Harleton WSC
EPA’s and Texas’s records have results for 38 contaminants in its water; 10 were found.
In the name, WSC means water supply corporation.
Serves 4,107 people · Surface water bought from another system · Harleton, TX
- Serves
- 4,107 people
- Connections
- 1,639
- Water source
- Surface water bought from another system
- Based in
- Harleton, TX
- County
- Harrison
- Owner
- Local government
The short answer
None of the results here is above a limit in force today. Lithium is above EPA’s health benchmark. 4 health-based violations since 2016, all resolved in EPA’s file.
This is what the records show, not medical advice. Worried about a health effect? Talk to a doctor or your local health department.
What was found
Where these results come from, and when
PFAS and lithium: EPA UCMR 5, samples taken from Feb. 13, 2023 to Feb. 17, 2026.
Haloacetic acids (HAA5), nitrate, total trihalomethanes (TTHM), fluoride, arsenic, chromium (total) and uranium: Texas’s own results, samples taken from March 16, 2020 to Sept. 2, 2026, with EPA’s 2012 to 2019 file for earlier years.
What the lines mean
- Legal limit (MCL):
- Enforceable. The most a utility may deliver.
- Health goal (MCLG):
- Not enforceable. The level with no expected risk, with a margin of safety.
- Health benchmark:
- A screening level EPA uses where there is no legal limit or health goal, not an enforceable limit.
- Health reference level:
- A screening level from EPA’s work on whether to regulate a contaminant, where there is no legal limit or health goal; not enforceable.
PFAS: PFBS was found, of the six PFAS in EPA’s 2024 drinking water rule; its result is below. Four other PFAS with no federal limit were found, the highest PFPeA at 164 ppt: see them below.
Above EPA’s health benchmark, 1 result
Lithium
Comes from the source
17.7 ppb
Highest sample, Nov. 14, 2023; found in 3 of 8
The highest sample was 17.7 ppb, above EPA’s health reference level of 10 ppb. That is a screening level, not an enforceable limit.
What handles it
No filter certification covers lithium yet, and EPA’s 2023 fact sheet says boiling doesn’t remove it. Because it was found, your utility has to report its lithium results in its annual water quality report, where newer ones will appear.
How to read your utility’s reportBelow EPA’s limits, 5 results
- Legal limit (MCL):
- Enforceable. The most a utility may deliver.
- Health benchmark:
- A screening level EPA uses where there is no legal limit or health goal, not an enforceable limit.
Haloacetic acids (HAA5), Legal limit 60 ppb; highest yearly average 11.8 ppb
Highest yearly average, 2020 to 2026 · Forms or is added in treatment
Averaged by year, the highest was 11.8 ppb, in 2026, below EPA’s legal limit of 60 ppb. Its highest single sample was 15.1 ppb. That was also the latest year on file.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest yearly average of 20.2 ppb, in 2018.
What handles it
No certification claim covers this compound yet.
Nitrate, Legal limit 10 ppm; highest 0.99 ppm
Highest sample; found in 12 of 13 · 2026 average: 0.1 ppm · Comes from the source
The highest sample, in 2025, was 0.99 ppm, below EPA’s legal limit of 10 ppm. In 2026, the latest year on file, its two samples averaged below the limit.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest sample of 0.44 ppm, in 2015.
What handles it
- NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
- NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”
Total trihalomethanes (TTHM), Legal limit 80 ppb; highest yearly average 7.4 ppb
Highest yearly average, 2020 to 2026 · Forms or is added in treatment
Averaged by year, the highest was 7.4 ppb, in 2026, below EPA’s legal limit of 80 ppb. Its highest single sample was 11.6 ppb. That was also the latest year on file.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest yearly average of 80.5 ppb, in 2018, and EPA recorded a violation in 2019.
What handles it
- NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
- NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”
Fluoride, Legal limit 4.0 ppm; highest yearly average 0.36 ppm
Highest yearly average, 2020 to 2026 · 2026, one sample: 0.28 ppm · Forms or is added in treatment
Averaged by year, the highest was 0.36 ppm, in 2020, below EPA’s legal limit of 4.0 ppm. In 2026, the latest year on file, its one sample was below the limit.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest yearly average of 0.5 ppm, in 2017.
