East Montgomery County MUD 4
What EPA’s and Texas’s records show in this utility’s water: nitrate, arsenic and other regulated chemicals; lead and copper; and violations since 2016, with the certification that handles each result.
- Serves
- 2,168 people
- Connections
- 884
- Water source
- Groundwater
- Based in
- Houston, TX
- County
- Montgomery
- Owner
- Local government
The short answer
1 result is above the health goal. The worst: Arsenic, above the health goal. No health-based violations on file since 2016.
What handles itWhat was found
Arsenic, fluoride, nitrate, chromium (total), haloacetic acids (HAA5), total trihalomethanes (TTHM) and uranium: Texas’s own results, samples taken from Oct. 8, 2020 to May 11, 2026, with EPA’s 2012 to 2019 file for earlier years.
Above the health goal1
Arsenic
Comes from the source
1.4ppb
Highest yearly average, 2022 to 2025
2025 average: 1.1 ppb
Averaged by year, the highest was 1.4 ppb, in 2022: below EPA’s legal limit of 10 ppb, but above its health goal of zero. Its highest single sample was 2.7 ppb. In 2025, the latest year on file, its two samples averaged 1.1 ppb.
What handles it
- NSF/ANSI 58 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
- NSF/ANSI 53 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
Below EPA’s limits2
Fluoride
Forms or is added in treatment
0.14ppm
Highest yearly average, 2020 to 2025
2025 average: 0.06 ppm
Averaged by year, the highest was 0.14 ppm, in 2020, below EPA’s legal limit of 4.0 ppm. In 2025, the latest year on file, its two samples averaged 0.06 ppm. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 0.21 ppm, in 2017.
What handles it
- NSF/ANSI 58 look for “Fluoride Reduction”
- NSF/ANSI 53 look for “Fluoride”
Nitrate
Comes from the source
0.05ppm
Highest sample; found in 2 of 14
2026: not found
The highest sample, in 2022, was 0.05 ppm, below EPA’s legal limit of 10 ppm. In 2026, the latest year on file, it wasn’t found in its one sample. Earlier, from 2012 to 2019, EPA’s file shows a highest sample of 0.03 ppm, in 2018.
What handles it
- NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
- NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”
5 compounds tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
- Chromium (total)
- Haloacetic acids (HAA5)
- Lead
- Total trihalomethanes (TTHM)
- Uranium
What handles it
A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box. Wording varies a little: NSF writes “Lead Reduction,” WQA just “Lead.”
- NSF/ANSI 53
Claim: Arsenic (Pentavalent)<=50 ppb Reduction
For: Arsenic
Other certifiers’ wording: Arsenic (III) (50 ppb influent level)
- NSF/ANSI 58
Claim: Arsenic (Pentavalent)<=50 ppb Reduction
For: Arsenic
Other certifiers’ wording: Arsenic (Pentavalent)<=300 ppb Reduction; Arsenic (V) (300 ppb influent level)
At the tap, or for the whole house?
These come with the water itself, so a whole-house system certified for the same claims treats every tap and shower. A filter at the tap treats drinking water for much less. How whole-house systems compare.
Filters with those claims on a certifier’s listing
Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money
Countertop reverse osmosis
- IAPMO listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 58NSF/ANSI 401checked Oct. 4, 2026
Certified for: Arsenic
Aquasana SmartFlow Reverse Osmosis (AQ-SFRO2)
Under-sink reverse osmosis
- WQA listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 58NSF/ANSI 401checked Oct. 9, 2026
Certified for: Arsenic
Brondell Capella RC250 Reverse Osmosis System
Under-sink reverse osmosis
- WQA listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 58NSF/ANSI 401checked Oct. 9, 2026
Certified for: Arsenic
Violations since 2016
No health-based violations on file with EPA since 2016.
What this report can’t tell you
Everything else. Arsenic, fluoride, nitrate, chromium (total), haloacetic acids (HAA5), total trihalomethanes (TTHM) and uranium results here are Texas’s own from 2020 on, with EPA’s national file for 2012 to 2019. East Montgomery County MUD 4’s own annual report, which it must send you every year, has the contaminants this page does not show.
Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.
What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.
Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; Texas’s results run from Oct. 8, 2020 to May 11, 2026.
Testing your own tap
The 3 labs Texas certifies closest to the area East Montgomery County MUD 4 serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.
Nova Biologicals, Inc.
Conroe, TX · about 18 miles
Certified for bacteria
Water Utility Services, Inc.
Spring, TX · about 20 miles
Certified for bacteria
Eastex Environmental Lab, Inc. -Coldspring
Coldspring, TX · about 30 miles
Certified for bacteria, lead and copper
Texas Well Owner Network, Texas A&M AgriLife Extension: Well Informed screening events, where well owners bring in water samples to be screened for common contaminants, followed by an hour-long session explaining the results. Upcoming events are on the network's calendar. Trainings, Texas Well Owner Network.
All 80 certified labs for TexasSources
- EPA UCMR 5 occurrence data, file of Oct. 15, 2026
- EPA SDWA bulk download (SDWIS federal data), 2026 Q3
- Texas Commission on Environmental Quality, Texas Drinking Water Viewer, results from Jan. 7, 2020 to Oct. 6, 2026, read Oct. 16, 2026
- EPA Six-Year Review 4 compliance monitoring data, 2012 to 2019, file of Feb. 5, 2024
- Certified labs: TCEQ, drinking water laboratories approved for public water system samples, read Oct. 10, 2026; distances from the Census 2020 ZIP code tabulation area gazetteer
- Limits and goals: each contaminant’s page, with its EPA source.
- How this page is built: methodology.
PWSID TX1700741. Rebuilt from EPA data on Oct. 18, 2026.
What to do next
- Read up on ArsenicWhat each one does to health, where it comes from, and the certification claim that addresses it.About Arsenic
- Get the utility’s own reportEast Montgomery County MUD 4 must send you a water quality report every year. It covers contaminants this page does not show.How to read it
- Test your own tap for leadYour service line, solder and fixtures decide the lead at your faucet, not the utility’s average.Lead in your water: what to do
- Compare certified filtersWhat the filters certified for these results cost over five years, cartridges included.Compare five-year costs