and archived mean the utility returned to compliance or the state closed the record. 1 monitoring or reporting violation not shown. | ||||
What this report can’t tell you
Everything else. Haloacetic acids (HAA5), total trihalomethanes (TTHM) and nitrate results here are Texas’s own from 2020 on, with EPA’s national file for 2012 to 2019. Holly Springs WSC West Meter’s own annual report, which it must send you every year, has the contaminants this page does not show.
Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.
What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.
Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; Texas’s results run from Feb. 26, 2020 to Sept. 2, 2026.
Testing your own tap
The 3 labs Texas certifies closest to the area Holly Springs WSC West Meter serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.
Southern Petroleum Laboratories (SPL), Inc. (FKA Ana-Lab Corporation)
Kilgore, TX · about 45 miles
Certified for bacteria, lead and copper
Environmental Monitoring Lab
Winona, TX · about 46 miles
Certified for bacteria
Northeast Texas Public Health District Laboratory
Tyler, TX · about 59 miles
Certified for bacteria
Texas Well Owner Network, Texas A&M AgriLife Extension: Well Informed screening events, where well owners bring in water samples to be screened for common contaminants, followed by an hour-long session explaining the results. Upcoming events are on the network's calendar. Trainings, Texas Well Owner Network.
All 80 certified labs for TexasSources
- EPA UCMR 5 occurrence data, file of Oct. 15, 2026
- EPA SDWA bulk download (SDWIS federal data), 2026 Q3
- Texas Commission on Environmental Quality, Texas Drinking Water Viewer, results from Jan. 7, 2020 to Oct. 6, 2026, read Oct. 16, 2026
- EPA Six-Year Review 4 compliance monitoring data, 2012 to 2019, file of Feb. 5, 2024
- Certified labs: TCEQ, drinking water laboratories approved for public water system samples, read Oct. 10, 2026; distances from the Census 2020 ZIP code tabulation area gazetteer
- Limits and goals: each contaminant’s page, with its EPA source.
- How this page is built: methodology.
PWSID TX0340067. Rebuilt from EPA data on Oct. 18, 2026.
What to do next
- Read up on Haloacetic acids (HAA5)What each one does to health, where it comes from, and the certification claim that addresses it.About Haloacetic acids (HAA5)
- Get the utility’s own reportHolly Springs WSC West Meter must send you a water quality report every year. It covers contaminants this page does not show.How to read it
- Test your own tap for leadYour service line, solder and fixtures decide the lead at your faucet, not the utility’s average.Lead in your water: what to do
- Decide if you want a filter at allA filter for taste or chlorine is a preference, not a need. The standards say what each kind can do.NSF/ANSI standards, decoded