What handles it
- NSF/ANSI 58 look for “Fluoride Reduction”
- NSF/ANSI 53 look for “Fluoride”
PFBS, Health benchmark 2,000 ppt; highest 4.8 ppt
Highest sample, Nov. 14, 2023; found in 1 of 8 · Comes from the source
The highest sample was 4.8 ppt, below EPA’s health benchmark of 2,000 ppt. PFBS has no legal limit or health goal of its own.
What handles it
- NSF/ANSI 53 look for “Total PFAS Reduction”
EPA’s 2024 PFAS rule, compound by compoundAll six, found or not, and the Hazard Index, against the rule’s limits.
| PFAS | EPA’s limit | Result |
|---|---|---|
| PFOA | 4.0 ppt | Not foundNot found in any of 8 samples, below 4 ppt |
| PFOS | 4.0 ppt | Not foundNot found in any of 8 samples, below 4 ppt |
| PFHxS | 10 ppt | Not foundNot found in any of 8 samples, below 3 ppt |
| PFNA | 10 ppt | Not foundNot found in any of 8 samples, below 4 ppt |
| HFPO-DA (GenX) | 10 ppt | Not foundNot found in any of 8 samples, below 5 ppt |
| PFBS | Index only | Below EPA’s limits4.8 ppt highest, found in 1 of 8 samples. Details |
| Hazard IndexPFHxS, PFNA, HFPO-DA and PFBS together | 1 | Doesn’t applyDoesn’t apply: no sampling location found two or more of the four |
| Results from EPA’s UCMR 5 sampling. “Below” is the lab’s reporting level: a result under it reads as not found, which is not the same as zero. The limits are EPA’s 2024 rule, with compliance due from 2029; EPA has since proposed changes to some of them, explained on each compound’s page. PFBS has no limit of its own and counts only toward the Hazard Index, which adds up the four, each against EPA’s health-based level, from each sampling location’s average, as EPA’s UCMR 5 summary does. It counts only where two or more of the four were found, and is above the limit from 1.5. | ||
Also found, with no federal limit
EPA measured these PFAS to learn how often they occur. None has a legal limit or a health goal yet.
| Compound | Highest sample | Found in | Certification claim |
|---|---|---|---|
| PFPeA | 164 ppt | 1 of 8 | None covers it |
| PFBA | 10 ppt | 1 of 8 | None covers it |
| PFHxA | 6.5 ppt | 1 of 8 | None covers it |
| 6:2 FTS | 6.3 ppt | 1 of 8 | None covers it |
28 compounds tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
From routine monitoring
- Arsenic
- Chromium (total)
- Lead
- Uranium
PFAS and lithium, from EPA’s UCMR 5 sampling
- 11Cl-PF3OUdS
- 4:2 FTS
- 8:2 FTS
- 9Cl-PF3ONS
- ADONA
- HFPO-DA (GenX)
- NEtFOSAA
- NFDHA
- NMeFOSAA
- PFDA
- PFDoA
- PFEESA
- PFHpA
- PFHpS
- PFHxS
- PFMBA
- PFMPA
- PFNA
- PFOA
- PFOS
- PFPeS
- PFTA
- PFTrDA
- PFUnA
Violations since 2016
4 health-based violations since 2016, 3 for TTHM and 1 for the Lead and Copper Rule Revisions. The latest began Oct. 17, 2024.
- Resolved:
- EPA’s file records a resolving action. The utility came back into compliance, the rule no longer applied, or no further action was needed.
- No fix on record:
- It records none. EPA’s own word for these is archived, addressed or unaddressed, shown beside each (EPA’s definitions, updated Oct. 9, 2026).
EPA’s file runs to 2026 Q3, so a notice your utility sent since then may not be here yet.
Got a notice about one? What it means and what to do| Contaminant or rule | What happened | Period, and what was measured | Status |
|---|---|---|---|
| Lead and Copper Rule Revisions | The required inventory of lead service lines was not completed or submitted on time.EPA: LSL Inventory | Oct. 17, 2024 | Resolved |
| TTHM | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | July 1, 2019 to Sept. 30, 2019, 82 ppb | Resolved |
| April 1, 2019 to June 30, 2019, 85 ppb | Resolved | ||
| Jan. 1, 2019 to March 31, 2019, 96 ppb | Resolved |
Health-based violations only. 15 monitoring or reporting violations not shown.
