Harris County MUD 449
EPA’s and Texas’s records have results for 8 contaminants in its water; 3 were found.
In the name, MUD means municipal utility district.
Serves 7,179 people · Groundwater · Houston, TX
- Serves
- 7,179 people
- Connections
- 2,434
- Water source
- Groundwater
- Based in
- Houston, TX
- County
- Harris
- Owner
- Local government
The ZIP code it serves
The short answer
None of the results here is above a limit in force today. That covers nitrate, arsenic and other regulated chemicals, plus lead and copper, not everything. No health-based violations on file since 2016.
What was found
Where these results come from, and when
Arsenic, fluoride, total trihalomethanes (TTHM), chromium (total), haloacetic acids (HAA5), nitrate and uranium: Texas’s own results, samples taken from Aug. 7, 2020 to Jan. 22, 2026, with EPA’s 2012 to 2019 file for earlier years.
What the lines mean
- Legal limit (MCL):
- Enforceable. The most a utility may deliver.
- Health goal (MCLG):
- Not enforceable. The level with no expected risk, with a margin of safety.
Below EPA’s limits, 3 results
Arsenic has a health goal of zero: the level with no known or expected risk. Any amount found is above it, but the goal isn’t a limit.
- Legal limit (MCL):
- Enforceable. The most a utility may deliver.
Arsenic, Legal limit 10 ppb · health goal zero; highest yearly average 6.6 ppb
Highest yearly average, 2020 to 2026 · Comes from the source
Averaged by year, the highest was 6.6 ppb, in 2026, below EPA’s legal limit of 10 ppb. Its health goal is zero, so any amount found is above it; the goal isn’t a limit. That was also the latest year on file.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest yearly average of 8.6 ppb, in 2017.
What handles it
- NSF/ANSI 58 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
- NSF/ANSI 53 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
Fluoride, Legal limit 4.0 ppm; highest yearly average 0.55 ppm
Highest yearly average, 2021 to 2024 · 2024 average: 0.51 ppm · Forms or is added in treatment
Averaged by year, the highest was 0.55 ppm, in 2021, below EPA’s legal limit of 4.0 ppm. Its highest single sample was 0.62 ppm. In 2024, the latest year on file, its two samples averaged below the limit.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest yearly average of 0.68 ppm, in 2015.
What handles it
- NSF/ANSI 58 look for “Fluoride Reduction”
- NSF/ANSI 53 look for “Fluoride”
Total trihalomethanes (TTHM), Legal limit 80 ppb; highest yearly average 2.3 ppb
Highest yearly average, 2021 to 2024 · 2024: not found · Forms or is added in treatment
Averaged by year, the highest was 2.3 ppb, in 2021, below EPA’s legal limit of 80 ppb. In 2024, the latest year on file, it wasn’t found in its one sample.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest yearly average of 2.6 ppb, in 2015.
What handles it
- NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
- NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”
5 compounds tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
- Chromium (total)
- Haloacetic acids (HAA5)
- Lead
- Nitrate
- Uranium
Violations since 2016
No health-based violations on file with EPA since 2016. EPA’s file runs to 2026 Q3, so a notice your utility sent since then may not be here yet.
What handles it
A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box.
- NSF/ANSI 53
Claim: Arsenic (Pentavalent)<=50 ppb Reduction
For: Arsenic
Other claims that cover it: Arsenic (III) (50 ppb influent level)
- NSF/ANSI 58
Claim: Arsenic (Pentavalent)<=50 ppb Reduction
For: Arsenic
Other claims that cover it: Arsenic (Pentavalent)<=300 ppb Reduction; Arsenic (V) (300 ppb influent level)
At the tap, or for the whole house?
These come with the water itself, so a whole-house system certified for the same claims treats every tap and shower. A filter at the tap treats drinking water for much less. How whole-house systems compare.
