Skip to content
TapBuff

Devils Shores WSC

What EPA’s and Texas’s records show in this utility’s water: nitrate, arsenic and other regulated chemicals; lead and copper; and violations since 2016, with the certification that handles each result.

Serves
97 people
Connections
64
Water source
Groundwater
Based in
Del Rio, TX
County
Val Verde
Owner
Local government
The ZIP code it serves

78840

The short answer

2 results are above the health goal. The worst: Uranium, above the health goal. 2 health-based violations since 2016.

What handles it

What was found

Lead and copper: EPA SDWIS monitoring periods ending 1999 to 2026.

Uranium, nitrate, fluoride, total trihalomethanes (TTHM), arsenic, chromium (total) and haloacetic acids (HAA5): Texas’s own results, samples taken from May 7, 2020 to March 17, 2026, with EPA’s 2012 to 2019 file for earlier years.

Above the health goal2

Uranium

Comes from the source

Above the health goal

1.0ppb

Highest yearly average, 2021

Averaged by year, the highest was 1.0 ppb, in 2021: below EPA’s legal limit of 30 ppb, but above its health goal of zero. That is the only year on file. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 1.1 ppb, in 2015.

What handles it

Lead

Comes from pipes, often your own

Above the health goal

0.4ppb

90th percentile, 2026

In the latest period, 9 in 10 homes sampled were at or below 0.4 ppb, below EPA’s action level of 15 ppb. The action level drops to 10 ppb on Nov. 1, 2027. EPA’s health goal for lead is zero.

What handles it

Below EPA’s limits3

Nitrate

Comes from the source

Below EPA’s limits

2.2ppm

Highest sample; found in 7 of 7

2026, one sample: 1.7 ppm

The highest sample, in 2023, was 2.2 ppm, below EPA’s legal limit of 10 ppm. In 2026, the latest year on file, its one sample was 1.7 ppm. Earlier, from 2012 to 2019, EPA’s file shows a highest sample of 2.3 ppm, in 2016.

What handles it

  • NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
  • NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”

Fluoride

Forms or is added in treatment

Below EPA’s limits

0.24ppm

Highest yearly average, 2022 to 2025

2025: not found

Averaged by year, the highest was 0.24 ppm, in 2022, below EPA’s legal limit of 4.0 ppm. In 2025, the latest year on file, it wasn’t found in its one sample. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 0.26 ppm, in 2013.

What handles it

Total trihalomethanes (TTHM)

Forms or is added in treatment

Below EPA’s limits

2.5ppb

Highest yearly average, 2022 to 2025

2025: not found

Averaged by year, the highest was 2.5 ppb, in 2022, below EPA’s legal limit of 80 ppb. In 2025, the latest year on file, it wasn’t found in its one sample. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 7.0 ppb, in 2016.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”
3 compounds tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
  • Arsenic
  • Chromium (total)
  • Haloacetic acids (HAA5)

What handles it

A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box. Wording varies a little: NSF writes “Lead Reduction,” WQA just “Lead.”

At the tap, or for the whole house?

Lead and copper usually come from pipes and fixtures inside or near your home. A whole-house system sits where water enters, so it cannot catch what your own plumbing adds after it. For those, the filter that counts is the one at the tap. How whole-house systems compare.

Filters with those claims on a certifier’s listing

Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money

Compare five-year costs

The best water filters for lead, ranked

Violations since 2016

Contaminant or ruleTypePeriodMeasuredStatus
Lead and Copper RuleA required study or plan for corrosion control was not done on time.EPA: OCCT/SOWT Study/RecommendationApril 1, 2018—Resolved
Lead and Copper RuleA required study or plan for corrosion control was not done on time.EPA: OCCT/SOWT Study/RecommendationMarch 31, 2018—Resolved
Health-based violations only. Resolved and archived mean the utility returned to compliance or the state closed the record. 9 monitoring or reporting violations not shown.

What this report can’t tell you

  • Everything else. Uranium, nitrate, fluoride, total trihalomethanes (TTHM), arsenic, chromium (total) and haloacetic acids (HAA5) results here are Texas’s own from 2020 on, with EPA’s national file for 2012 to 2019. Devils Shores WSC’s own annual report, which it must send you every year, has the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; Texas’s results run from May 7, 2020 to March 17, 2026.

Testing your own tap

Devils Shores WSC’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab Texas certifies.

No lab Texas certifies is within 75 miles of the area Devils Shores WSC serves on the state’s list. Some take samples by mail; the state’s page lists them all.

Texas Well Owner Network, Texas A&M AgriLife Extension: Well Informed screening events, where well owners bring in water samples to be screened for common contaminants, followed by an hour-long session explaining the results. Upcoming events are on the network's calendar. Trainings, Texas Well Owner Network.

All 80 certified labs for Texas

Sources

PWSID TX2330021. Rebuilt from EPA data on Oct. 18, 2026.