Disinfectant
Harleton WSC reported adding chloramine before water enters its pipes, at all 2 of its sampling points, in its 2023 to 2026 sampling for EPA.
What that means
Chloramine is chlorine combined with ammonia. It lasts longer in the pipes, and unlike chlorine, it doesn’t leave water that sits out. A filter’s chlorine claim doesn’t cover it: look for the separate chloramine claim under NSF/ANSI 42. No shower filter can carry one: NSF/ANSI 177, the shower filter standard, covers free chlorine only. Fish, turtles and frogs need it removed from their water. This utility buys its water from another system, so what it reported may leave out treatment done before the water reaches it. This is what the utility reported for that sampling. Its annual water quality report says what it uses now.
What this report can’t tell you
Everything else. Haloacetic acids (HAA5), nitrate, total trihalomethanes (TTHM), fluoride, arsenic, chromium (total) and uranium results here are Texas’s own from 2020 on, with EPA’s national file for 2012 to 2019. Harleton WSC’s own annual report, which it must send you every year, has the contaminants this page does not show.
Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.
What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.
Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 samples are from Feb. 13, 2023 to Feb. 17, 2026; Texas’s results run from March 16, 2020 to Sept. 2, 2026.
Testing your own tap
What to test for at your tap
- Lead and copper. Both come mostly from a building’s own service line, solder and faucets, so a utility’s numbers can’t tell you yours. Harleton WSC’s latest lead sampling in EPA’s records, 2026, had a 90th percentile of 0 ppb across the homes it sampled. The action level is 15 ppb, dropping to 10 ppb in November 2027, and EPA’s health goal for lead is zero. About lead.
- What Harleton WSC’s results flag: lithium. It is in the water the utility sends out, so a test of your tap mostly confirms it. Include it if you want a number for your own home.
The 3 labs Texas certifies closest to the area Harleton WSC serves, or a kit by mail
The 3 labs Texas certifies closest to the area Harleton WSC serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.
Southern Petroleum Laboratories (SPL), Inc. (FKA Ana-Lab Corporation)
Kilgore, TX · about 34 miles
Certified for bacteria, lead and copper
Environmental Monitoring Lab
Winona, TX · about 42 miles
Certified for bacteria
Northeast Texas Public Health District Laboratory
Tyler, TX · about 57 miles
Certified for bacteria
Or test by mail
Tap Score sells lab tests as kits you fill at your tap and mail back. The sample goes to Tap Score’s lab, not one near you, so check that Texas certifies it for the test you want.
Tap Score
- Lead and Copper Water Test, with a pH test strip: $55
- Essential City Water Test, 25 metals, 4 minerals, nitrate, fluoride, hardness and pH: $189
Return shipping included.
Tap Score says each kit ships to “an accredited laboratory” but doesn’t name it, so TapBuff can’t check it against Texas’s list.
Prices from Tap Score’s own store on Oct. 22, 2026.
What to do now
- Read up on lithiumWhat it does to health, where it comes from, and the certification claim that addresses it.About lithium
- Get the utility’s own reportHarleton WSC must send you a water quality report every year. It covers contaminants this page does not show.How to read it
- Test your own tap for leadIts latest lead sampling found none at the 90th percentile, but your own service line, solder and fixtures decide the lead at your faucet.Lead in your water: what to do
Sources
- EPA UCMR 5 occurrence data, file of Oct. 15, 2026
- EPA SDWA bulk download (SDWIS federal data), 2026 Q3
- Texas Commission on Environmental Quality, Texas Drinking Water Viewer, results from Jan. 7, 2020 to Oct. 6, 2026, read Oct. 16, 2026
- EPA Six-Year Review 4 compliance monitoring data, 2012 to 2019, file of Feb. 5, 2024
- Disinfectant: EPA UCMR 5 occurrence data, additional data elements, file of Oct. 15, 2026
- Certified labs: TCEQ, drinking water laboratories approved for public water system samples, read Oct. 10, 2026; distances from the Census 2020 ZIP code tabulation area gazetteer
- Limits and goals: each contaminant’s page, with its EPA source.
- How this page is built: methodology.
PWSID TX1020074. Rebuilt from EPA data on Oct. 25, 2026.