Filters with those claims on a certifier’s listing
Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money
Under-sink reverse osmosis
Five years: $549, household of 3, cartridges included
WQA listing: NSF/ANSI 58, checked Oct. 9, 2026
Certified for: Arsenic
Countertop reverse osmosis
Five years: $1,344, household of 3, cartridges included
Certified for: Arsenic
Brondell Capella RC250 Reverse Osmosis System
Under-sink reverse osmosis
Five years: $1,950, household of 3, cartridges included
Certified for: Arsenic
One more filter
Aquasana SmartFlow Reverse Osmosis (AQ-SFRO2)
Under-sink reverse osmosis
Five years: $2,917, household of 3, cartridges included
Certified for: Arsenic
What this report can’t tell you
Everything else. Arsenic, fluoride, total trihalomethanes (TTHM), chromium (total), haloacetic acids (HAA5), nitrate and uranium results here are Texas’s own from 2020 on, with EPA’s national file for 2012 to 2019. Harris County MUD 449’s own annual report, which it must send you every year, has the contaminants this page does not show.
Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.
What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.
Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; Texas’s results run from Aug. 7, 2020 to Jan. 22, 2026.
Testing your own tap
What to test for at your tap
- Lead and copper. Both come mostly from a building’s own service line, solder and faucets, so a utility’s numbers can’t tell you yours. Harris County MUD 449’s latest lead sampling in EPA’s records, 2022 to 2024, had a 90th percentile of 0 ppb across the homes it sampled. The action level is 15 ppb, dropping to 10 ppb in November 2027, and EPA’s health goal for lead is zero. About lead.
The 3 labs Texas certifies closest to the area Harris County MUD 449 serves, or a kit by mail
The 3 labs Texas certifies closest to the area Harris County MUD 449 serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.
R&C Joy, Inc.
Katy, TX · about 6 miles
Certified for bacteria
Eurofins EMLab P&K – Houston
Houston, TX · about 15 miles
Certified for bacteria
ALS Laboratory Group, Environmental Services Division – Houston, Texas
Houston, TX · about 19 miles
Certified for lead and copper
Or test by mail
Tap Score sells lab tests as kits you fill at your tap and mail back. The sample goes to Tap Score’s lab, not one near you, so check that Texas certifies it for the test you want.
Tap Score
- Lead and Copper Water Test, with a pH test strip: $55
- Essential City Water Test, 25 metals, 4 minerals, nitrate, fluoride, hardness and pH: $189
Return shipping included.
Tap Score says each kit ships to “an accredited laboratory” but doesn’t name it, so TapBuff can’t check it against Texas’s list.
Prices from Tap Score’s own store on Oct. 22, 2026.
What to do now
- Nothing here is above an EPA limit or health benchmarkIn EPA’s and Texas’s records for this utility. They don’t cover everything, which is why the next step matters.Every contaminant TapBuff tracks
- Get the utility’s own reportHarris County MUD 449 must send you a water quality report every year. It covers contaminants this page does not show.How to read it
- Test your own tap for leadIts latest lead sampling found none at the 90th percentile, but your own service line, solder and fixtures decide the lead at your faucet.Lead in your water: what to do
Sources
- EPA UCMR 5 occurrence data, file of Oct. 15, 2026
- EPA SDWA bulk download (SDWIS federal data), 2026 Q3
- Texas Commission on Environmental Quality, Texas Drinking Water Viewer, results from Jan. 7, 2020 to Oct. 6, 2026, read Oct. 16, 2026
- EPA Six-Year Review 4 compliance monitoring data, 2012 to 2019, file of Feb. 5, 2024
- Certified labs: TCEQ, drinking water laboratories approved for public water system samples, read Oct. 10, 2026; distances from the Census 2020 ZIP code tabulation area gazetteer
- Limits and goals: each contaminant’s page, with its EPA source.
- How this page is built: methodology.
PWSID TX1013372. Rebuilt from EPA data on Oct. 25, 2026.